Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-M9E, D-M9EV (With indicator light) Auto switch model D-M9NE D-M9NEV D-M9PE D-M9PEV D-M9BE D-M9BEV Output signal turns on when no magnetic force is detected.

Mounting Height Auto Switch Proper Mounting Position (mm) D-Y59< D-Y69< D-Y7P D-Y7PV D-Y7D-Y7D-Y7BA D-Z7< D-Z80 D-B59W D-G39 D-G39C D-K39 D-K39C D-A5< D-A6< D-A3< D-A3D-A44 D-A44C Auto switch model D-G5< D-K59 D-G5NT D-G5D-K59W D-G5BA D-G59F D-M9< D-M9D-M9D-M9D-M9D-M9D-F5< D-J59 D-F59F D-F5D-J59W D-F5BA D-A9< D-A9D-J51 D-F5NT D-B5< D-B64 D-P3DW D-P4DW

58.0 35.5 55.0 32.5 56.5 33.5 53.0 30.0 CC 40 70.0 39.5 64.0 33.5 69.0 38.5 65.5 35.5 67.0 36.5 63.5 33.0 RB Auto switch model Bore size (mm) Operating Range Auto Switch Mounting Height D-C7 D-C80 D-H7 D-H7W D-H7NF D-H7BAL D-B5 D-B64 D-B59W D-G5NTL D-H7C J 20 25 32 40 D-G39 D-K39 D-A33 D-A34 Bore size (mm) D-C7/C80 D-C73C/C80C D-C73C D-C80C D-A44 8 10 9 10 D8 10 9 10 D-B5/B64 13 13 14 14

D C B A Non-standard Motors: The following motors will be mounted when a motor mounted type is specified.

A B C D Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) 10 20 30 40 50 60 1000 700 500 1000 700 500 Model Note LJ1H3031PD-200 to 1000LJ1H3031PD-1200LJ1H3031PD-1500LJ1H3032PD-200 to 1000LJ1H3032PD-1200LJ1H3032PD-15001000 700 500 900 700 500 1000 700 500 800 700 500 1000 700 500 700 700 500 900 700 500 650 650 500 800 700 500 600 600 500 Power supply: 100/110(V)AC 10% Compatible

30.0 40 70.0 39.5 64.0 33.5 69.0 38.5 65.5 35.5 67.5 37.0 67.0 36.5 63.5 33.0 Auto Switch Mounting Height (mm) D-C7 D-C8 D-H7 D-H7lW D-H7lF D-H7BAL D-B5 D-B6 D-B59W D-G5NTL D-H7C D-G39 D-K39 D-A33 D-A34 Bore size (mm) D-C73C D-C80C D-A44 HS HS HS HS HS 20 24.5 27 62 69.5 27.5 25 27 29.5 64.5 72 30 32 30.5 33 68 75.5 33.5 40 35 37.5 72.5 80.0 38 4.9-16

RESET B 8.3 P.41 RESET C OFF I/O STOP OFF OFF 8.5 ONP.44 RESET C D RESET C RESET D 66 No.JXC-OMU0004-A (M24V) RESET D RESET D 3.4 P.14 (C24V) RESET D RESET D ( E ) 67 No.JXC-OMU0004-A E ON E BK RLS E EEPROM EEPROM E 10 CPU CPU E 68 No.JXC-OMU0004-A 13. / 50mm ( ) 5m 5m 10% 15m 20% 69 No.JXC-OMU0004-A 14. / 14.1.

C c OFF OFF OFF ON OFF D d OFF OFF OFF OFF ON Power off Turn on the power E E OFF OFF OFF OFF OFF again When multiple alarms in alarm groups A to D occur, the relevant OUT 0 to 3 will be ON.

in Area C in the case of 15. 25, 32, 40, 50, 63 (mm) Auto switch model A B C D D-Y5 D-Y7P D-Y7W D-A9 D-Y5 D-Y7P D-Y7W D-A9 D-Y5 D-Y7P D-Y7W D-A9 D-Y5 D-Y7P D-Y7W D-A9 D-M9 D-F9W D-Z7 D-Z80 D-M9 D-F9W D-Z7 D-Z80 D-M9 D-F9W D-Z7 D-Z80 D-M9 D-F9W D-Z7 D-Z80 Bore size (mm) 25 32 40 50 63 18 21.5 23.5 27.5 29.5 99 108.5 124.5 148.5 158.5 43 46.5 48.5 52.5 54.5 74 83.5 99.5 123.5 133.5 23 26.5

A B C D Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) Model 10 20 30 40 50 60 LJ1H30ND-200 to 1000LJ1H30ND-1200LJ1H30ND-1500LJ1H30ND-200 to 1000LJ1H30ND-1200LJ1H30ND-15001000 1000 1000 1000 900 700 500 650 650 500 800 700 500 600 600 500 700 500 700 500 900 700 500 700 500 800 700 500 700 500 700 700 500 1000 700 500 Consult SMC if outside of the above conditions.

-X536 Dimensions Residual Pressure Release Valve (-X536) VP742(R)-5 D YZ1-04 -X536 VP742(R)-5 D YZ1-04 -M -X536 1/2" [2(A) port] Port size: 1/8" (Without check valve) Applicable tube O.D.: 6, 1/4" (With check valve) (External pilot port) 44.5 Safety limit switch 5.2 (For mounting) 3.5 VP500/700 X536 X538 X555 VG342 X87 Made by OMRON 7.5 4.5 33 3.5 108.4 20.5 (Max. 10) 224.2 Applicable cable

Valve with Detection of Main Valve Position VP500/700-X536, X538, X555 How to Order Residual pressure release valve VP X536 2 5 4 5 Z R D 1 03 M X538 VP 4 1 5 4 R 5 D Z 03 M A Dual residual pressure release valve Dual residual pressure release X555 VP 4 1 5 4 5 D Z 03 M valve with soft start-up function Throttle Thread Series Nil Variable throttle 10 1 fixed orifice 15 1.5 fixed orifice 20

Connector Socket Lead wire Hook 700 Series 10-SYJ300/500/700 Specific Product Precautions 3 Be sure to read before handling.

Note 4) D-Z7 and D-Y types cannot be mounted. 25 to 63 (mm) Auto switch model D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W A B C D D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-A9 D-M9 D-M9W D-A9 D-M9 D-M9W D-M9 D-M9W D-A9 D-M9 D-M9W D-A9 Bore size (mm) 25 32 40 50 63 19 23 18 98 94 99 42 38 43 75 79 74 22.5 26.5 21.5 107.5 103.5 108.5 45.5 41.5 46.5 84.5 88.5 83.5

BMY3-016 Auto switch model Tightening torque D-M9l(V) D-M9lW(V) 0.10 to 0.15 210 Solid State Auto Switch Direct Mounting Type D-M9N(V)/D-M9P(V)/D-M9B(V) RoHS Refer to SMC website for the details of the products conforming to the international standards.

Example) S2S2: Standard cable (2 m) + Driver (LECSS2) S2 : Standard cable (2 m) Nil : Without cable and driver Stroke (mm) Model 200 300 400 500 700 600 800 900 1000 1200 1500 2000 3000 LEJB40 LEJB63 D ) D D D ) ) D D D D ) ) D D ) ) D ) D D D D D 3: Strokes other than those shown above are produced as special order (1 mm increments). For auto switches, refer to pages 19, 20.