DC () Blue D-F9PW D-Y7PW D-F9P D-Y7P DC (+) Brown DC (+) Brown OUT Black OUT Black DC () Blue DC () Blue Indicator light ON D-F9BW D-Y7BW D-F9B D-Y59B OUT (+) Brown OUT (+) Brown Operating range OFF Red Green Indicator Red Optimum operating position OUT () Blue OUT () Blue Contact Protection Box/CD-P1 1, CD-P12 Internal circuit D-A9, Z7, Z8 The above auto switches do

Contact Protection Box/CD-P11, CD-P12 The D-Z7, D-Z8 and D-A9 type switches do not have built-in contact protection circuits. Use a contact protection box in cases such as with an induction load, when the lead wire is longer than 5m or with 100VAC. 1 Operating load is an induction load. 2 Wiring to the load is 5m or longer.

low speed actuation (no control of cylinder output) Example 2) Low speed with output control Precision restrictors Solenoid valve ITV (Electro-pneumatic regulator) Mist separator (0.01 m or less) (0.3 m or less) Mist separator (0.3 m or less) Air filter (5 m or less) IR (Precision regulator) W Air filter (5 m or less) IR (Precision regulator) W When performing control of cylinder output, do

Do not subject the gauge to impacts, such as dropping, during transportation and mounting. This can cause loss of indication accuracy. 2. Do not use in locations with high temperature and humidity. This can cause malfunction. 3. When screwing the pressure gauge into place, be sure to apply your wrench on the square wrench flats.

SG 12 Note 1) Do not orient diodes incorrectly. The amp will fail if connected incorrectly. Servo ON Note 2) Wiring for a standard cable less than 10m. When the cable length is 10m or longer, four lines each of P5 and LG wires should be connected in parallel.

Make sure that the lead wires do not interfere with the slide table at any stroke range. Lead wire cover Figure 3.

(Mp,My values do not apply to this example.) Mr=W (L3 + C) = 10 (.05 + 0.014) =0.64 [N m] W Mr 2 =Mr/Mr max. =0.64/12 =0.053 Mr: Mr max. value is from at Va=300mm/s L3+C Mey=1/3 We (L2 + B) From V = 1.4 Va We = W V = 4/100 10 1.4 300 = 168 [N] Mey = 1/3 168 (0.5 + 0.037) = 4.9 [N m] 3 = Mey/Mey max. = 4.9 / 14.3 = 0.343 (3) Dynamic moment Examine Mey.

Perform changes of the detection position under the same conditions as step 3. 24 Series RSDG Auto Switch Hysteresis Contact Protection Boxes/CD-P1 1, CD-P12 D-C7/C8, D-C73C/C80C The above auto switches do not have internal contact protection circuits. 1. The operating load is an induction load. 2. The length of wiring to the load is 5m or more. 3.

(Do not adjust more than 2mm, as it will not be possible to obtain smooth acceleration and deceleration.) Do not adjust based on the stopper's movement, as this can cause cylinder damage. Stroke Adjustment Loosen the round head Phillips screws, and remove the top covers and dust covers (4pcs.).

Single action positive operation X View M A Automatic / Manual change-over screw (Built-in bleed restriction) Sensitivity adjusting screw (Adjusts GAIN) Stopper screw (Do not move) (15) Diaphragm valve SUP OUT2 OUT1 X (1) Pilot valve Supply valve A Supply valve B (8) Feedback lever (9) Span adjusting lever (7) Exhaust valve Span adjusting lever shaft EXH. (4) Counter weight Diaphragm For

Before piping and screwing in couplings, please make sure that sludge trom pipe threading and sealing materials do not go into the pipe. When seal tape is used, tape winding should be done so that 2 threads are left untaDed on the end.

Please make sure that operating conditions do not cause problems since the use of FEP tubing under chemical environment is unsecured.

Do not service or attempt to remove product and machinery/equipment until safety is confirmed. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed.

Do not supply or discharge air suddenly. This will cause the temperature to decrease due to air expansion, and the temperature may exceed the operating temperature limit of the air tank. If flow speed becomes faster, a loud noise may be generated by the friction inside the tube.

2 3 L0 V 4 C/Q (IO-Link)/1(SIO) -17No.PS-OMV0003CN-G NPN 2 DC(+) OUT1 OUT2 DC(-) PNP 2 DC(+) OUT1 OUT2 DC(-) IO-Link L+ C/Q IO-Link DO L-18No.PS-OMV0003CN-G [] 3 0.2 [] / UP DOWN OUT1 OUT1 OUT2 OUT2 [F10]30 () SET 1~3 SET 3~5 SET [] [] [] [3 ] (25 ) (55 ) (23 ) (21 ) 30 () 3 -19No.PS-OMV0003CN-G ON OFF ON P_1 H_1 ON OFF ISE70 ISE71 [P_1] OUT1[MPa] 0.500 0.800 [

.(5%) (0~1MPa 0.001MPa 1/1000) () () F () ripple -14No.PS-OMV0008CN-E ( M46L(2)) 0.760.1 Nm A(ZS-50-A) A M4X6L B(ZS-50-B) B M4X6L -15No.PS-OMV0008CN-E 1.50.1 Nm (ZS-48-A) -16No.PS-OMV0008CN-E -02-N02 8~12 Nm -F02 4~5 Nm 24 () -17No.PS-OMV0008CN-E ()336 336 -18No.PS-OMV0008CN-E FG M12 M12 (Port Class A) 1 DC(+) DC1224 V 2 OUT2 2 3 DC(-) 0 V 4 OUT1 1 IO-Link 1 L+ DC1830 V 2 DO

VQC1000/2000 series valves do not come with mounting screws or gaskets. For VQC4000/5000 series valves, when a valve is ordered individually, it comes with a mounting screw but no gasket. VQC1000/2000 series valves do not require separate mounting screws as there are clamp screws built into the manifold.

VQC4000/5000 series valves do not have common polarity.
② For manifolds with serial transmission kits, whether the valves are positive common or negative common depends on the type of protocol. For VQC1000/2000 series valves, install valves with the same common specification as the common specification of your protocol.