The resulting impact cannot be absorbed easily, the stroke position cannot be maintained, and faulty operation may result. t Lubrication The bearing can be used in an oilless state, but when you are going to oil the bearings, do so by using a ball-cup so that no foreign matter will be mixed.
AR45 AR65 AR85 AR95 Description Model VBA Bracket Pressure gauge with limit indicator (1) B24P B25P G46-10-02 (Max. 1.0 MPa), G46-2-02 (Max. 0.2 MPa) VE Note 1) In the gauge part no. (e.g. G46-10-02), indicate kind of the connecting thread. Put nothing for Rc and N for NPT thread. Please consult with SMC for NPT pressure gauge.
integrated with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Main Board HRS018
Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS018-A-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS018-W-20-MT, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
, 3.2 kW, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018
capacities: 1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018
, 3.2 kW, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018
capacities: 1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018
When making drain exhaust piping, use piping with bore size 10 or larger than 10. Length should be shorter than 5m.
)) 00 10 11 None Float type auto-drain (N.C.)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)
Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: None
OUTPUT PRESS. 0.01 0.01 0.01 0.01 0.2MPa 0.2MPa 0.2MPa 0.2MPa IR3000 IR3000 IR3000 IR3000-02 02 02 02BG BG BG BG *** *** *** ***-*** *** *** *** Product code *** *** *** ***-*** *** *** *** Product number Max. supply pressure Set pressure range G G G G T T T To o o o MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN o Production lot no. Production lot no.
OUTPUT PRESS. 0.01 0.01 0.01 0.01 0.8MPa 0.8MPa 0.8MPa 0.8MPa Max. supply pressure Set pressure range Input pressure G G G G T T T To o o o MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN o Production lot no. Production lot no. Year Month T : 2015 o: January U : 2016 P: February V : 2017 Q: March W: 2018 R: April X : 2019 Z: December -7- 5.
OUTPUT PRESS. 0.01 0.01 0.01 0.01 0.8MPa 0.8MPa 0.8MPa 0.8MPa Max. supply pressure Set pressure range Input pressure G G G G T T T To o o o o MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN Production lot no. Production lot no. Year Month T : 2015 o: January U : 2016 P: February V : 2017 Q: March W : 2018 R: April X : 2019 Z: December -7- 5.
Mountingposition:AF+T+AR+AL + 3-portvalvefor residualpressure release f Withoutattachment Mountingposition:AF+AR+AL+V Nil V + Nil 1 g 0.05to0.7MPasetting 0.02to0.2MPasetting Set pressureNote7) + y Nil C Bowl h Polycarbonatebowl Withbowlguard 1 Air Combination Series AC20-A to AC40-A AC AFARAL AWAL AFAR AFAFMAR AWAFM AF AFM / AFD AR AL AW Attachment AC40-A AC20-A q 20 25 30 40 Body size Description
P.5-10 It indicates the set temperature. (10) Circulating fluid set temperature P.5-10 CH2 Press the numeric section to change the set temperature. (11) Circulating fluid discharge pressure It indicates the discharge pressure.
MY1HT series is held by T slot at the bottom. Fig. 2: Holding the product from the top Fig. 3: Holding the product from the bottom (Head cover at both ends) (Head cover, T slot only for MY1HT) At least 5mm of both ends of the cylinder tube have to contact with the attachment point.
OUTPUT PRESS. 0.005 0.005 0.005 0.005 0.2MPa 0.2MPa 0.2MPa 0.2MPa IR2000 IR2000 IR2000 IR2000-02 02 02 02BG BG BG BG *** *** *** ***-*** *** *** *** Product code *** *** *** ***-*** *** *** *** Product number Max. supply pressure Set pressure range T T T To o o o G G G G MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN o Production lot no. Production lot no.