SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2YL16-100Z-A93-B"

Proper Auto Switch Mounting Position (Detection at stroke end) C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Series MY2C Series MY2H Series MY2HT (mm) D-M9, D-M9V (mm) D-M9, D-M9V (mm) D-M9, D-M9V A A A B B B Bore size 16 25 40 Operating range Bore size

A B A 22 22 U U (24.5) ( ): For D-A93 type D-H7 D-H7W D-H7NF D-H7BAL D-C7 D-C8 RSQ RSG RS MI U U B A 26 B A 29 D-C73C D-C80C D-H7C U U B A 36.7 B A 38.2 Auto Switch Proper Mounting Position Auto Switch Mounting Height Auto switch model (mm) (mm) Auto switch model D-C7 D-C80 D-H7 D-H7W D-H7NF D-H7BAL D-C7 D-C80 D-C73C D-C80C D-H7BAL D-H7W D-H7 D-H7C D-A9 D-M9 D-M9W D-A9 D-M9 D-M9W D-H7C

LD Piping port P Operating direction A 7 Piping port P Operating direction B W K G With switch rail Q + Stroke Z + Stroke Piping port P (plug) Operating direction B HS CR HR Plug 22 8 Piping port P Operating direction B Piping port P (plug) Operating direction B 8 Piping port P Operating direction A 16 19.5 16 Plug REBR15 REBR15 (mm) A B C CB CR D F G GP GW H HA HB HC HP HR HS HT Model REBR15

AS600 (258) AS420 (102) AS600 (258) AS600 (258) AS600 (258) AS800 (586) AS500 (123) 1-A 2-B 1-C 2-A 2-B 1-A 2-B 2-A 2-B 2-B 2-B 2-B 2-B 1-A 2-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 2-B 2-A 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 20 8, 10 1/4 500 9.5 0 1,000 2,000 3,000 Maximum speed Vmax (mm/s) 50 12, 16 1/4, 3/8 1000 19 63 Composed effective area So (mm2) Composed effective area So (mm2)

38 35 42 40.5 A 33 32.5 34 31 38 36.5 49.5 48.5 A B A B A B A B 20 25 32 40 50 63 80 100 B 24 (32) 24.5 (32.5) 25 (33) 27 (36) 32 (44) 33.5 (45.5) B 14.5 (22.5) 15 (23) 15.5 (23.5) 17.5 (26.5) 22.5 (34.5) 24 (36) 29 (43) 30 (44) B 20 (28) 20.5 (28.5) 21 (29) 23 (32) 28 (40) 29.5 (41.5) B 16 (24) 16.5 (24.5) 17 (25) 19 (28) 24 (36) 25.5 (37.5) 30.5 (44.5) 31.5 (45.5) Hs 27.5 30 33.5

MGC MGF CY1 q B MY1 Normally ON w * Adjust the switch position according to load and speed.

7 2 38 12 6.6 11 12 A B 34 16 34 16 H Cross section AA Cross section BB (NN-1) X H G (mm) Note) Refer to "Dimensions" of MXS25 on P. 64 for one with shock absorber as symmetric.

JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage.

Rotational axis B d D I m kgm I = m kgm 8 8 Gear: I a + b I = m kgm IB = I + I + I kgm 12 Substitute the moment of inertia IB for rotation around shaft B with the moment of inertia IA for rotation around shaft A. Gear: I IA = (A/B)IB [A/B: Gear tooth ratio] Find the actual moment of inertia.

U B A CHA B A Related Products D-F7 D-F7W D-J79 D-J79W D-A7 D-A7H D-A8 D-A8H D-F7V D-F7WV D-F7BA D-F7BAV D-F7NT D-F79F D-J79C D-A73C D-A80C 32 to 100 DApprox. U B A Approx.

A C MTS D-F9W, D-M9 D-A93 D-A90, D-A96 D-M9V, D-F9WV Bore size (mm) CXSJ15 to 32 B D A 15.5 25.5 31.5 39 40 49 D 9.5 7 0 3 5 5.5 C 9.5 19.5 25.5 33 34 43 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 A 15.5 25.5 31.5 39 40 49 A 19.5 29.5 35.5 43 44 53 C 11.5 21.5 27.5 35 36 45 D 5.5 3 4 7 9 9.5 D 8 5.5 1.5 4.5 6.5 7 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 C 13.5 23.5 29.5 37 38 47 C 11 21 27 34.5 35.5

A C MTS D-F9W, D-M9 D-A93 D-A90, D-A96 D-M9V, D-F9WV Bore size (mm) CXSJ15 to 32 B D A 15.5 25.5 31.5 39 40 49 D 9.5 7 0 3 5 5.5 C 9.5 19.5 25.5 33 34 43 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 A 15.5 25.5 31.5 39 40 49 A 19.5 29.5 35.5 43 44 53 C 11.5 21.5 27.5 35 36 45 D 5.5 3 4 7 9 9.5 D 8 5.5 1.5 4.5 6.5 7 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 C 13.5 23.5 29.5 37 38 47 C 11 21 27 34.5 35.5

Low Speed Cylinder Double Acting, Single Rod Series CQSX 12, 16, 20, 25 How to Order CQSX D B 20 30 Without auto switch 30 F9BW B 20 CDQSX D With auto switch Number of auto switches Built-in magnet 2 pcs. 1 pc. n pcs.

Example Rail mounting style CDJ2XB10-45-A Band mounting style CDJ2XB16-60-B Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.

For D-A93, only outward electrical entry (D dimension) is available. Dimensions in parentheses apply to 12-CXSJ6. CXSJ10 / CXSJ10 11122122Note 2) D B Note 3) (mm) D-M9 34 (35.5) 3.5 (2) 24 (25.5) 6.5 (8) D-A93 30 (31.5) 25.5 (27) 5 (6.5) Symbol A B C D Note 1) The above mentioned values are indicated as a guide for auto switch mounting positions for stroke end detection.

8 Stainless steel Wear ring B Special resin Cylinder tube w !

8 Stainless steel Wear ring B Special resin Cylinder tube w !

Note) A B A B Specifications are the same as standard products with the exception of lead wire specifications. Lead wire: For D-F8, F9 type 2.7, 0.15 mm2, 3 cores (Brown, Blue, Black), 2 cores (Brown, Blue) For other model nos. 3.4, 0.15 mm2, 3 cores (Brown, Blue, Black), 2 cores (Brown, Blue) Dimensions are identical with D-F5 type, G5 type, J59 type, K59 type.

Auto switch model D-Y59m D-Y69m D-Y7P D-Y7PV D-Y7H D-Y7mW D-Y7mWV D-Y7BA D-Z7m D-Z80 D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA D-M9mAV D-A9m D-A9mV D-F5m D-J59 D-F59F D-F5NTL D-A5m D-A6m D-A59W D-G39 D-K39 D-A3m D-A44 D-P3DWA D-P4DW A B A B A B A B A B A B A B A B A B A B 32 13.5 10.5 9.5 6.5 10 7 15 12 3.5 0.5 7.5 4.5 3.5 0.5 7 4 9 6 6.5 3.5 40 10.5 14 6.5 10 7 10.5 12 15.5 0.5 4 4.5 8 0.5 4 4

B Stroke B-A Stroke B operation 1) Initial state (0 stroke position) Stroke B Stroke A C 2) Operation When the air pressure is supplied from the C port, the rod operates the stroke B. B B A Stroke B A C Stroke B Stroke A Double output is possible.