First-stage stroke can be specified without changing the overall length. 0.02 or less repeatability in intermediate stop positioning High accuracy is achieved by an intermediate stop method of pressing metallic components against each other First-stage stroke can be freely specified.
One branch of manifold valves/input unit can be connected to 32 outputs/32 inputs. Up to 4 branches can be connected (total 128 outputs/128 inputs).
First-stage stroke can be specified without changing the overall length. 0.02 or less repeatability in intermediate stop positioning High accuracy is achieved by an intermediate stop method of pressing metallic components against each other First-stage stroke can be freely specified.
Temperature rise Mounting orientation Unrestricted Note 3) SGH 5.6 VA (50 Hz) 5.0 VA (60 Hz) 3.4 VA (50 Hz) 2.3 VA (60 Hz) 12.7 VA (50 Hz) 10.7 VA (60 Hz) 7.6 VA (50 Hz) 5.4 VA (60 Hz) Note 1) No freezing Note 2) This product cannot be used in water. Note 3) For external pilot solenoid, it is recommended that the pilot solenoid valve be oriented either vertically upward or horizontally.
When using the product in the vertical direction, if the load factor is large, the operating speed can be faster than the control speed of the speed controller (i.e. quick extension). In such cases, it is recommended to use a dual speed controller. M8 12.5 to 15.5 Allowable Kinetic Energy Caution Load mass and a maximum speed must be within the ranges shown in the graph below. 3.
These can be mounted on all filter models. Differential pressure indicator Operating pressure0.275 MPa Once a value is displayed, it will continue to be displayed until reset, even if the pump is stopped.
These can be mounted on all filter models. Differential pressure indicator Operating pressure0.13 MPa Once a value is displayed, it will continue to be displayed until reset, even if the pump is stopped.
IP8000 4 F 50140mm G (A) IP8000/IP8100 5 H IP8100 J 420mADC IP8100 JR 420mADC 6 1 1 ExdBT5 -2060 -2080 ExdBT5 2 IP8000-011-AG 3A90cm B180cm 4 5ABAB (A) 6J 26 13.
These can be mounted on all filter models. Differential pressure indicator Operating pressure0.13 MPa Once a value is displayed, it will continue to be displayed until reset, even if the pump is stopped.
If the operating pressure is too low, low speed operation may not be stable depending on the condition of the load. Furthermore, the maximum speed may be restricted depending on the pneumatic circuit or operating pressure. 2. Grease packs When maintenance requires only grease, use the following part numbers to order. Grease pack GR-L-005 (5g) GR-L-010 (10g) GR-L-150 (150g) 8
CUX32-PS M5 2.55 10% Due to cylinder structure, 10mm bore size seals cannot be replaced. M6 4.02 10% 2. Grease pack When maintenance requires only grease, use the following part numbers to order. Grease pack GR-L-005 (5g) GR-L-010 (10g) GR-L-150 (150g) Operation Warning 1. The speed may not be controllable during low speed operation with the meter-out controller. Caution 1.
.: GR-S-010 (10 g), GR-S-020 (20 g) Cylinder tube gasket NBR Cushion valve seal Piston gasket Pipe gasket Head cover gasket Disassembly/Replacement 1. Please consult with SMC when the rod seal is to be replaced. When the rod seal is to be replaced, make sure that the seal's width across flats matches that of the non-rotating guide.
.: GR-S-010 (10 g), GR-S-020 (20 g) Cylinder tube gasket 29, 32, 34 and 35 are non-replaceable parts, so they are not included in the seal kit. Cushion valve seal NBR Piston gasket Pipe gasket Speed adjustment valve seal Gasket 35 #6 Valve port gasket Disassembly/Replacement 1. Please consult with SMC when the rod seal is to be replaced.
.: GR-S-010 (10 g), GR-S-020 (20 g) Cushion valve seal NBR Cylinder tube gasket NBR Disassembly/Replacement 1. Please consult with SMC when the rod seal is to be replaced. When the rod seal is to be replaced, make sure that the seal's width across flats matches that of the non-rotating guide. A rod seal may allow air leakage depending on the position where it is installed.
.: GR-S-010 (10 g), GR-S-020 (20 g) Piston seal NBR Cushion valve seal NBR Cylinder tube gasket NBR Disassembly/Replacement 1. Please consult with SMC when the rod seal is to be replaced. When the rod seal is to be replaced, make sure that the seal's width across flats matches that of the non-rotating guide.
Water-soluble coolant Piston speed .. 200mm/sec (60cpm) Special scraper Two types of seal material NBR or FKM can be selected to accommodate the application. Can be disassembled (Series CG5-S) Replacement of seals promotes an extended service life. (Before disassembly, be sure to see the section regarding maintenance under "Specific Product Precautions" on page 32.)
Order the grease for the standard MGP series product using the part number “GR-S-010.”
Be sure to check the part number of the MGP-Z series product before ordering the seal kit. The old MGP series was discontinued in April 2012. Old and new seal kits are not interchangeable (and the seal kit part numbers will also differ).
.: GR-S-010 (10 g), GR-S-020 (20 g) Cylinder tube gasket 29, 32, 34 and 35 are non-replaceable parts, so they are not included in the seal kit. Cushion valve seal NBR Piston gasket Pipe gasket Speed adjustment valve seal Gasket 35 #6 Valve port gasket Disassembly/Replacement 1. Please consult with SMC when the rod seal is to be replaced.
DZ: For DIN terminal with light/surge suppressor protection circuit, be sure to add suffix -X200 at the end of the part number.
.: GR-S-010 (10 g) Disassembly/Replacement Caution 1. Do not replace the bushings. The bushings are press-fit. To replace them, they must be replaced together with the cover assembly. 2. To replace a seal, apply grease to the new seal before installing it.