*1: To use the power of the device, the total load current must be 500 mA or less.
(f) B u L-~ __~~__~~~ ~ Operating piston speed in/s (mm/s) ...J Stoppage Accuracy (Variation In control system is not induded) mm (IN) PI.ton sPMd mm/'sec (I.v.c) Type ot IockJng 50(2) 300(12) 100(4) 500 (20) Spring lock O.4 (C.016) iO.S (O.02) .11.0 (~O .o.I) :::2.0 {:to 08) Air pres.u ... lOCk O 2 (a.008) 0.3 (O.OI 2) O .S (i O .02) =. 1.5 (O .OS) Sori...Alr _roM." I"".
Model ZK2-ZSV-A Rated pressure range -100 to 100 kPa Set/Display pressure range -105 to 105 kPa Proof pressure 500 kPa Minimum setting unit 0.1 kPa 12 to 24 VDC 10%, Ripple (P-P) 10% or less Power supply voltage (Protected against reverse connection) Current consumption 40 mA or less NPN or PNP open collector Output type OUT1: General purpose, OUT2: Valve control Maximum load current 80 mA
Model ZK2-ZSV-A Rated pressure range -100 to 100 kPa Set/Display pressure range -105 to 105 kPa Proof pressure 500 kPa Minimum setting unit 0.1 kPa 12 to 24 VDC 10%, Ripple (P-P) 10% or less Power supply voltage (Protected against reverse connection) Current consumption 40 mA or less NPN or PNP open collector Output type OUT1: General purpose, OUT2: Valve control Maximum load current 80 mA
To use the power of the device, the total load current must be 200 mA or less. 2:Refer to 3.3.6 Wiring of contact output signal 3.3 Installation HRL Series 3-18 HRX-OM-W060 Chapter 3 Transport and Setting Up Table 3.3-4 Contact input/output communicatin /Analog output pin number PIN No.
Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
. = 16 V Example) Load voltage at OFF Leakage current: 1 mA Load impedance: 3 k Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 k = 6 V 12 Related Product RoHS For the 12 and 16 JMGP Speed Controller with One-touch Fitting Elbow Type for M3 AS121F-M3-A-X790 Metric size (Color: Light gray) Specifications Flow Rate and Sonic Conductance Inch size (Color:
=L110 L3=L410.5 L5=L111.2 Dotted line: DIN rail mounting (-D) Dimensions n: Station (Max. 20) L n 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 389 759 352 722 315 685 278 648 L1 L2 L3 L4 L5 241 611 204 574 167 537 130 500 93 463 56 426 379 749 342 712 305 675 268 638 231 601 194 564 157 527 120 490 83 453 46 416 412.5 775 375 737.5 337.5 700 300 662.5 261.5 625 225 587.5 187.5 562.5
At "L" level, Input voltage VL S 0.4V Load voltage lc Vcc 24v =5.1 mA
Poriing No. of Ports 'xx" M84010-02 Ta"NPTFSide l l M84011-02 7a" NPTF Side: Y.r" Bottom A & B 1 3 MB 4210-02 %"NPTFSid(2); % Botlom(5) 7 t 5 Manifolds *(OptionsT & P Only) Part No. Poding No.of Ports "xx" Subplates .
Response time Liie VOZ]000I0 rns -l VOZ2000 l2 ms 1 200 rfillion VoZsooo ls ms -l cYcres DIN rail mounting 3 Port Solenoid Valve Metal Seal/Rubber Seal 5 Port Solenoid Valve Metal Slsal/Rubber Seal Base Mounted Up to 063 0 . 1 7 0 3 3 0.39 0 4 5 o.3l 0 r 0 0 4 5 0.56 N C Vdlve Base Mounted N C .
Set the total current capacity to 300 mA. 300 mA is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of I/O points. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they can be configured by one. 11.
Approx. 1 k Analog output 2.4 to 20 mA 2.5% F.S. 4 to 20 mA 2.5% F.S. Output current (Rated pressure range) Linearity Note 3) 1% F .S.
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration
Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70)