(Equivalent to IP44) 90C 47C (50C) or less Splashproof/ Low jetproof type (JIS C 0920) 35C (40C) or less 100C Note) ( ) For IF32 To protect the microswitch, ambient temperature must be lowered when the fluid temperature exceeds 70C.
Thread type Nil Rc N NPT* * Semi-standard Suffix Low temperature (30 to 60C) High temperature* (10 to 100C) External parts copper-free Nil T V L V S V ST V V SL V V * With pressure gauge type: Max. 80C.
Although the variation in the operating range differs with the cylinder on which the auto switch is mounted, a temperature change of 100C will roughly result in the maximum of 20% reduction in the overall operation range.
High purity chemical valve, threaded type; Pilot port size: 1/8"; Fluid temperture: 0 to 100C; Body material: New PFA, PPS, Stainless Steel
Table Accuracy: H (High Precision), Size: 30, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: R (Robotic Type Cables, Flexible Type), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: CP1 (JXCP1, PROFINET), I/O Cable Length for LEC: w/o Cable
Table Accuracy: H (High Precision), Size: 50, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: R (Robotic Type Cables, Flexible Type), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: CP1 (JXCP1, PROFINET), I/O Cable Length for LEC: w/o Cable
Table Accuracy: High Precision, Size: 30, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 5, Controller Type - LEC, JXC: JXCP1, PROFINET, I/O Cable Length for LEC: w/o Cable, Controller Option:
Table Accuracy: High Precision, Size: 50, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 5, Controller Type - LEC, JXC: JXCP1, PROFINET, I/O Cable Length for LEC: w/o Cable, Controller Option:
Size: 25, Motor Mounting Position: D (In-line), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 150mm, Motor Option: C (w/Motor Cover)
Size: 25, Motor Mounting Position: D (In-line), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 300mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included)
Size: 25, Motor Mounting Position: D (In-line), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 100mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included)
Size: 25, Motor Mounting Position: In-line, Lead: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 150mm, Motor Option: w/Motor Cover, Rod End Thread: -, Mounting: -, Actuator Cable Type, Length: -, Controller: -, Mounting: -, I/O Cable: -, Communication Plug Connector: -
Size: 25, Motor Mounting Position: In-line, Lead: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: w/Motor Cover, Rod End Thread: Rod End Male Thread, 1 Rod End Nut is Included, Mounting: -, Actuator Cable Type, Length: -, Controller: -, Mounting: -, I/O Cable: -, Communication Plug Connector: -
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Size: 25, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: D (In-line), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: R5 (5m), Controller: CP1 (PROFINET), Mounting: 7 (Screw Mounting)
Size: 25, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: D (In-line), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: C (w/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: R5 (5m), Controller: CP1 (PROFINET), Mounting: 7 (Screw Mounting)
SMC's series LER electric rotary table is available in a basic or high precision style, and features a low profile, space-saving design. A digital control allows easy setting of the angular speed, and angular acceleration/deceleration, etc. Rotation angle is possible up to 320° (310° on LER10). Up to 6.6 N·m of rotation torque (3.3 N·m of pushing torque available). The rotation speed
Series: LEKFS, Size: 16, Motor Mounting Position: R (Right Side Parallel), Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 500, Motor Option: w/o Option, Seal Band Stopper: Standard, Actuator Cable Type, Length: R5 (5), Controller: CP1 (JXCP1, PROFINET, Direct Input Type), Controller Mounting: 7 (Screw Mounting
Series: LEFS, Accuracy: Basic Type, Size: 25, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 100mm, Motor Option: B (w/Lock), Auto Switch Compatibility: None, Grease Application: With, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type, Length: R5 (5m), Controller: