Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.12~1.0, Cushion: Rubber bumper at both ends, Port thread type: M5 x 0.8, Auto Switches:
Series: Standard w/ Magnet, Mounting: MF1, Front Flange, Bore Size: 1 1/2", Stroke: 6", Air Cushion / Rod Boot: No Cushion, Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 1m, Number: -, X Option: -
Compact Cylinder with Linear Guide, GUIDED CYLINDER
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, SLIDE TABLE, ACTUATOR, MXQ GUIDED CYLINDER, CE, 6MM MXQ DBL-ACT AUTO-SW, .66138 lb
Bore Size: 16mm, Action: S (Single Acting N.O.), Finger Position: Standard, Body Option: Basic, Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: M (1m), Number: 2 pcs. (Or None in the Case of No Switch), Made-to-Order: X5 (Fluororubber Seal)
Mounting: G (Head Flange), Bore Size: 50mm, Stroke: 75mm, Option: M (Rod End Male Thread), Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: M (1m), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Connector With Lead Wire), Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor
Mounting: G (Head Flange), Bore Size: 50mm, Stroke: 75mm, Option: M (Rod End Male Thread), Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: M (1m), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Connector With Lead Wire), Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Head-end flange
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches
Bore Size: 16mm, Action: Single Acting N.O., Finger Position: Standard, Body Option: Basic, Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 1m, Number: 2 pcs. (Or None in the Case of No Switch), Made-to-Order: Fluororubber Seal
Magnet: D (Built-in Magnet), Series: J2K, Mounting: M (Double Foot), Bore Size: 16mm, Stroke: 200mm, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: M (1m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: B (
Mounting: Head Flange, Bore Size: 50mm, Stroke: 75mm, Option: Rod End Male Thread, Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 1m, Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 24 VDC, Electrical Entry: M Plug Connector With Lead Wire, Surge Voltage Suppressor: Light/Surge Voltage Suppressor, Manual Override
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Head-end flange
Cylinder, Air, COMPACT CYLINDER W/LINEAR GUIDE, O14, 0.20000 lb
Dual rod cylinder, compact type, Slide bearing or ball bushing bearing, Bore size *: 6, 10, 15, 20, 25, 32, Standard strokes *: 10, 20, 30, 40, 50, 75, 100, Auto switches available, Made to Order additionally released. CXSJ COMPACT CYLINDER. 15MM CXSJ SLIDE BEARING. ACTUATOR. 15MM CXSJ SLIDE BEARING. 0.6095 lb. GM.
Cylinder, Air, COMPACT CYLINDER W/LINEAR GUIDE, O14, 0.41100 lb
The series is available in 12, 16, 20, 25, 32, 40, 50, 63, 80, and 100mm bore sizes. Non-rotating accuracy is 0.2 or less. Series CQM allows a workpiece to be mounted directly to the tooling plate.
The MY2 high precision guide cylinder is available in bore sizes 16mm, 25mm and 40mm. This series has been designed with a high precision single or double axis guide to create a compact, low profile cylinder. Maintenance has been simplified by allowing the cylinder to be detached without disturbing the guide unit and work piece.Mechanically joint rodless cylinder, High precision guide type
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, MHF2 GRIPPERS, FE, 12MM MHF2 DBL-ACT AUTO-SW, 0.62463 lb