SMC Corporation of America
Elite Part Number Search
Search Results "CKQGDA50-175DALSZ-P4DWSC"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, PIN CLAMP, SW CAPABLE, ACTUATOR, CKQ/CLKQ PIN CLAMP CYLINDER, NE, 50MM CKQ, CLKQ DBL ACT, SW CAP, 4.27696 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, PIN CLAMP, SW CAPABLE, ACTUATOR, CKQ/CLKQ PIN CLAMP CYLINDER, NE, 50MM CKQ, CLKQ DBL ACT, SW CAP, 4.18878 lb

SMC's CLK2 series is a perfect choice for holding applications in either a clamped or unclamped state.  CLK2 cylinders have a compact lock mechanism which minimizes the extension of the length dimension (2mm shorter), while maintaining the mounting interchangeability with the CLK1 existing product line.  The CLK2 is capable of being locked at any position within the entire stroke.  A dedicated

SMC's CLK2 series is a perfect choice for holding applications in either a clamped or unclamped state.  CLK2 cylinders have a compact lock mechanism which minimizes the extension of the length dimension (2mm shorter), while maintaining the mounting interchangeability with the CLK1 existing product line.  The CLK2 is capable of being locked at any position within the entire stroke.  A dedicated

Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P4DWSC, Lead Wire Length(m): 0.3, The number of the switches: 2 pcs., Specification: Built-in standard magnet type, Mounting surface position: Same direction as port, Piston rod tip hole diameter: ø10

Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P4DWSC, Lead Wire Length(m): 0.3, The number of the switches: 2 pcs., Specification: Built-in standard magnet type, Mounting surface position: 90° from port, Piston rod tip hole diameter: ø10

Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P4DWSC, Lead Wire Length(m): 0.3, The number of the switches: 2 pcs., Specification: Built-in standard magnet type, Mounting surface position: 180° from port, Piston rod tip hole diameter: ø10

Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P4DWSC, Lead Wire Length(m): 0.3, The number of the switches: 2 pcs., Specification: Built-in standard magnet type, Mounting surface position: 270° from port, Piston rod tip hole diameter: ø10

SMC's pin clamp cylinder series C(L)KQ series was designed with 4 body types for a broad range of installation conditions.  There are 55 types of guide pins available and an optional locking mechanism.  C(L)KQ series  has positioning and clamping at one time!  Precision adjustment of clamping height is possible by choosing the with-shim type.  Adjustment range: 0.5 to 3mm.Pin clamp cylinder

Pressure(MPa): 1, Additional Function: Speed Controller, Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P4DWSC, Lead Wire Length(m): 0.3, The number of the switches: 2 pcs., Specification: Built-in standard magnet type, Clevis width(mm): 12, Tip fitting: U-Shaped Knuckle Joint, Locking direction: Retraction locking

Pressure(MPa): 1, Additional Function: Speed Controller, Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P4DWSC, Lead Wire Length(m): 0.3, The number of the switches: 2 pcs., Specification: Built-in standard magnet type, Clevis width(mm): 12, Tip fitting: U-Shaped Knuckle Joint, Locking direction: Retraction locking

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 50MM CKQ, CLKQ DBL ACT, SW CAP, ACTUATOR, CKQ/CLKQ PIN CLAMP CYLINDER, NE, 50MM CKQ, CLKQ DBL ACT, SW CAP, 4.6297 lb

Pressure(MPa): 1, Additional Function: Speed Controller, Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P4DWSC, Lead Wire Length(m): 0.3, The number of the switches: 2 pcs., Specification: Built-in standard magnet type / with magnetic field resistant auto switch (for AC), Clevis width(mm): 12, Tip fitting: U-Shaped Knuckle Joint, Connector Type

Pressure(MPa): 1, Additional Function: Speed Controller, Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P4DWSC, Lead Wire Length(m): 0.3, The number of the switches: 2 pcs., Specification: Built-in standard magnet type / with magnetic field resistant auto switch (for AC), Clevis width(mm): 12, Tip fitting: U-Shaped Knuckle Joint, Connector Type

Pressure(MPa): 1, Additional Function: Speed Controller, Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P4DWSC, Lead Wire Length(m): 0.3, The number of the switches: 2 pcs., Specification: Built-in standard magnet type / with magnetic field resistant auto switch (for AC), Clevis width(mm): 12, Tip fitting: U-Shaped Knuckle Joint, Connector Type

Switch: D-P4DW--Solid State, 2-color Indication, Magnetic Resist., 2 Wire, Lead Wire or Prewired Connector: SC (0.3m Cord Length, M12-4 Pin Connector, 3 & 4 Out)

Pin Clamp Cylinder DSeries Series CKQGD/CKQPD Replacement Procedure is P.374 Construction CKQGDA50 The below figures indicate the CKQGDA50-RAL. CKQPDA50 The below figures indicate the CKQPDA50-RAL. Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L.

Pin Clamp Cylinder DSeries Series CKQGD/CKQPD Replacement Procedure is P.374 Construction CKQGDA50 The below figures indicate the CKQGDA50-RAL. CKQPDA50 The below figures indicate the CKQPDA50-RAL. Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L.

Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P4DWSC, Lead Wire Length(m): 0.3, The number of the switches: 2 pcs., Specification: Built-in standard magnet type, Clamp Side Lock: With lock, Mounting surface position: 90° from port, 270° from port, Port Screw Type: NPT, Guide Pin Diameter: