SMC Corporation of America
Elite Part Number Search
Search Results "HRS090-AN-46-M"

Lead wire length symbols: 0.5 m Nil (Example) Y69A 3 m L (Example) Y69AL 5 m Z (Example) Y69AZ Since there are applicable auto switches other than the listed above, refer to page 9-11-29.

Bore size 20, 25/MLGPM20/25 (Slide bearing) Operating Range as Stopper for MLGPM20/25 100 25 l = 50 mm l = 50 mm Weight of transferred object: m (kg) m m 20 5 10 10 20 30 40 50 Transfer speed: (m/min) Bore size 32 to 100/MLGPM32 to 100 (Slide bearing) Operating Range as Stopper for MLGPM32 to 100 1000 Weight of transferred object: m (kg) l = 50 mm l = 50 mm 100 m m 80 63 50 40 32 100

Calculating Acceleration/deceleration conversion example using an actuator with a 8 [mm] lead with an acceleration of 3000[mm/sec2].

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Method: Air-cooled Refrigeration, Pipe Thread: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: -

Cooling Method: Water-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: -

Cooling Method: Air-cooled Refrigeration, Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: -

Cooling Method: Water-cooled Refrigeration, Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: -

plug connector (M) M8 connector (WO) Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 58.7 [60.9] 48.9 [51.1] 57.8 50.4 43.9 Refer to page 646 for dimensions with connector cable.

JS20, 32, 40, 63 Center of sphere M M U U D J F B E G P A R H (mm) Max. thread depth P Center of sphere R Allowable eccentricity U Max. operating tension and compression force (N) Weight (kg) M A B C D E F G H J Model JS10-4-070 JS16-5-080 8.5 0.5 17 0.01 14.4 M4 x 0.7 9.5 12 4 7 4.7 80 4 1.5 26 12 0.5 23 19 0.02 M5 x 0.8 13.5 16 6 10 5.8 210 5 2 34.5 JS20-8-125 JS32-10-125 15.5 0.5 29.9

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state switches marked with are produced upon receipt of order. Since there are other applicable auto switches than listed above, refer to the Best Pneumatics No. 2 for details.

52 46 55 63 69 S 33 36 40 46 50 52 Z 46 52 56 65 73 79 6 10 16 20 25 32 7 9 12 16 20 24 6 depth 4.8 6 depth 5 7.6 depth 6.5 9.3 depth 8 9.3 depth 9 11 depth 11.5 5 7 Free Mount Cylinder Double Acting, Single Rod Series CU Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height D-A9 D-M9 D-F9W 22 (24.5) ( ): Denotes the values of D-A93.

(The switch will stay ON all the time.) 1) For an auto switch without a connect protection circuit, use a contact protection box when the wire length is 5 m or longer. 2) Even if an auto switch has a built-in contact protection circuit, when the wiring is more than 30 m long, it is not able to adequately absorb the rush current and its life may be reduced.

Symbol Specifications -X12 Lubricant: Vaseline -X21 Grease-free (Seal: Fluorine-coated) + Restrictor (Without check valve) -X214 Restrictor (Without check valve) 10Clean Series 565 A AS Series Needle Valve/Flow Rate Characteristics AS2201F-G02-m, AS2211F-G02-m AS2301F-G02-m, AS2311F-G02-m AS2201F-02-mPA, AS2211F-02-mPA AS2201F-G01-m, AS2211F-G01-m AS2301F-G01-m, AS2311F-G01-m AS2201F-01-mPA