, 32 Deep 25 Applicable tubing O.D.

Bore size (mm) Max. stroke Standard stroke (mm) 32 2560 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 40 2540 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 50 2520 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 2510 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 2430 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 100 2470 25, 50, 80, 100, 125, 160

25 Wide selection of piping For 2 piping!

1 Vacuum Pad: Ball Joint Type Series ZPT/ZPR Pad Diameter: 10, 13, 16, 20, 25, 32, 40, 50 ZX ZR ZM ZH ZU Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZL ZY on ti rp so on ad a ZQ sl or an l f ea te d ZF id wo pe rk ZP ty su nt ZCU oi rf ac l j AMJ al e s B Misc

Vacuum Pad: Ball Joint Type Series ZPT/ZPR Pad diameters: 10, 13, 16, 20 25, 32, 40, 50 rp ti on so ad on r sl fo a nt al e e d id w e or p ty k t s in u rf o j a ll c a e B s Series ZPT: Vertical vacuum entry type Series ZPR: Lateral vacuum entry type One-Touch fitting Vacuum Pad: Ball Joint Type Series ZPT/ZPR Pad diameters: 10, 13, 16, 20, 25, 32, 40, 50 Pad materials: NBR, Silicon rubber

(Note3) (1)Ambient temp. : 25, (2)Circulating fluid : Tap water, (3)Circulating fluid rated flow, (4)Power supply : 200 VAC. (Note4) (1)Ambient temp. : 25, (2)Circulating fluid : Tap water, (3)Circulating fluid temp. : CH1 : 20/CH2 : 25, (4)Circulating fluid rated flow, (5)Power supply : 200 VAC, (6)Piping length : Shortest, (7)Rated cooling load is applied.

1200 1 ,4QO , 80 25, 50, 7~ 100, 1 25, 150. 1 7~20~ 250,300, 350, 400,450.500, 600, 700, 800 100 1500 25, 50.75, 100, 125, 150,175,200, 250,300, 350,400,450,500,600,700,800 Intermediate strokes are available.

Applicable rotary actuator Applicable air gripper Size Page Size 30 50-100 10/15 20-100 10/15 20-40 32/40 1/3 7/20 10-200 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB CDRQ MRQ MDSUB MSQ MHZ2 MHZJ2 MHL2 MDHR MHS 12-25 MHK MHS MHC2 MHT2 MHW2 10-25 10/16 MHY MRHQ 2.11-8 D-A72/A73/A80 Grommet D-A72H/A73H D-A76H/A80H 2.11-9 Rail Connector 2.11-10 D-A73C/A80C D-A53/A54/A56

Lead wire color Dot marking 18 19 14 15 Pink 16 17 20 21 22 Pink 23 24 25 13 Terminal no.

M ai nt enance and i nspect i on Turn of f t he pow er suppl y, st op t he suppl i ed ai r, exhaust t he resi dual com pressed ai r and veri f y t he rel ease of ai r bef ore perf orm i ng m ai nt enance. Forei gn m at t er caught i n t he i nl et of pi pi ng or exhaust m ay i nt erf ere w i t h norm al operat i on. Peri odi c cl eani ng i s necessary.

I f suppl y pressure t o t hi s product i s i nt errupt ed or shut of f , w hi l e t he pow er i s st i l l on, t he i nt ernal sol enoi d val ve w i l l cont i nue t o operat e and a hum m i ng noi se m ay be generat ed. Si nce t he l i f e of t he product m ay be short ened, shut of f t he pow er suppl y al so w hen suppl y pressure i s i nt errupt ed or shut of f .

(page 66) Button The flow adjustment valve fails to adjust the flow 2 Flow adjustme nt valve Loosen the lock ring, and then adjust the flow adjustment valve.

If the operating temperature range is beyond ISO VG32, select ISO VG46 (suitable for 25 to 45C range). 1. Do not use the product near flames, or in equipment or machinery that exceeds an ambient temperatures of 60C. There is a danger of causing a fire because the air-hydro type uses a flammable hydraulic fluid.

Description Qty. 4 4 4 4 1 1 1 1 Seal Seal Seal Seal 10 10 10 10 1 1 1 1 Gasket Gasket Gasket Gasket Parts included in seal kit 11 11 11 11 1 1 1 1 Gasket Gasket Gasket Gasket 15 Wear ring 15 Wear ring 15 Wear ring 15 Wear ring 4 4 4 4 16 Piston seal 16 Piston seal 16 Piston seal 16 Piston seal 4 4 4 4 25 Seal washer 25 Seal washer 25 Seal washer 25 Seal washer 2 2 2 2 A set includes all

139 155 (10.5) 20 16.6 40 Bracket IZF21-m-mBmm 122 (104) 2 x 25 90 (155) 4 x 4.5 171.5 143 124 107 47 3 x 5.5 2 x 5.5 40 45 30 30 16 IZF21/31 Series Dimensions IZF31-m-m 4 x M4 x 0.7, depth 6 (Female thread mounting) 2 x 3.5, depth 1 144 55 25 12.5 179 195 36.6 (10.5) 20 40 Bracket IZF31-m-mBmm 162 (144) 90 2 x 25 (195) 4 x 4.5 211.5 163 144 47 148 3 x 5.5 40 2 x 5.5 45 45 45 17 Fan Type

= 0 25 (1/4)inch slroke) Reler to cala og N3O4 lor details and option compabbilily.

Ionizer IZS40/41/42 Series Potential amplitude: 25 V or less Rapid neutralization of static electricity: Fastest time: 0.1 seconds Note 2) Potential amplitude: 25 V or less RoHS Note 1) Note 1) IZS IZS Rapid neutralization of static electricity: Fastest time: 0.1 seconds Note 2) IZN IZF ZVB IZD IZE IZH Dual AC type IZS42 Series Potential amplitude of the workpiece is reduced with Dual AC

M ai nt enance and i nspect i on Turn of f t he pow er suppl y, st op t he suppl i ed ai r, exhaust t he resi dual com pressed ai r and veri f y t he rel ease of ai r bef ore perf orm i ng m ai nt enance. Forei gn m at t er caught i n t he i nl et of pi pi ng or exhaust m ay i nt erf ere w i t h norm al operat i on. Peri odi c cl eani ng i s necessary.

Applicable stroke table Stroke [mm] Size 30 50 100 150 200 250 300 350 400 450 500 Manufacturable stroke range 25 15 to 400 32 20 to 500 25 - .