Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: w/Electric Conductivity Control Function, Applicable to DI Water Piping, High Pressure Pump: High Pressure Inverter Pump Mounted, Feet: -, Flow Sensor: -
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T2 (High Pressure Inverter Pump Mounted), Feet: Y (with Feet/Without Rack Mounting Brackets)
Rack Mount Refrigeration Chiller. O72. 74.00000 lb. CHILLER, RACK MOUNT, REFRIGERATION TYPE.
Rack Mount Refrigeration Chiller. O72. 74.00000 lb. CHILLER, RACK MOUNT, REFRIGERATION TYPE.
Rack Mount Refrigeration Chiller. O72. 74.00000 lb. CHILLER, RACK MOUNT, REFRIGERATION TYPE.
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T2 (High Pressure Inverter Pump Mounted), Feet: None, Flow Sensor: Z1 (without Either a Flow Sensor or Retaining Clip)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T1 (Inverter Pump Mounted), Feet: Y (with Feet/Without Rack Mounting Brackets), Flow Sensor: Z1 (without Either a Flow Sensor or Retaining Clip)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T2 (High Pressure Inverter Pump Mounted), Feet: Y (with Feet/Without Rack Mounting Brackets), Flow Sensor: Z1 (without Either a Flow Sensor or Retaining Clip)
Cooling Capacity: 200 (20.5kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AKM (A + K + M)
Cooling Capacity: 400 (CH1: 37 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: T2 (20 L/min, CH2 Optical Head)
Cooling Capacity: 200 (CH1: 19 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: T2 (20 L/min, CH2 Optical Head)
Cooling Capacity: CH1: 26 kW; CH2: 1 kW, Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)], DI Option: -, Pump Option: -
Cooling Capacity: CH1: 26 kW; CH2: 1 kW, Pipe Thread: F [G (Rc-G Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)], DI Option: -, Pump Option: -
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)]
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: F [G (Rc-G Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)]
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Dual Channel Chiller for Lasers, CHILLER, 729, 315 lb
Valve Type: 23 (3-port, N.C. on one side, N.O. on none side), Voltage: 5 (24VDC), Electrical Entry: K (Plug Connector, 300mm), Light: Z (with Light), Tubing Size: 3 (OD x ID: ø3 x ø1; Length: 100mm)
Valve Type: 21 (N.C.), Voltage: 6 (12VDC), Electrical Entry: K (Plug Connector, 300mm), Light: Z (with Light), Tubing Size: 3 (OD x ID: ø3 x ø1; Length: 100mm)
Type: Base for Manifolds, Communication Protocol: -, Output Format: -, Type: Input Manifold, Number of Inputs/Outputs: -, Connector: M12 Connector, Number of Stations: 3, Rated Voltage: -, Specification: -