Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)], Operation Manual: Operation
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)], Operation
Fix the bracket to the Pressure switch with the set screws M35 L (2 pcs) supplied. Bracket A (Model: ZS-38-A1) Bracket B (Model: ZS-38-A2) -14No.PS-OML0003-J Bracket C (Model: ZS-38-A3) : The bracket A/B/C can be mounted in 4 ways. -15No.PS-OML0003-J Mounting with panel mount adapter Fix the panel mount adapter to the Pressure switch with the set screws M38 L (2 pcs) supplied.
Inch size 1/4" 1/8" 5/32" Flow rate (l/min(ANR)) 170 100 120 150 IN OUT Effective area (mm2) 2.6 1.5 1.8 2.3 IN P1 Note) Flow rate is the value measured under a pressure of 0.5 MPa and a temperature of 20C.
End plate L 11 1 No.
min 0.525 L/min 150 L/min 2100 L/min () CO2 0.25 L/min 0.512.5 L/min 125 L/min 250 L/min N2Ar 0.210.5 L/min 1 0.526.3 L/min 152.5 L/min 2105 L/min 2 CO2 0.25.2 L/min 0.513.1 L/min 126.2 L/min 252 L/min N2Ar 010.5 L/min 1 026.3 L/min 052.5 L/min 0105 L/min 2 CO2 05.2 L/min 013.1 L/min 026.2 L/min 052 L/min / 0.01 L/min 0.1 L/min 0.1 L/min 0.1 L/min / 3 09 L / 1 L 0.1 L/Pulse 0.1 L/
Max. suction flow rate 3 types available: 100, 300 *1 , and 600 *1 L/min (ANR) *1 Branch + Port exhaust Silencer Air consumption Max. suction flow rate: 600 L/min (ANR) 91% reduction (Under SMCs measurement conditions) ZL6 Series Suction: 300 L ZL3 Suction: 600 L Reduced by the pressure switch for vacuum with energy saving function and efficient ejectors ZL6 10% reduction Suction: 100 L ZL1
min (ANR) or less (Supply pressure: 1.0 MPa) Exhaust port: 1.2 l/min (ANR) or less (at maximum set pressure) Bleed hole: 3.5 l/min (ANR) or less (Supply pressure: 1.0 MPa) Exhaust port: 0.9 l/min (ANR) or less (at maximum set pressure) Bleed hole: 9.5 l/min (ANR) or less (Supply pressure: 1.0 MPa) Exhaust port: 2 l/min (ANR) or less (at maximum set pressure) Bleed hole: 3.5 l/min (ANR) or
How to Order 01 01 3 0 VM8 Actuator type Port size Basic 00 Rc 01 1 8 Roller lever 01 1 8 NPT N01 Adjustable roller lever 13 G F01 1 8 Adjustable rod lever 14 Number of ports 3 3 port Application Movement is changeable. Roller can be mounted to inside of lever.
C4H C6H N7H C4L C6L N7L M50.8 R1/8 NPT1/8 4 mm 6 mm 1/4 5/32 inch inch 4 mm 6 mm 1/4 5/32 inch inch () PBTCB156PPSO HNBR C3604( ) POMSUS304NBRC3604 SUS304NBR 22 g 32 g 34 g 25 g 26 g 27 g 28 g 28 g 34 g 35 g 2(AWG26) 0.15 mm 1.0 mm (3 ) 3.4 -63No.PS-OMS0006CN-G M5 7 3.5 01/N01 A 01 R1/8 10 N01 NPT1/8 12 C4HC6HN7H 2.5 A B C4H 15.6 8 C6H 16.5 10 N7H 16 10.3 C4LC6LN7L
AV Regulating pressure range AU Ambient and operating temperature range Weight AF Model AR Port size Model IR IN OUT ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R 1/8, M5 x 0.8 Rc 1/8 VEX NPT 1/8, M5 x 0.8 NPT 1/8 4 One-touch fitting AMR R 1/8, M5 x 0.8 6 One-touch fitting NPT 1/8, M5 x 0.8 5/32" One-touch fitting ITV 1/4" One-touch fitting JIS Symbol
'1l8 NPT G43-P10-N01 or KSl OB-AD1 1 (St.
