SMC Corporation of America
Elite Part Number Search
Search Results "NCY2S25L-4000"

Outlet Air Temperature 50C 70C 100C Inlet air temperature (C) Correction factor Air flow (l/min (ANR)) Model 35.5 42.5 47.5 36 42.5 44 38.5 42.5 45 39 43 45 35 40 44 35.5 40 42 37 40 41.5 38 40 42 34.5 38 40 33 36.5 38 34 36 37 34 35 36 500 1000 1500 1000 2200 3000 2000 3300 4000 4000 5700 7000 HAA7 Air inlet Air outlet Air cooled style after cooler HAA15 HAA22 Auto-drain HAA37 Min.

Model A B C A B C A B C A B C 500 1000 1500 1000 2200 3000 2000 3300 4000 4000 5700 7000 34.5 38 40 33 36.5 38 34 36 37 34 35 36 35 40 44 35.5 40 42 37 40 41.5 38 40 42 35.5 42.5 47.5 36 42.5 44 38.5 42.5 45 39 43 45 HAA7 HAA15 HAA22 Maintenance HAA37 Caution 1. Inspect the cooler at least once a week and clean it to prevent it from becoming obstructed. 2.

CY320 Max. load weight (WBmax) (kg) Model CY3R15 CY3R20 CY3R25 CY3R32 CY3R40 1 2 3 4 5 6 7 8 9 1.0 1.1 1.2 1.5 2.0 CY315 0 Loading direction Load mounting surface 1000 2000 3000 4000 Stroke (mm) The above deflection data represent values at the time when the external sliding part moves to the middle of the stroke.

Delivery Pressure: N [25 to 4000 psig (0.17 to 27.6 MPa)], Relieving: 0 (Non Relieving), Connection 1: MV4 (1/4 Inch Face Seal, Male), Connection 2: MV4 (1/4 Inch Face Seal, Male), Gauge Port, Inlet: 40 [4000 psig (28 MPa)], Gauge Port, Outlet: 40 [4000 psig (28 MPa)], Pressure Gauge: psig/bar, Main Valve Seat Material: Vespel®, Standard, O-ring Material: Viton®, Standard, Flow Specification

Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves.  The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each. 

Serial interface unit EX120 controls up to 16 solenoid outputs and is compatible with series SV1000/2000/3000/4000, VQ1000/2000, SX3000/5000 and SY3000/5000 valves.

Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.

Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.

Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.

Serial interface unit EX120 controls up to 16 solenoid outputs and is compatible with series SV1000/2000/3000/4000, VQ1000/2000, SX3000/5000 and SY3000/5000 valves.

Serial interface unit EX120 controls up to 16 solenoid outputs and is compatible with series SV1000/2000/3000/4000, VQ1000/2000, SX3000/5000 and SY3000/5000 valves. 

W.S. 032767 032767 +0+32767 3276865535 -0-32767 -0-32767 15 V()50001000 4 V PLC 4000 -53No.EX-OMS0026CN (1) No.

(Data format: scale conversion format) E.O. set value W.S. set value Expected value 0 to 32767 0 to 32767 +0 to +32767 32768 to 65535 -0 to -32767 -0 to -32767 Example: To set the Fault Value to 4 V when the range is 1 to 5 V (analogue output range), scale upper limit 5000, and scale lower limit 1000, set 4000 to Fault Value using the PLC. -69No.EX-OMX1011 Analogue I/O unit parameters (1)

(Data format: scale conversion format) E.O. set value W.S. set value Expected value 0 to 32767 0 to 32767 +0 to +32767 32768 to 65535 -0 to -32767 -0 to -32767 Example: To set the Fault Value to 4 V when the range is 1 to 5 V (analogue output range), scale upper limit 5000, and scale lower limit 1000, set 4000 to Fault Value using the PLC. -66No.EX-OMZ0024 Analogue I/O unit parameters (1)

SI SI SMC PROFINET IO EX245 SI (1) IP65 (2) PROFINET IO (SCRJ) 2 (24V) 2 (3) 32 (4) 128 (5) 64 (6) 8 (7) (FSU) (8) CIRT (9) (MRP) (10) (11) (12) (13) SY3000 / 5000 / 7000 SV1000 / 2000 / 3000 VQC1000 / 2000 / 4000 / 5000 VSS8-2 / 8-4, VSR8-2 / 8-4 EX245 EX245-DX1 16 EX245-DY1 8 10 No.EX-OMU0020CN 1.2. 1.SI (EX245-SPN1) 2. (EX245-DX1) 3. (EX245-DY1) 5. 4.

4 V 5000 5 V (3)(5 V-1 V)(5000-1000)1/1000 15 V 1/1000 3000 AD 1000 5000 PLC (AD ) (ab) [V] [mA] 10 010 15 05 020 420 -32766 32767 10 5 5 20 20 -32767 32766 0 1 0 0 4 PLC : 032767 +0 +32767 PLC : 3276865535 -0 -32767 : 15 V 50001000 4VPLC 4000 -50No.EX-OMQ0015CN (1) [H.T.]

Correspondence table for scale upper or lower limit and output value at communication error (Data format: scale conversion format) Set value Expected value 0 to 32767 +0 to +32767 32768 to 65535 -0 to -32767 Example: To set the Fault Value to 4 V when the range is 1 to 5 V (analogue output range), scale upper limit 5000, and scale lower limit 1000, set 4000 to Fault Value using the GSDXML

configuration Flexible power supply combination Designed for use in safety systems up to SIL 3 according to EN 61508 Designed for use in safety systems up to Category 4, Performance level (PL) e according to EN ISO 13849 Choice of user selectable fail-safe operating modes (Channel Passivation or Module Passivation) Corresponding solenoid valve manifolds JSY3000/5000 SY3000/5000 VQC2000/4000

SI SI (Serial Interface)PROFIsafe/PROFINET IO SI EX245 SI IP65 PROFINET IO x2x2 EX245-FPS1:(24V)x2(SCRJ)x2 EX245-FPS2: (24V)x2(RJ45)x2 EX245-FPS3: 7/8 (5 )x2M12 (4 D code)x2 3 I/O 1 24 8 /1 x3 6 128 +8 64 8 US1 US2 EN61508 SIL3 ENISO13849 PLeCat.4 JSY3000/5000 SY3000/5000/7000 VQC2000/4000 I/O I/O SI : EX245-DX1(16 ) : EX245-DY1 (8 ) 14 No.EX##-OMY0006CN 3.2. 1.

A to B C to D 500 L 5 to 500 -25 to 525 L/min 1000 L 10 to 1000 -50 to 1050 2000 L 20 to 2000 -100 to 2100 PF2MC7 40 to 4000 -200 to 4200 500 L 0.17 to 17.66 -0.90 to 18.50 cfm 1000 L 0.35 to 35.31 -1.80 to 37.10 2000 L 0.70 to 70.63 -3.50 to 74.20 The flow ranges and relationship between the fluid and PD are shown in the figures below.