(Element life check) Max. contact capacity: 10 VA AC, 10 W DC Rated contact voltage (max. operating current): 125 V AC (0.08 A), 30 V DC (0.33 A) Max. contact capacity: 10 W DC Rated contact voltage (max. operating current): 30 V DC (0.33 A) Pressure drop 0.1 MPa Symbol V: Degreasing wash, white vaseline Reed switch Reed switch Body/housing is degreasing washed.
Series 10-/11-/12-/13Clean Series Available for clean environment. Particle generation in a clean room can be prevented.
Series 10-/11-/12-/13Clean Series Available for clean environment. Particle generation in a clean room can be prevented.
23.5 28 ( ): Single acting, spring return 16 Series CUJ Auto Switch: Proper Mounting Position (Detection at Stroke End) D-F8 D-M9/M9W When detecting extended stroke end When detecting retracted stroke end 10 mm or more 10 mm or more Note 2) A B A B Stroke A + Stroke B D-F8 D-M9/M9W Bore size (mm) Double acting Single acting A B Single acting Double acting A B A B A B 6 8 10 12 16 20 1
is required. 7.5 40 Work load [kg] Work load [kg] 30 5 LEJS40;A LEJS40;A 20 AC Servo Motor Specific Product 2.5 10 0 0 0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200 Speed [mm/s] Speed [mm/s] LEJS63/Ball Screw Drive Horizontal Vertical 90 20 LEJS63;B LEJS63;B 80 70 Precautions LECS; 15 60 Work load [kg] Work load [kg] 50 10 40 LEJS63;A LEJS63;A 30 5 20 10 0 0 0 1200 200 400 600
Series 10-/11-/12-/13Clean Series Available for clean environment. Particle generation in a clean room can be prevented.
Series 10-/11-/12-/13Clean Series Available for clean environment. Particle generation in a clean room can be prevented.
Basic (Through-hole/Both ends tapped common): CQUB F Q 2 x M5 x 0.8 Y 4 x M6 x 1 depth 10 4 x 5.4 through 15 KA H H1 Rod end nut Width across flats B1 NY EY D X C1 K NX A + Stroke B + Stroke L EX L1 Rod end male thread Basic (mm) Size Stroke range (mm) A B D EX EY F H K KA L NX NY Q Y 20 25 32 40 5 to 50 49 42.5 10 22 47 11.5 M5 x 0.8 depth 8 5 8 6.5 5.5 36 15 3 5 to 50 49 42.5 10 24 53 11
Series 10-/11-/12-/13Clean Series Available for clean environment. Particle generation in a clean room can be prevented.
Cable colour Terminal No. 8 8m* Vcc B-1 Brown 12 GND A-1 Black 13 A 10m* A B-2 Red 7 A A-2 Black 6 B 15m* B B-3 Orange 9 C 20m* B A-3 Black 8 SD+(RX) B-4 Yellow 11 * Produced upon receipt SD-(TX) A-4 Black 10 of order Black 3 Actuator side Controller side (14.2) (c) (b) (10.2) (5.5 (6.7 (12.7) 6 2 1 (a) (14 (18) A B 5 6 (13.5) 1 3 1 4 2 1 (30.7) (14.7) 15 16 (d) L (10) (11) 10 - [2] Actuator
20. 9-1 9.1.2 HRLE090-A-20. 9-2 9.1.3 HRLE050-W-20. 9-3 9.1.4 HRLE090-W-20. 9-4 9.1.5 HRLE090-A-40. 9-5 9.1.6 HRLE090-W-40. 9-6 9.2 REFRIGERANT AND GWP VALUE . 9-7 9.3 DIMENSIONS . 9-8 9.3.1 HRLE050-A-20. 9-8 9.3.2 HRLE050-W-20. 9-9 9.3.3 HRLE090-A-20/40. 9-10 9.3.4 HRLE090-W-20/40. 9-11 9.4 FLOW DIAGRAM . 9-12 9.4.1 HRLE050-A-20-*,HRLE090-A-20/40. 9-12 9.4.2 HRLE050-W-20-*,HRLE090-W-20/40
Cable colour Terminal No. 8 8m* Vcc B-1 Brown 12 GND A-1 Black 13 A 10m* A B-2 Red 7 A A-2 Black 6 B 15m* B B-3 Orange 9 C 20m* B A-3 Black 8 SD+(RX) B-4 Yellow 11 * Produced upon receipt SD-(TX) A-4 Black 10 of order Black 3 Actuator side Controller side (14.2) (c) (b) (10.2) (5.5 (6.7 (12.7) 6 2 1 (a) (14 (18) A B 5 6 (13.5) 1 3 1 4 2 1 (30.7) (14.7) 15 16 (d) L (10) (11) 10 - [2] Actuator
A magnetic type origin detection sensor is used for controlling the automatic cleaning. Keep magnetic field more than 50 mT away from the ionizer enclosure. If a magnetic field more than 50 mT approaches the ionizer enclosure, the ionizer may malfunction.
Cooling Capacity: 018 [Cooling Capacity: 1700/1900 W (50/60 Hz)], Pipe Thread: Rc, Option: V (Stainless Steel Panel Specification)
Cooling Capacity: 018 [Cooling Capacity: 1700/1900 W (50/60 Hz)], Pipe Thread: Rc, Option: T (High-pressure Pump Mounted)
A large digital display provides a clear view of the current and set values.
Cooling Capacity: 018 [Cooling Capacity: 1700/1900 W (50/60 Hz)], Pipe Thread: Rc, Option: Stainless Steel Panel Specification
Cooling Capacity: 018 [Cooling Capacity: 1700/1900 W (50/60 Hz)], Pipe Thread: Rc, Option: High-pressure Pump Mounted
A large digital display provides a clear view of the current and set values.
A large digital display provides a clear view of the current and set values.