value OUT2 accumulated PLS1_L U8 0 Y 0: 100 (L/pulse) 1: 1000 (L/pulse) 1520 0x05F0 0 R/W 1530 0x05FA 0 R/W PLS1_Ft3 U8 0 Y 0: 1 (L/pulse) 1: 10 (L/pulse) 0: Add (Addition) 1: dEC1 AC (Setting of the accumulated flow output direction) Setting of the accumulated flow output direction 1600 0x0640 0 R/W U8 0 Y (Subtraction OUT1) 2: dEC2 (Subtraction OUT2) 0: 1.0 sec 1: 2.0 sec 2: 5.0 sec 1800
Y OUT2 setting (PLS/Err) 2ot (Selection of output type) Setting of OUT2 normal and reversed output U8 0 Y 0: 2_P (Normal output) 1: 2_n (Reverse output) 1540 0x0604 0 R/W Dir (Setting of the accumulated flow direction) 0: Add 1: dEC1 2: dEC2 Addition/Subtraction U8 0 Y 1600 0x0640 0 R/W 0: 1.0 sec 1: 2.0 sec 2: 5.0 sec 1 R/W FiL_FLoW (Digital filter_flow rate) U8 0 Y Set digital filter 1800
Initial value (dec) Remarks storage 2 CH1 CH2 CH3 CH4 Set the accumulated direction. 0: Add (Addition) 1: dEC (Subtraction OUT1) 2: dEC2 (Subtraction OUT2) AC (Accumulated display direction) 0x0640 (1600) 0x0641 (1601) 0x0642 (1602) 0x0643 (1603) 0 R/W Y U8 0x0 (0) Setting of digital filter. 0x0 ~ 0x0BB8 (0 ~ 3000) 0.01 s increment 0x070B (1803) 0 R/W FiL (Digital filter) Y U16 0x0 0x0708 (1800
(Page 84) SAVE (Accumulated flow value hold setting) 0: oFF (Not held) 1: 2.0 min 2: 5.0 min 1300 0x0514 0 R/W U8 0 Y 1800 0x0708 0 R/W diSP (Display OFF setting) U8 0 Y 0: on 1: oFF Pin (Security code Used/Not used) Security code U8 0 Y 0 :unused 1: use 1810 0x0712 0 R/W PinCode (Security code setting) Setting range 0x0 to 0x03E7 (0 to 999) 1811 0x0713 0 R/W U16 0 Y Line name 1st letter
(Page 86) SAVE (Accumulated flow value hold setting) 0: oFF (Not held) 1: 2.0 min 2: 5.0 min 1300 0x0514 0 R/W U8 0 Y 1800 0x0708 0 R/W dSP (Display OFF setting) U8 0 Y 0: on 1: oFF Pin (Security code Used/Not used) Security code U8 0 Y 0 :unused 1: use 1810 0x0712 0 R/W PinCode (Security code setting) Setting range 0x0 to 0x03E7 (0 to 999) 1811 0x0713 0 R/W U16 0 Y Line name 1st letter U8
Cooling capacity correction coefficient: Coefficient to calculate the cooling capacity at each altitude For the product operation at an altitude of 1800 meters, the cooling capacity = 8.4 Cooling Capacity x 0.8. Altitude [m] 1. Max. ambient 2. Cooling capacity temp.
Cooling capacity correction coefficient: Coefficient to calculate the cooling capacity at each altitude For the product operation at an altitude of 1800 meters, the cooling capacity = 8.4 Cooling Capacity x 0.8. Altitude [m] 1. Max. ambient 2. Cooling capacity temp.
Cooling capacity correction coefficient: Coefficient to calculate the cooling capacity at each altitude For the product operation at an altitude of 1800 meters, the cooling capacity = 9.4 Cooling Capacity x 0.8. Altitude [m] 1. Max. ambient 2. Cooling capacity temp.
Cooling capacity correction coefficient: Coefficient to calculate the cooling capacity at each altitude At an altitude of 1800 meters = Cooling capacity 8.4 x 0.8. Altitude [m] 1. Max. ambient 2. Cooling capacity temp.
Cooling capacity correction coefficient: Coefficient to calculate the cooling capacity at each altitude At an altitude of 1800 meters = Cooling capacity 8.4 x 0.8. Altitude [m] 1. Max. ambient 2. Cooling capacity temp.
An adjustable data buffer is available via OPC UA for up to 1800 bytes of data and a sampling rate of 100 ms or longer. Parameters Description Data buffer Enable or Disable The data buffer array can be enabled or disabled for each OPC UA node. Historical Data Buffer Sampling Cycle Sampling cycle time for the buffer.
Fluid: water 500 1400 Ambient 15C 1200 400 Cooling capacity W Cooling capacity W 1000 Ambient 15C 300 Ambient 35C 800 Ambient 20C Ambient 25C 600 200 400 Ambient 30C 100 200 0 0 10 15 20 25 30 35 40 45 50 10 15 20 25 30 35 40 45 50 Fluid temperature degC Circulating fluid temperature degC Fig. 6-1 Cooling capacity 2) Heating capacity Fluid: water Fluid: water 1000 2000 900 Ambient 35C 1800
LEMB / LEMC LEMH / LEMHT Speed [mm/s] Acceleration Speed [mm/s] Acceleration [mm/s2] [mm/s2] 0 48 250 48 250 1 75 500 75 500 2 100 1000 100 1000 3 150 1500 150 1500 4 200 2000 200 2000 5 250 2500 300 2500 6 300 3000 400 3000 7 350 4000 500 4000 8 400 5000 600 5000 9 450 6000 800 6000 10 500 7500 1000 7500 11 600 10 1200 10 12 700 12500 1400 12500 13 800 15000 1600 15000 14 900 17500 1800
3000 3000 0.7MPa Clamping force (N) Clamping force (N) 2500 2500 0.7MPa 2000 2000 1500 1500 0.5MPa 0.5MPa 1000 1000 0.3MPa 0.3MPa 500 500 0 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 Shim Shim thickness (mm) thickness (mm) 0.3MPa 0.3MPa Recommended shim thickness Recommended shim thickness 0.5MPa 0.5MPa 0.7MPa 0.7MPa 9 - Arm length L300mm 1800
Remark: Only when the air cylinder is intended for use outside Japan, products with 180 and 200 will be available as special order up to the stroke of 1800, and products with 250 and 320 will be as special order up to the stroke of 2000. Caution ! Cylinder should be operated within the max. usable stroke. Operation at the stroke beyond the max. stroke could cause breakage of piston rod.
190 x L440 190 x L770 Applicable model For FGFA For FGFB Specifications Model FGF1A-20 FGF1B-20 FGF3A-40 FGF3B-40 FGF5A-60 FGF5B-60 Material Polyester 5, 10, 25, 50, 100 m Differential pressure 0.1 MPa 3 elements included 1 element included Nominal filtration accuracy Element replacement differential pressure Element 5 elements included Number of elements Size Filtration area 190 x L440 1800
190 x L440 190 x L770 Applicable model For FGFA For FGFB Specifications Model FGF1A-20 FGF1B-20 FGF3A-40 FGF3B-40 FGF5A-60 FGF5B-60 Material Polyester 5, 10, 25, 50, 100 m Differential pressure 0.1 MPa 3 elements included 1 element included Nominal filtration accuracy Element replacement differential pressure Element 5 elements included Number of elements Size Filtration area 190 x L440 1800
W N 600 (1800) L 500 ML2B40 ML2B40 Caution If the cylinder mounting surfaces are not measured accurately, using a side support may cause poor operation. Therefore, be sure to level the cylinder tube when mounting.
Stroke adjusting unit Cylinder stroke (mm) Nil L H LH Without adjusting unit With low load shock absorber + Adjusting bolt With high load shock absorber + Adjusting bolt With one L unit and one H unit each 100, 200, 300, 400, 500, 600, 700 800, 900, 1000, 1200, 1400, 1600 1800, 2000 20, 25, 32, 40 50, 63 No stroke adjustment units are used for 50 and 63.
04-1 AL4000-06-1 AL5000-06 to 10-1 AL6000-10-1 1/4, 3/8 1/4, 3/8, 1/2, 3/4 3/4, 1 1 ( ): With float switch 1.17-7 Large Flow Lubricator Series AL800/900 Standard Specifications Individual lubrication Large flow style Model AL800 AL900 AC 4 1 1 Port size 2 1 1 2 AV Fluid Proof pressure Max. operating pressure Air 1.5MPa 1.0MPa AU AF 1 : 460 4 1 (1) Min. operating flow (l/min (ANR)) 2 1 1800