SMC Corporation of America
Elite Part Number Search
Search Results "LEY32DEA-250-MN-X8"

Rated Flow Range: 3 (5 to 200 L/min), Output Specifications: B (OUT 1: PNP; OUT 2: PNP; Integrated Display Type), Port Size: 8 (1; Applicable to LFE3), Thread: N (NPT), Option: Lead Wire w/M12 Connector; L/min Unit Specification, Insulation Type: Z (Piping Port is Insulated with the Power Supply), Piping Connection: X8 (Stainless Steel 304)

Rated Flow Range: 1 (0.5 to 20 L/min), Output Specifications: F (OUT 1: PNP; OUT 2: Analog 4 to 20 mA; Integrated Display Type), Port Size: 3 (3/8; Applicable to LFE1), Thread: N (NPT), Option: Lead Wire w/M12 Connector; L/min Unit Specification, Insulation Type: Z (Piping Port is Insulated with the Power Supply), Piping Connection: X8 (Stainless Steel 304)

Rated Flow Range: 1 (0.5 to 20 L/min), Output Specifications: A (OUT 1: NPN; OUT 2: NPN; Integrated Display Type), Port Size: 4 (1/2; Applicable to LFE1), Thread: Rc, Option: Lead Wire w/M12 Connector; L/min Unit Specification, Insulation Type: Z (Piping Port is Insulated with the Power Supply), Piping Connection: X8 (Stainless Steel 304)

Rated Flow Range: 2 (2.5 to 100 L/min), Output Specifications: D (OUT 1: NPN; OUT 2: Analog 4 to 20 mA; Integrated Display Type), Port Size: 6 (3/4; Applicable to LFE2), Thread: N (NPT), Option: 1 (L/min Unit Specification), Insulation Type: Z (Piping Port is Insulated with the Power Supply), Piping Connection: X8 (Stainless Steel 304)

Grommet L plug connector Manifold block Nil MN With manifold block None M plug connector Vacuum switch Note) For types LN and MN, the single solenoid has 2 sockets and the double solenoid has 3 sockets.

Wn Mass mn X-axis Xn Y-axis Yn Z-axis Zn Z X Wa 0.88kg 65mm 0mm 5mm 111 Wb 4.35kg 150mm 0mm 42.5mm Y 210 Y Wc 0.795kg 150mm 111mm 42.5mm Wd 0.5kg 150mm 210mm 42.5mm n = a, b, c, d 3 Calculation of composite center of gravity m = mn = 0.88 + 4.35 + 0.795 + 0.5 = 6.525kg 1 m X = x (mn x xn) 1 6.525 = (0.88 x 65 + 4.35 x 150 + 0.795 x 150 + 0.5 x 150) = 138.5mm 1 m Y = x (mn x yn) 1 6.525

VJ100M1.7 x 15 VJ300M1.7 x 22 Note) In the case of ZX1VJ114, M, MN and MO cannot be used. 13-2-7 7 Series ZX Ejector Unit Specifications 1 2 ZX1-W07 1 2 ZX1-W10 1 2 Unit no. ZX1-W05 0.5 5 13 Nozzle dia.

MO Grommet L type plug connector Max. vacuum pressure -84kPa {-630mmHg} -53kPa {-400mmHg} S L M type plug connector Nozzle diameter 07 10 0.7mm 1.0mm Note 1) Types LN and MN are equipped with sockets (2pcs.).

LN: Without lead wire LO: Without connector MO: Without connector + + "LN", "MN" type: with 2 sockets. 640 A 3 port solenoid valve 10-V100 How to Order Air cylinder Rotary actuator Air gripper Directional control valve Fittings & Tubing Pressure switch Clean gas filter Flow control equipment Filter, Pressure control equipment Air preparation equipment Large flow type Base mounted 5 10 V1

: Without lead wire L P B: Locking slotted type E: Push-turn locking lever type H: 600 mm lead wire LN: Without lead wire LO: Without connector MO: Without connector L P 1 4632 LN and MN types are with 2 sockets.

: Without lead wire H: 600 mm lead wire ++ ++ LN: Without lead wire LO: Without connector MO:Without connector + LN and MN types are with 2 sockets. 4-2-5 6 Series V100 Base Mounted (With sub-plate) Note) [ ]: values for large flow type (A).

Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4 220 VAC, 50/60 Hz G: Grommet, Lead wire length 300 mm L: L plug connector, With lead wire LN: L plug connector, Without lead wire LO: L plug connector, Without connector 5 24 VDC 6 12 VDC 9 Other Option D: DIN terminal M: M plug connector, With lead wire MN

Electrical entry 24, 12, 6, 5, 3 VDC Grommet L plug connector M plug connector G: Lead wire length 300 mm H: Lead wire length 600 mm L: With lead wire (Length: 300 mm) LN: Without lead wire LO: Without connector M: With lead wire (Length: 300 mm) MN: Without lead wire MO: Without connector * LN and MN types are with 2 sockets. * Refer to page 1737 for the different lead wire lengths of L

: Without lead wire L P B: Locking slotted style E: Push-locking lever style H: 600mm lead wire LN: Without lead wire LO: Without connector MO: Without connector L P 1 0 LN or MN option includes 2 sockets.

M2E M3 mn x g M1E mn x g M3E 1 3 x FE x Y M3E FE FE Note) Regardless of the mounting orientation, dynamic moment is calculated with the formulae above.

: Without lead wire D: With connector W0: Without connector cable M: Common exhaust for the pilot and main valve + + + + + R port P, E port H: Lead wire length 600 mm LN: Without lead wire LO: Without connector MO: Without connector DO: Without connector R: External pilot style -+ LN, MN type: with 2 sockets.

suppressor Electrical entry for G, H, L, M, W Electrical entry for D + + Nil Without light/surge voltage suppressor S Z With surge voltage suppressor With light/surge voltage suppressor R With surge voltage suppressor (Non-polar type) U With light/surge voltage suppressor (Non-polar type) Nil Without light/surge voltage suppressor S Z 24, 12, 6, 5, 3 VDC With surge voltage suppressor LN, MN

LN, MN type: with 2 sockets. For connector cable of M8 connector, refer to page 67. Note) When placing an order for body ported solenoid valve as a single unit, mounting bolt for manifold and gasket are not attached. Order them separately, if necessary. (For details, refer to page 8.) 3 Series SYJ300 Construction (A) 2 (A) 2 N.C.