SMC Corporation of America
Elite Part Number Search
Search Results "CV3FN40-125-5-B"

5 5 5.5 5.5 5 5 5 5.5 5.5 D-M9 type cannot be mounted on 25 and 40.

-10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B25-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B80-10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 C(D)55B40-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B50-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B63-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100

FY MGQ MGG FT FZ FX MGC (mm) MGF Stroke range Bore size (mm) B FT FD FX FY FZ MGZ 40 50 63 74 78 100 9 9 12 12 16 16 80 100 112 58 61 75 100 125 138 Up to 1000 Up to 1000 Up to 1000 MGT Head flange style: (G) 4 x FD B FY ZZ + Stroke FT FX FZ D(mm) -X Stroke range Bore size (mm) B FT FD FX FY FZ ZZ Individual -X 40 50 63 74 78 100 9 9 12 12 16 16 80 100 112 58 61 75 100 125 138 220 244 270

D-P7l type 5 32 A B Hs Note) The above drawing is the switch rod mounting example for the D-P79WSE type.

No. of tubes Color Black (B) Black (B) Black (B) Black (B) Black (B) Black (B) Black (B) Max. operating length m Model O.D. TCU0425B-1 TCU0425B-2 TCU0425B-3 TCU0604B-1 TCU0604B-2 TCU0604B-3 TCU0805B-1 1 1.5 4 2.5 2 1 3 2 1 6 4 1.5 2 1 3 8 5 2 1 Best Pneumatics Best Pneumatics Refer to page 2.5-3 of No. 4 for details.

Z + Stroke S + Stroke WW C B 0 0.3 B 0 0.3 Drawing of view (E) (mm) 28 28 NA 102.5 101.5 45 45 20 20 NB LB 21.5 23 Bore size A M4 x 0.7 D GC B F H NN Z WW WA WB X 6 6 MM GB GA C S LC 5.5 5.5 Y 9 9 LH 14 14 LT 2.3 2.3 LX 33 33 LY 25 25 LZ 42 42 15 15 16 10 18.3 15 20 17 8 8 5 5 6.5 6.5 11 11 29.5 29.5 4 5 74.5 73.5 M10 x 1.0 22.9 22.9 13.4 13.4 M5 x 0.8 M12 x 1.0 5 B Air Cylinder CJ2 10-/1121

5 300 200 LEY32 Motor mounting position: Top/Parallel 200 W /60 (Motor rotation speed) (3600 rpm) (2400 rpm) A 16 1000 640 B 8 500 320 C 4 250 160 LEY32D Motor mounting position: In-line 200 W /60 (Motor rotation speed) (3750 rpm) (2400 rpm) A 20 1000 800 600 500 B 10 500 400 300 250 C 5 250 200 150 125 LEY63 Motor mounting position: Top/Parallel, In-line 400 W /60 (Motor rotation speed

C 15 18.3 B 90 91 GC 17 20 NB 20.5 20.5 NA M10 x 1.0 M12 x 1.0 S 9.5 9.5 Z 54 55 NN M4 x 0.7 M5 x 0.8 A 10 16 D 15 15 F 4 5 GA 8 8 GB 5 5 H 5 5 MM 28 28 Bore size 11 11 10-0.022 0 12-0.027 0 With air cushion Air cushion type is not available for 21-/22-CJ2.

175 200 250 300 350 400 NCQ8B200-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B250-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 #4-40UNC3/4 7/8 1 1-1/8 1-1/4 1-3/8 1-1/2 1-5/8 1-7/8 2-1/8 2-3/8 2-5/8 3-1/8 3-5/8 4-1/8 4-5/8 #6-32UNC3/4 7/8 1 1-1/8 1-1/4 1-3/8 1-1/2 1-5/8 1-7/8 2-1/8 2-3/8 2-5/8 3-1/8 3-5/8 4-1/8 4-5/8 #6-32UNC1-1/8 1-1/4 1-3/8 1-

6 50 to 100 80, 100: Over 200 stroke Extension locking (Type F) Retraction locking (Type B) !9 @7 #9 #5 i o @5 #5 #9 @7 !9 i @5 o Section B-B' Section B-B' @5 !8@6!7 @5@6!7 !

6 50 to 100 80, 100: Over 200 stroke Extension locking (Type F) Retraction locking (Type B) !9 @7 #9 #5 i o @5 #5 #9 @7 !9 i @5 o Section B-B' Section B-B' @5 !8@6!7 @5@6!7 !

5 @4!8 @0!7 !9i @2 q r @8#9 $0 $2 w $3 #8 @9 A C B !3 !4 #4 $1 e$8 o $7 !1@1 !6 @5 u !0 $6#6#5 $4 y#8 @6 #3 Section B Section C Section A !2 !2 #1 #0 !2 32 100 80 63 50 40 80, 100 80, 100 Parts list Parts list No. No.

Fittings & Tubing Air Cylinders Rotary Actuators Clean series 10 11 Relief type Vacuum suction type 10 C D B M 2 B 20 100 H N M9BW C 21 C D B M 2 B 20 100 H N M9BW C Nil Built-in magnet Number of auto switches Cylinder stroke (mm) No Nil S n 2 pcs. 1 pc. "n" pcs.

Fail Action Fail to Close, Fail to Open 5 Valve Travel 85.2 % 5 Positioner Information 5 Dead Angle (a0) 0.0 % [0..99%] 6 Temperature 24.7 C 6 Units 6 Performance Level A(1)-Aggressive, b(1)-fast, C(1)-Optimum, d(1)-Stable, E-Max. stability, (1) = Capac.

Double Double Double Double Double Double Double Single Single Single Single Single Single Single Single Single Single SI unit SI unit A B A B A B A B A B A B A B A B A B A B A A A A B A A B A 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 7 8 4 5 9 11 6 10 11 Mixed wiring is available as an option. Use the manifold specification sheet to specify this.

Flow Characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) Flow characteristics Port size Model 4, 2 (A, B) Cv C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b 1, 5, 3 (P, EA, EB) SS5X3-45l SS5X5-45l C6 C8 0.88 2.2 0.21 0.24 0.22 0.53 0.95 2.5 0.18 0.18 0.22 0.58 C8 C10 Note) The value is for manifold base with 5 stations and individually operated 2 position type.

80 100 Operating range Operating range l (mm) 5 5 6 6 6 6 6 6.5 Note) This is a standard including hysteresis, and is not guaranteed.

80 100 Operating range Operating range l (mm) 5 5 6 6 6 6 6 6.5 Note) This is a standard including hysteresis, and is not guaranteed.

Tightening torque for terminal: 0.6 Nm Series VFS4000/5000 Model Terminal block marking A + A side A side A A side A side B + B VFS 100 VFS 200 VFS4 00 VFS5 00 4 5 4 5 B side B side 3 4 3 4 A side A side B side B side Applicable terminal: 1.25-3.5M, 1.25Y-3L, 1.25Y-3M There is no polarity.