), 1.5 W DC (63 mA) , 0.5 W DC (21 mA) 24 VDC (3) (4) 3 position exhaust center 1 W DC (83 mA), 1.5 W DC (125 mA) , 0.5 W DC (42 mA) 12 VDC Power consumption (Current) Inrush 0.5 VA (5 mA), Holding 0.5 VA (5 mA) 100 VAC Start-up 0.55 VA (5 mA), Holding 0.55 VA (7.5 mA) 110 VAC Inrush 1.0 VA(5 mA), Holding 1.0 VA (5 mA) 200 VAC Inrush 1.1 VA (5 mA), Holding 1.1 VA (5 mA) 220 VAC 3 position
), 0.5 W DC (21 mA) 3 position exhaust center 12 VDC 1 W DC (83 mA), 0.5 W DC (42 mA) 2 position double (Metal) (A) 4 (B) 2 (A) 4 (B) 2 100 VAC Inrush 1.2 VA (12 mA), Holding 1.2 VA (12 mA) Power consumption (Current) 110 VAC Inrush 1.3 VA (11.7 mA), Holding 1.3 VA (11.7 mA) 1 (P) 5 (R1) 3 (R2) 200 VAC Inrush 2.4 VA (12 mA), Holding 2.4 VA (12 mA) 1 (P) 5 (R1) 3 (R2) 220 VAC Inrush 2.6 VA
2.5 to 40 mA 40 mA or less Load current 4 V or less 0.8 V or less at 10 mA (2 V or less at 40 mA) Internal voltage drop 0.8 mA or less 100 A or less at 24 VDC Leakage current Operating position . . . . .
), 1.5 W DC (63 mA) (3), 0.5 W DC (21 mA) (4) 24 VDC 1 W DC (83 mA), 1.5 W DC (125 mA) (3), 0.5 W DC (42 mA) (4) 12 VDC 100 VAC Inrush 0.75 VA (7.5 mA), Holding 0.75 VA (7.5 mA) Power consumption (Current) Rubber seal 110 VAC Inrush 0.83 VA (7.5 mA), Holding 0.83 VA (7.5 mA) 200 VAC Inrush 1.0 VA (5 mA), Holding 1.0 VA (5 mA) 3 position closed center 220 VAC Inrush 1.1 VA (5 mA), Holding
Maximum operating pressure Minimum operating pressure Response time 79.8 psi (0.55 MPa) 0 psi (0 MPa) ON: 3.5 ms OFF: 2 ms 1 W (42 mA) 1 W (42 mA) 79.8 psi (0.55 MPa) 14.5 psi (0.1 MPa) 5 ms or less 0.7 W (29 mA) Note 2) 14.5 psi (0.1 MPa) 14.5 psi (0.1 MPa) 5 ms or less 0.7 W (29 mA) Note 2) 79.8 psi (0.55 MPa) 14.5 psi (0.1 MPa) 5 ms or less 1 W (42 mA) 1 W (83 mA) 24 VDC 12 VDC Rated coil
28 VDC or less 2.5 to 40 mA 40 mA or less Load current 4 V or less 0.8 V or less at 10 mA (2 V or less at 40 mA) Internal voltage drop 100 A or less at 24 VDC 0.8 mA or less Leakage current Operating range .
), 0.5 W DC (21 mA) (3) 24 VDC 1 W DC (83 mA), 0.5 W DC (42 mA) Note (3) 12 VDC 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Inrush 1.2 VA (12 mA), Holding 1.2 VA (12 mA) 100 VAC Power consumption (Current) 3 position pressure center 2 position double (Metal) Inrush 1.3 VA (11.7 mA), Holding 1.3 VA (11.7 mA) 110 VAC (A) 4 (B) 2 (A) 4 (B) 2 Inrush 2.4 VA (12 mA), Holding 2.4 VA (12 mA) 200 VAC
), 0.95 W DC (40 mA) Note 3) Power consumption (Current) 12 VDC 0.4 W DC (34 mA), 0.95 W DC (80 mA) Note 3) Note 1) Use dry air to prevent condensation when operating at low temperatures.
), 0.5 W DC (21 mA) 24 VDC 12 VDC Power consumption (Current) 1 W DC (83 mA), 0.5 W DC (42 mA) Note 1) Use dry air to prevent condensation at low temperatures.
SMC website: https://www.smcworld.com 172 a JXCE1/91/P1/D1/L1/M1 Series Specifications Model JXCE1 JXC91 JXCP1 JXCD1 JXCL1 JXCM1 Network EtherCAT EtherNet/IP PROFINET DeviceNet IO-Link CC-Link Compatible motor Step motor (Servo/24 VDC) Power supply Power voltage: 24 VDC 10% Current consumption (Controller) 200 mA or less 130 mA or less 200 mA or less 100 mA or less 100 mA or less 100 mA
= 25 x n + 106 L1 L2 Terminal mounting stations are not included.
48 VAC, DC: 40 mA 100 VAC, DC: 20 mA Non plug-in type Note 1) Combining valve VFR41 (single) and release valve spacer makes it possible to use this as an air release valve.
mA Residual voltage: 2 V or less Max. 28 V, 80 mA Residual voltage: 2 V or less pe: 1 to 5 V e: Approx. 1 k B C A B C A Coil + + Max. 80 mA Residual voltage: 2 V or less Max. 28 V, 80 mA Residual voltage: 2 V or less pe: 1 to 5 V e: Approx. 1 k Black For supply valve (,+) Black For supply valve (,+) Coil White White Pilot valve for release Pilot valve for release LED (Red) Black LED For
L1 With coil scraper: C(D)Q2D-XC26C35 Spatter resistant specification for arc welding: CDQ2D-XC26C88/C89/C91 Th9 L2 (L) (A + Stroke) [mm] Bore size Stroke range XC35/XC91 XC88/XC89 A L L1 L2 Th9 A L L1 L2 Th9 Without magnet for auto switch Built-in magnet for auto switch Built-in magnet for auto switch 32 50 or less 116 126 51 33.5 5 23 0 0.052 131 56 38.5 10 23 0 0.052 75, 100 126 40 50
48 VAC/DC: 40 mA 100 VAC/DC: 20 mA VS4 Max. switch capacity Note 1) Voltage: 24 VDC to 100 VAC Inner voltage drop: 4 V Note 2) Combination of a valve VFS41 (single) and a release valve spacer can be used as an air release valve.
Mr = 0.2 x 9.8 (20 + 6.8)/1000 = 0.053 Ma = Mmax Find the allowable static moment Ma (Nm).
LECSB1/LECSC1/LECSS1: Single phase 100 to 120 VAC, 50/60 Hz Connection terminal: L1,L2 LECSB2/LECSC2/LECSS2: Single phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1,L2 Three phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1,L2,L3 Do not connect. L1 Main circuit power supply L2 L2 L3 L3 N P1 P2 N Connect between P1 and P2. (Connected at time of shipping.)
LECSB1/LECSC1/LECSS1: Single phase 100 to 120 VAC, 50/60 Hz Connection terminal: L1,L2 LECSB2/LECSC2/LECSS2: Single phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1,L2 Three phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1,L2,L3 Do not connect. L1 Main circuit power supply L2 L2 L3 L3 N P1 P2 N Connect between P1 and P2. (Connected at time of shipping.)
Display function Operating indicator light (Lights ON), Deviation level indicator light Power supply voltage 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With power supply polarity protection) Current consumption 30 mA or less (Output ON, All LEDs ON) ISA11 NPN open collector: 30 V, 80 mA or less Switch output ISA15 PNP open collector: 80 mA or less Operating temperature range 0 to 60C (No
L2 L2-10.5 L1=(28 x n)+56 18 20 28 28 5.3 28 5.5 84 SMC SMC SMC SMC 8 52.5 39 3 5 11.5 6 L2 dimension DIN rail part no.