CHQ CHK CHN Mounting correctly Mounting incorrectly CHM CHM CHS
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 5 m Z (Example) M9NWZ None N (Example) H7CN 3 m L (Example) M9NWL Since there are other applicable auto switches than listed above, refer to page 14 for details. For details about auto switches with pre-wired connector, refer to the WEB catalog or Best Pneumatics No. 3.
LAT LEJS40 LEJS63 Applicable auto switches D-M9N(V)-900, D-M9P(V)-900, D-M9B(V)-900 D-M9NW(V)-900, D-M9PW(V)-900, D-M9BW(V)-900 LZ *4 Please consult with SMC for non-standard strokes as they are produced as special orders. LC3F2 * Specifications and dimensions for the 25A-series are the same as standard products.
Magnet: D (Built-in), Type: Pneumatic, Mounting: L (Axial Foot), Bore: 25mm, Port Thread: Rc, Stroke: 50mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod Boot: None
Magnet: D (Built-in), Type: Pneumatic, Mounting: L (Axial Foot), Bore: 25mm, Port Thread: Rc, Stroke: 300mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod Boot: None
Magnet: D (Built-in), Type: Pneumatic, Mounting: L (Axial Foot), Bore: 25mm, Port Thread: Rc, Stroke: 100mm, Cushion: A (Air Cushion), Rod End Thread: Male Rod End, Rod Boot: None
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 210, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushion, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 220, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushion, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 220, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 225, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushion, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 225, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 230, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushion, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 240, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushion, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushion, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 265, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 275, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 290, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushion, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushion, Specification: Built-in magnet, Port thread type: Rc, Auto