When system performance declines due to filter element clogging, worn vacuum pads, piping leakage, etc., the switch can detect and indicate an oncoming problem before failure occurs.
Therefore, do not operate it in an environment that is exposed to chemicals such as thinner, carbon tetrachloride, chloroform, acetic ester, aniline, cyclohexane, trichloroethylene, sulfuric acid, lactic acid, or water-soluble cutting oil (alkalinic). 2. Operate it away from direct sunlight.
Do not use in locations having an explosive atmosphere. 2. Do not operate in locations where vibration or impact occurs. 3. In locations near heat sources, block off radiation heat. 4. Do not use in environments which exceed the ambient temperature specifications of the product. Caution 1.
50 15, 20, 25, 30, 40, 50 20, 25, 30, 40, 50, 75, 100 30, 40, 50, 75, 100 Manufacture of Intermediate Strokes Special body type Refer to ordering procedure for standard part numbers.
K ( across flats) H (With locking) 80 9 6.5 10 18 50 YB-03 32, 40 120 11 6.5 12 22 60 YB-05 50, 63 d2 d1 L UT C UA (mm) UA C d1 d2 H k L UT Weight (g) 25 Part No.
(D1) TUH/Standard type 4 2.8 6 4.4 8 5.8 10 7.3 12 8.8 I.D. (D2) O.D. (D1) Tubing I.D. (D2) TUH/High pressure type TU 8 2.5 4 5 6.5 1in = 25.4mm Operating pressure 1.0MPa (at 20C) [145 psi @ 68F] TUH/High Pressure Type Same operating pressure as series TS soft nylon tubing, and a bending radius equivalent to series TU polyurethane tubing.
Flame Resistant One-touch Fittings Series KR Cover Collet Guide Prevention of tube releasing unconformity due to an inside intrusion or adhesion of the spatter. Chuck Release button (Green) Accepts FR soft nylon. Has high retaining force. Chuck certainly bites tube and collet increases retaining force. Low disconnecting force.
Light weight Together with a reduction of the body size, pressing parts and resin parts are used to achieve an overall weight reduction. Body O.D. Pressing parts Resin parts Body O.D. mm 18.2 25.4 31.2 Weight g Note 2) Series Series KK3 Series KK4 Series KK6 Socket no. KK3S-01MS KK4S-02MS KK6S-04MS Plug no.
Channel Refrigerated Thermo-chiller for Lasers HRL Series How to Order HRL A 20 100 Power supply Cooling capacity CH1 CH2 100 9 kW 1 kW 200 19 kW 1 kW 300 26 kW 1 kW 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) Pipe thread type Nil Rc F G (with Rc-G conversion tting) N NPT (with Rc-NPT conversion tting) Cooling method A Air-cooled refrigeration Specications Model HRL100-Am-20 HRL200
(D1) TUH/Standard type 4 2.8 6 4.4 8 5.8 10 7.3 12 8.8 I.D. (D2) O.D. (D1) Tubing I.D. (D2) TUH/High pressure type TU 8 2.5 4 5 6.5 1in = 25.4mm Operating pressure 1.0MPa (at 20C) [145 psi @ 68F] TUH/High Pressure Type Same operating pressure as series TS soft nylon tubing, and a bending radius equivalent to series TU polyurethane tubing.
Joints 12 7 25 9 34 11.5, depth 7.5 YB-03 32, 40 K ( across flats) 12 9 32 11 42 14.5, depth 8.5 YB-05 50, 63 H (with locking) 16 11 38 13 52 18, depth 12 YB-08 80 d2 d1 19 14 50 17 62 21, depth 14 YB-10 100 L UT Weight (g) Bore size (mm) C UA RS W T1 T2 V Part no. (mm) 9 50 18 6.5 10 YB-03 32, 40 80 UA C d1 d2 H K L UT Weight (g) Part no.
(inch) Connection thread UNF NPT
Max. operating pressure Note 1) 2R (MPa) One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings Applicable fittings Note 1) Note 2) Min. bending radius 100 15 25 30 50 65 13 20 24 30 40 50 60 Min. bending radius (mm) Note 3) Fixed end Bending value (Reference) 75 12 20 23 40 48 10 15 18 23 30 40 45 40 to +100C, Water: 0 to +70C (No freezing) Nylon 12 Operating temperature
Note 1) This cylinder cannot perform an intermediate stop using an air pressure circuit in vertical operation. In this case, an intermediate stop can be performed only by using an external stopper, etc. Note 2) Made-to-order products should be considered, too, depending on an operating environment, etc.
32 CY1S40L 0.40 CY1S32L 18.2 0.40 CY1S CY1S40H 47.0 0.65 40 CY1S40L 29.0 0.40 CY1L 2) Intermediate stopping of load with an air pressure circuit When stopping a load using an air pressure circuit, operate at or below the kinetic energy shown in the table below.
AC DC 60 40 1 99 60 120 183 Application Example Maximum 40 N.C. (VX31) N.O. (VX31) C.O.
The cushion effect (smooth start-up, soft stop) cannot be obtained in an intermediate stop or a return from an intermediate stop using an external stopper, etc.
(Including bracket, screw) 20Applicable bore size (mm) 40 Applicable bore size (mm) 40 BMG1-040 50 BMG1-040 63 BMG1-040 80 BMG1-040 100 BMG1-040 Data Cylinder series Cylinder series 50 63 80 BQP1-050 100 BQP1-050 CDQ2 MK, MK2 MGP, MLGP BQP1-050 BQP1-050 BQP1-050 Caution Auto Switch Mounting Tool When tightening hexagon socket head cap screw of an auto switch, use a hexagon wrench key 2
Bore sizes 10, 20, 30, 40, 50 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75, 100 Standard strokes (mm) 6 10, 15 20, 25, 32 Applicable auto switches: Refer to pages 40 through 49 for detailed auto switch specifications.
Spring return Spring extend C C D 35 40 40 45 40 45 40 45 40 45 45 50 55 60 D 40 45 40 45 40 45 40 45 40 45 45 50 55 65 Mounting bolt M3 X 35 l X 40 l M3 X 40 l X 45 l M5 X 40 l X 45 l M5 X 40 l X 45 l M5 X 40 l X 45 l M5 X 45 l X 50 l M6 X 55 l X 60 l Mounting bolt M3 X 40 l X 45 l M3 X 40 l X 45 l M5 X 40 l X 45 l M5 X 40 l X 45 l M5 X 40 l X 45 l M5 X 45 l X 50 l M6 X 55 l X 65 l Model