SMC Corporation of America
Elite Part Number Search
Search Results "CDBXWM25-50-F7BV"

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 32mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting/Spring Loaded, Rod End: Lever Type, Adjustable Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F7BV--Solid State, Gen.

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 20mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Round Bar Style, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F7BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: Double Acting, Rod End: Round Bar Style, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F7BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 20mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Round Bar Style, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F7BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 16mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 15mm, Action: Double Acting, Rod End: Round Bar Style, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F7BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 16mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 15mm, Action: Double Acting, Rod End: Chamfered, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F7BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 20mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Round Bar Style, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F7BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: Double Acting, Rod End: Round Bar Style, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F7BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting/Spring Loaded, Rod End: Lever Type w/Lock Mechanism, Adjustable Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F7BV--Solid State, Gen.

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 32mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Roller Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F7BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: -, Cushion: Shock absorber, Operating Pressure(MPa)

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: -, Cushion: Shock absorber, Operating Pressure(MPa)

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: -, Cushion: Shock absorber, Operating Pressure(MPa)

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: -, Cushion: Shock absorber, Operating Pressure(MPa)

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: -, Cushion: Shock absorber, Operating Pressure(MPa)

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: -, Cushion: Shock absorber, Operating Pressure(MPa)

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: -, Cushion: Shock absorber, Operating Pressure(MPa)

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: -, Cushion: Shock absorber, Operating Pressure(MPa)

Cylinder: Auto Switch/Housing Mount, Bearing Style: Slide Bearing, Bore Size: 25mm, Stroke: 50mm, End Lock: None, Auto Switch: A73C--Reed, DC Volt.>5,<24, LED, Connector, Vertical, 0.5M, Lead Wire or Prewired Connector: -, Number: -

Cylinder: Auto Switch/Housing Mount, Bearing Style: Slide Bearing, Bore Size: 25mm, Stroke: 50mm, End Lock: None, Auto Switch: J79W--Solid State, 2-color Indication, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: -, Number: -