x 0.5 thread depth 7 (Mounting thread) 3 28.3 3.4 36 32 2 x M3 x 0.5 thread depth 4 15.8 22 (Mounting thread) 5.9 E 11 11 14 19 E 2 x 2.6 through (Mounting hole) M3 x 0.5 Finger opening port M3 x 0.5 0 0.1 17 12 12 Finger closing port 2 x 4.5 0.8 0.8 E-E +0.1 0 Close: 0 Open: 81 Use the attached hexagon socket head screws for mounting holes. 4 x M3 x 0.5 thread depth 4 (Mounting thread)
mounting attachment) M3 x 0.5 (Finger closing port) Auto switch mounting groove (2 positions) Adjustment needle for finger speed 11.6 3 9.4 S 4 6 0 0.05 4 7 7 Note) For single acting, one port is used as a breather port. 2.3 17.5 M3 x 0.5 (Finger opening port) MHKL2-12: Long stroke type 9 2-M3 x 0.5 thread depth 5 (Mounting thread) 20 3H9 depth 3 +0.025 0 13H9 depth 1.5 +0.043 0 2-M3 x 0.5
17.5 M3 x 0.5 (Finger opening port) MHKL2-12: Long stroke type 9 2-M3 x 0.5 thread depth 5 (Mounting thread) 20 3H9 depth 3 +0.025 0 13H9 depth 1.5 +0.043 0 2-M3 x 0.5 thread depth 6 (Mounting thread) 4-M4 x 0.7 thread depth 8 (Mounting thread) Bottom hole 3.4 through (Mounting hole) 0 0.1 5 Open 20 +1.2 0 4 8 10 0.02 41.6 30 20 3 22 43 0 0.2 Closed 9 26 3H9 depth 3 +0.025 0 15 36 13 57
for mounting attachment) M3 X 0.5 (Finger closing port) Groove position for auto switch mounting (2 positions) Adjustment needle for finger speed 11.6 3 9.4 S 4 6 0 -0.05 4 7 7 Note) For single acting, one port is used as bleed port. 2.3 17.5 M3 X 0.5 (Finger opening port) MHKL2-12l/Long stroke model 9 20 2-M3 X 0.5 thread depth 5 (Mounting thread) 3H9 depth 3 +0.025 0 2-M3 X 0.5 thread
X 0.5 thread 4 deep 15 3H9 3 deep +0.030 0 2-M3 X 0.5 thread 6 deep 13H9 1.5 deep +0.043 0 4-M4 X 0.7 thread 8 deep Bottom hole dia. 3.4 through-hole 0 -0.1 5 Open 13 +1.2 0 4 8 10 0.02 32.6 28 34 22 20 0 -0.2 Closed 9 22 3H9 3 deep +0.030 0 15 31 13 63 20 0.05 Groove position for auto switch mounting 4-M3 X 0.5 (Attachment mounting thread) M3 X 0.5 (Finger closing port) Groove position
How to replace the shock absorber 1) Loosen the hexagon socket head set screw (M3) on the piston rod.
Mount the sensor head using two M3 screws (not supplied with the product). Do not pull the cable connected to the sensor head. Pulling the cable with excessive force may cause sensor head breakage or wire breakage. 2) Installation of sensor amplifier Mount the sensor amplifier using two M3 screws (not supplied with the product). Do not pull the cable connected to the sensor amplifier.
) 7 2-2H9 +0.025 0 depth 2 3 3 7 11 11 Groove for auto switch mounting 2-M3 x 0.5 thread depth 4 Mounting thread 11 34 12-3-13 14 Series MHF2 Dimensions MHF2-8D2 2.5H9 +0.025 0 depth 2.5 17 17 17 2.5H9 +0.025 0 depth 2.5 3 3.4 64.3 4-M3 x 0.5 thread depth 7 Mounting thread 32 72 2-M3 x 0.5 thread depth 4 Mounting thread 15.8 58 5.9 E 11 11 14 19 E 0 -0.1 4-2.6 through (Mounting hole) M3 x
4-M3 x 0.5 thread depth 7 Mounting thread 32 72 2-M3 x 0.5 thread depth 4 Mounting thread 15.8 58 5.9 E 11 11 14 19 E 0 -0.1 4-2.6 through (Mounting hole) M3 x 0.5 17 18 0.8 18 0.8 Finger closing port M3 x 0.5 4-4.5 +0.1 0 Finger opening port Close: 0 E-E Open: 321 Use the attached hexagon socket head screws for mounting holes. 8-M2.5 x 0.45 thread depth 3 Attachment mounting thread 4-M3
) 258-9200-www.stevenengineering.com (3-NPT1/4) 3-Rc1/4 M5 x 0.8 Pilot port Breathing port M3 x 0.5 PB 13 46 PA 72 41 22.5 30 6.5 52.5 2-M5 x 0.8 Depth 6 20 17-5-26 24 Manually Operated Series LVH How to Order Valve (Single Type) VC Applicable tubing size Body class Body class 2 3 4 Connecting tubing O.D.
nickel plated Round head combination screw M3 x 31, Matt nickel plated Blanking plate SYJ700-10-2 Gasket SYJ700-5-1 Gasket Gasket SYJ700-5-3 SYJ700-5-4 Applicable base Sub-plate SS3YJ7-40 SS3YJ7-41 SS3YJ7-42 SS3YJ7-41R SS3YJ7-42R Applicable base SS3YJ7-20 SS3YJ7-21 SS3YJ7-21R Manifold base Manifold base Caution Mounting screw tightening torques M3: 0.8 Nm Use caution to the assembly orientation
Put a hexagon socket head cap screw (M3 x 0.5 x 14 L) through the auto switch's through-hole (2 locations), and then push it down into the M3 tapped part on the auto switch mounting bracket while turning it lightly. 3.
x 0.5 0.39 0.10 0.59 [0.40] 0.43 [0.33] 0.16 [0.11] 0.36 54 (28) 3 position 0.42 [0.33] 0.16 [0.080] 0.46 0.32 0.11 0.58 [0.32] 22 25 2 position SYJA320-M3 M3 x 0.5 M3 x 0.5 0.9 28 3 position 22 25 2 position SYJA330 M3 x 0.5 Note 1) Value when used on a manifold.
D-G79, D-K79, D-K79C Cover Auto switch mounting screw M3 x 0.5 x 6l Auto switch Auto switch Auto switch Auto switch mounting screw M4 x 0.7 x 22l Auto switch mounting screw M3 x 0.5 x 14l Auto switch mounting band (with bracket) Cylinder tube Auto switch mounting band (with bracket) Auto switch mounting band (with bracket) 1.
21.5 28 34 41 6 6 6 8 16 21 25 30 6.3 12 10.3 18 7 10 11.5 14 3/16 3/16 +0.002 0 +0.002 0 +0.002 0 +0.002 0 +0.002 0 +0.002 0 #8-32UNC 3/16 3/16 #10-32UNF 5/16 5/16 1/4-28UNF 3/8 3/8 Knuckle pin and snap ring are contained.
LEHS32 LEHS40 LEHS10(L) LEHS20(L) LEHS32 LEHS40 M3 x 0.5 0.9 M3 x 0.5 0.9 5. Do not use the product in applications where excessive external force (including vibration) or impact force is applied to it. It may lead to breakage or galling, which causes operation failure. Do not apply impact and vibration outside of the specifications.
Av = Q (8) P Av : Flow coefficient [m2] Q : Flow rate [m3/s] P : Pressure difference [Pa] : Fluid density [kg/m3] (3) Formula of flow rate It is described by the practical units. Also, the flow-rate characteristics are shown in Graph (2).