Ii' .. , . t ~ .230 42.2 25.8 38.9 ' 39.5 33.9 44.7 28.2 35. 1 10.5 17 ~ 35 A SP330F-N01-07S 1/4" NPT1 /8 10-32UNF ASP330F-N01 -09$ 5/16" ~ 14.2 118 15.8 15 .2 :.g 1/2' 8 NP'W~ " ~ NE?'T, lta ".,I:SP'43oFi!
Port size Instruction manual Symbol Description Flow rate range 10 With instruction manual (Leaflet: Japanese and English) None Nil N 25 50 11 01 02 N01 N02 F01 F02 C4 C6 C8 N7 Rc1/8 Rc1/4 NPT1/8 NPT1/4 G1/8 G1/4 Unit specification With unit switching function M Nil Fixed SI unit Note) Note) Fixed unit: Real-time flow rate: l/min Accumulated flow: l 4 (5/32") one-touch fitting 6 one-touch
min(ANR) Flow rate l/min(ANR) ARX21-01 ARX21-02 0.35 0.35 0.30 0.30 Downstream pressure MPa Downstream pressure MPa 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 0 0 50 100 150 200 250 300 350 400 450 500 0 0 50 100 150 200 250 300 350 400 450 500 Flow rate l/min(ANR) Flow rate l/min(ANR) Pressure characteristics Conditions: Upstream pressure 2.0MPa Downstream pressure 0.8MPa Flow rate
Vacuum Pad: Ball Joint Type ZPT/ZPR Series Pad Diameter: 10, 13, 16, 20, 25, 32, 40, 50 on n io on n a io a pt pt s s or la or la ds nt ds nt ed ed a a or or w w l f l f or or ea ea k k id su id su pe rfa pe rfa ty ty ce ce nt nt s s oi oi ac ac l j l j ac ac al al e e B B s s ZP3 ZP3E ZP2 ZP2V ZP ZPT ZPR ZPT ZPR XT661 ZPT Series: Vertical Vacuum Entry Type ZPR Series: Lateral Vacuum Entry
(Refer to Copy function on page 10.) 5 Series ZSE30A(F)/ISE30A Dimensions Z/ISE30A(F) Piping 01 N01 / 25 8 9.5 30 200.1 2 x M3 x 0.5 thread depth 4 Lead wire with connector M5 x 0.8 10 200.1 30 01: R1/8 N01: NPT1/8 1.5 Width across flats 12 C4H C6H N7H One-touch fitting 4 mm 5/32 inch straight One-touch fitting 6 mm straight One-touch fitting 1/4 inch straight 17.95 21.75 17.55 10.3 9.8 14
port Weight Body 24 g 34 g 36 g 27 g 28 g 29 g 30 g 30 g 36 g Lead wire with connector +39g Cable specifications Conductor area 0.15 mm2 (AWG26) Insulator Outside diameter 1.0 mm Color Brown, Blue, Black, White, Gray (5 core) Sheath Finished outside diameter 3.5 -77No.PS-OMU0003-D Dimensions M5 type 01/N01 type Piping specifications Port size A 01 R1/8 Width across flats 10 N01 NPT1/8 Width
(Refer to Copy function on page 41.) 36 2-Color Display High-Precision Digital Pressure Switch ZSE30A(F)/ISE30A Series Dimensions Z/ISE30A(F) Piping specifications ZSE20 ISE20 ZSE30 ISE30 ZSE30 ISE30 01 N01 / ZSE40 ISE40 25 8 9.5 1.5 30 200.1 2 x M3 x 0.5 thread depth 4 Lead wire with connector ZSE10 ISE10 ISE70 M5 x 0.8 10 ZSE80 ISE80 200.1 30 01: R1/8 N01: NPT1/8 PS ISA3 Width across flats
Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: N01 (Screw-in NPT 1/8), VAC: N01 (Screw-in NPT 1/8), EXH: N01 (Screw-in NPT 1/8)