2 (Different sides) 1 Auto switch mounting style No. of auto switches mounted D-A7 D-A80 D-A73C D-A80C NCM 90 55 50 15 10 105 60 60 15 10 105 65 65 15 10 35 10 5 45 10 5 40 15 10 45 5 5 30 5 5 55 15 10 40 15 10 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 D-C7 D-C80 NCA D-A7H D-A80H Band mounting style (6, 10, 16) DD-H7 D-H7W D-H7BAL D-H7NF Rail mounting style (10, 16) D-A79W -X D-F7 D-J79 20D-C73C
switch model Same side n Different sides 1 Same side C95 D-C7 D-C80 D-H7 D-H7W D-H7BAL D-H7NF D-C73C D-C80C D-H7C 10 50 15 50 + 45 (n 2) n 2 2 15 + 45 ( ) (n = 2, 4, 6) CP95 10 60 15 60 + 45 (n 2) NCM NCA n 2 2 15 + 50 ( ) (n = 2, 4, 6) 10 65 15 65 + 50 (n 2) Dn 2 2 D-B5/B6 D-G5NTL 15 + 50 ( ) (n = 2, 4, 6) 75 10 15 -X 75 + 55 (n 2) n 2 2 20 + 50 ( ) (n = 2, 4, 6) D-B59W 15 75 20 20D-A3A
-X Auto switch Bore size (mm) 40 32 50 63 80 100 20D-A5/A6 D-J5/F59F BT-06 BT-05 BT-06 BT-03 BT-05 BT-03 Data D-A3/A44 D-G39/K39 BMB1 -100 BMB1 -063 BMB1 -080 BMB2 -040 BMB1 -050 BMB2 -032 D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV BA4 -063 BA4 -063 BMB4 -050 BMB4 -050 BMB4 -032 BMB4 -032 BMB3T -080 BMB3T -080 BMB3T -050 BMB3T -050 BMB3T -040 BMB3T -040 D-P5DWL [Mounting screws set made of
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø16 mm, Stroke: 20 mm, Rod End Thread: With Thread, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, 0.5M
Magnet: D (Built-in), Mounting: D (Clevis), Bore Size: Ø16 mm, Stroke: 20 mm, Rod End Thread: With Thread, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, 0.5M
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 32mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: D (Double Acting), Rod End: Round Bar Style, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: A96--Reed, DC Volt, LED, Horizontal
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 50mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A96--Reed, DC Volt, LED, Horizontal
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A96--Reed, DC Volt, LED, Horizontal
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A96--Reed, DC Volt, LED, Horizontal
Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 32mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Round Bar Style, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Basic, Bore Size: Ø16 mm, Stroke: 20 mm, Rod End Thread: With Thread, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: -, Number: -, Option: -
Magnet: Built-in, Mounting: Clevis, Bore Size: Ø16 mm, Stroke: 20 mm, Rod End Thread: With Thread, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: -, Number: -, Option: -
Magnet: Built-in, Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 50mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector:
Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number:
Magnet: Built-in, Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector:
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 mm, Stroke: 20 mm, Rod End Thread: B (Without Thread), Auto Switch: A96--Reed, DC Volt, LED, Horizontal, 0.5M
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø16 mm, Stroke: 20 mm, Rod End Thread: B (Without Thread), Auto Switch: A96--Reed, DC Volt, LED, Horizontal, 0.5M
Magnet: Built-in, Mounting: Basic, Bore Size: Ø16 mm, Stroke: 20 mm, Rod End Thread: Without Thread, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: -, Number: -, Option: -
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: A96,