This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, ME, 40MM CY1H/CY1L DBL-ACT A/S, 23.85891 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)40CY1L40H47.00.65
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, ME, 40MM CY1H/CY1L DBL-ACT A/S, 28.99078 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)40CY1L40H47.00.65
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, ME, 40MM CY1H/CY1L DBL-ACT A/S, 25.35316 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)40CY1L40H47.00.65
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, ME, 40MM CY1H/CY1L DBL-ACT A/S, 21.75228 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)40CY1L40H47.00.65
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, ME, 40MM CY1H/CY1L DBL-ACT A/S, 24.06712 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)40CY1L40H47.00.65
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, ME, 40MM CY1H/CY1L DBL-ACT A/S, 28.17644 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)40CY1L40H47.00.65
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, ME, 40MM CY1H/CY1L DBL-ACT A/S, 24.69177 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)40CY1L40H47.00.65
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, ME, 40MM CY1H/CY1L DBL-ACT A/S, 22.48715 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)40CY1L40H47.00.65
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
Lead wire length (m) Load voltage Rail mounting Indicator light Wiring (Output) Special function Type Electrical entry Pre-wired connector Applicable load 0.5 (Nil) 3 (L) 5 (Z) None (N) AC Perpendicular In-line DC IC circuit 3-wire (NPN equivalent) A76H 5 V Reed switch Solid state switch Grommet A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F A72 A73 A73C A79W F7NV F7PV F7B J79C F7NWV
Applicable models: D-A73/A73H/A73C D-A93/A93V 2) Note however, that in the case of 2 color indication auto switches (D-A79W), the switch will be in a normally ON condition if the wiring is reversed.
Applicable models: D-A93, A93V, D-A73, D-A73H, D-A73C
CRBU CRA1 Model: MRQBS32-50CA-A73 Operating pressure: 0.5MPa Calculate the amount of air requirement for A, B, C and D respectively.
Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.
) 3-wire (PNP) 5V, 12V Grommet 2-wire 12V Connector 10 15 3-wire (NPN) 3-wire (PNP) 24V IC circuit Diagnostic indication (2-color indication) 5V, 12V Yes Yes Yes Yes No No No 15 Relay, PLC 25 25 Grommet 12V 2-wire Water resistant (2-color indication) F7BA F7BAV With diagnostic output (2-color indication) IC circuit F79F 4-wire (NPN) 5V, 12V A76H A72H A73H A80H E76A E73A E80A A72 A73
Applicable model: D-A73, A73H, A73C, C73, C73C, E73A, Z73 D-R73, R73C, 97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed.
Auto switch type Model Features Electrical entry (Fetching direction) D-A73 If the cylinder is used in an application in which a magnetic material is placed in close contact around the cylinder as shown in the graph on the below (including cases in which even one of the sides is in close contact) the operation of auto switches could become unstable.