Regulator, Pressure Boosting Valve: Regulator, Regulator Type: Electropneumatic, Shape: One-Touch Coupling Type, Operating Environment: Standard, Compatible Fluid: Air, Exhaust Mechanism (Air Bleed): [Included] Yes, Reverse Flow Function (Relief): No, Supply Side Connection Type: [One-Touch] One-Touch (mm), Supply Side, Connection Diameter: Ø4, Control Side Connection Type: [One-Touch] One-Touch
Regulator, Pressure Boosting Valve: Regulator, Regulator Type: Electropneumatic, Shape: One-Touch Coupling Type, Operating Environment: Standard, Compatible Fluid: Air, Exhaust Mechanism (Air Bleed): [Included] Yes, Reverse Flow Function (Relief): No, Supply Side Connection Type: [One-Touch] One-Touch (mm), Supply Side, Connection Diameter: Ø4, Control Side Connection Type: [One-Touch] One-Touch
Regulator, Pressure Boosting Valve: Regulator, Regulator Type: Electropneumatic, Shape: One-Touch Coupling Type, Operating Environment: Standard, Compatible Fluid: Air, Exhaust Mechanism (Air Bleed): [Included] Yes, Reverse Flow Function (Relief): No, Supply Side Connection Type: [One-Touch] One-Touch (mm), Supply Side, Connection Diameter: Ø4, Control Side Connection Type: [One-Touch] One-Touch
Connection Type: Screw⇔Screw Connection, Connection screw: M, Thread-to-Thread Connection Shape: [Male Straight] Nipple, Gasket Material: PVC, Made to Order Specifications: N/A
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: N (NPN Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)
Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: B (PNP, 2 Outputs), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)
Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)
Sensor Resolution: 30 μm, Stroke: 20mm, Actuator Cable Length: 3m, Controller: NPN Controller, I/O Cable Length: -, Controller Mounting: -
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: NPN Output, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: None, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: None, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -