SMC Corporation of America
Elite Part Number Search
Search Results "LLB4-3N-V1SF"

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: N (NPN Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)

Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: B (PNP, 2 Outputs), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)

Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)

Sensor Resolution: 30 μm, Stroke: 20mm, Actuator Cable Length: 3m, Controller: NPN Controller, I/O Cable Length: -, Controller Mounting: -

Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: NPN Output, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: None, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -

Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: None, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -

Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: None, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -

Rated Distance Range: 0.01 to 0.03mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: None, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -

Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: None, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -

Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: None, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -

Rated Distance Range: 0.01 to 0.03mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: None, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -

Number of stations: Triple, Option: No bracket, Detection distance(mm): 0.02 to 0.15, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: NPN 1 output, Unit specification for pressure values: With unit switching function, Cable: None