SMC Corporation of America
Elite Part Number Search
Search Results "CXSJM6-50-M9BA"

0 10 20 30 40 50 F1 Gripping point L (mm) Gripping point L (mm) F1 F1 532 MHR3/MDHR3 Series Rotary Actuated Air Gripper 3-Finger Type Construction q !

CQ2 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 Built-in Magnet Cylinder Model Double acting Action D 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 RQ If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the auto switch. (Example) CDQSL25-30D 25 For Manufacture of Intermediate Strokes, refer to page 552.

Bore size 20 25 32 40 50 63 20 mm (3/4) 25 mm (1) 32 mm (1-1/4) 40 mm (1-1/2) 50 mm (2) 63 mm (2-1/2) Cylinder stroke (inch) How to Order Without auto switch 40 L 25 N CG1 L N 25 M9NW 40 CDG1 With auto switch Number of auto switches Built-in magnet Mounting style Nil S n 2 pcs. 1 pc. n pcs.

Bore size 12 16 20 25 32 12 to 25 M thread Rc NPT G Nil 40 50 63 80 100 12 mm 16 mm 20 mm 25 mm 32 mm 40 mm 50 mm 63 mm 80 mm 100 mm Built-in Magnet Cylinder Model TN TF 32 to 100 If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the auto switch.

Output operation of the solid state auto switch is not stable for 50 [ms] after powered ON. In the output operation immediately after powered ON or AND connection operation, the input device (PCL or relay, etc.) may judge the ON position as OFF output or the OFF position as ON output.

Output operation of the solid state auto switch is not stable for 50 [ms] after powered ON. In the output operation immediately after powered ON or AND connection operation, the input device (PCL or relay, etc.) may judge the ON position as OFF output or the OFF position as ON output.

Guide Table Bore size/ Standard stroke (mm) Number of auto switches 40 63 100 30, 50, 75, 100 30, 50, 75, 100 30, 50, 75, 100 2 pcs. 1 pc. "n" pcs. Nil S n Auto switch Nil Without auto switch (Built-in magnet) Select applicable auto switches from the table below. Applicable Auto Switch/Refer to pages 1719 to 1827 for further information on auto switches.

Bore size 32 40 50 63 32 mm 40 mm 50 mm 63 mm Auto switch Nil Without auto switch (Built-in magnet) For the applicable auto switch model, refer to the table below. Port thread type Type Rc NPT G Symbol Nil TN TF Double acting Action D Applicable Auto Switch/Refer to pages 761 to 809 for further information on auto switches.

/60 Hz 200 VAC 50/60 Hz 110 VAC [115 VAC] 50/60 Hz 220 VAC [230 VAC] 550/60 Hz 24 VDC 12 VDC Note) Refer to the back of page 394 when using with energization for long periods of time.

Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 6 to Less than 10 / 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 80,

Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves

Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves

Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves: Provided

Oscillation Angle A: 190°, Torque (Range)(N⋅m): 6 to Less than 10 / 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 80, Valves

Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves

Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves

Example Calculation:25, B dimension 27.5 mm (without auto switch) 27.5 (B dimension) + 50 (st) = 77.5 (mm) D-X 1169

Size Rod end thread 20 25 32 40 Piston area equivalent to 20 mm Piston area equivalent to 25 mm Piston area equivalent to 32 mm Piston area equivalent to 40 mm Rod end female thread Rod end male thread Nil M Cylinder stroke (mm) Size Stroke 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 20, 25 32, 40 Applicable Auto Switches/Refer to pages 13 through

Thread type Opening/Closing stroke (mm) Cylinder bore Symbol Type 10 20 40 60 16 30 60 80 20 40 80 100 25 50 100 120 32 70 120 160 40 100 160 200 Symbol Nil 10 to 25 M thread Rc NPT G Nil 1 2 TN TF 32 to 40 Double acting Action D Applicable Auto Switch/Refer to pages 761 to 809 for further information on the auto switches.