Example: VEX1300-03 G36-4-01 (Constructive symbol) 5.1-1 VEX1 How to Order 1 03 D 3 1 0 B VEX Regulator valve B Bracket Option F Foot (Only VEX110) G Gauge When specifying more than one option, combine symbols in alphabetical order. 0 Air operated Operating style 1 External pilot solenoid None Indicator light and surge voltage suppressor S Surge voltage suppressor Z Indicator light and
CH kPa MPa kPa MPa MPa kPa kPa MPa kPa MPa OUT1 OUT2 CH 1 2 3 4 P R E S S U R E Copy function (page 14) Each channel's information can be copied to another channel.
(Pattern for 3 digits on the right) Characters Q, X, Z, /, or cannot be displayed. (Pattern for 1 digit on the left) Characters A to Z can be displayed (the same as the 3 digits on the right). -54No.PS-OMU0009-D
Special function setting [F90] Setting of all functions All functions can be set in turn.
Number of auto switches Nil 2pcs. s 1pc. n npcs. Applicable Auto SwitchesRefer to the website catalog for detailed auto switch specification.
How to Calculate the Flow Rate S 6 V For obtaining the flow rate, refer to page 3-1-10. Applicable cable O.D. 3.5 to 7 (Reference) 0.5 mm2 2 core and 3 core wires equivalent to JIS C 3306 12 V DC None Z Precautions on connection for 24 VDC or more Grommet type should be connected as following; Red lead wire for (+) side, Black lead wire for () side respectively.
None Coil Z LED No.2() Continuous Duty Type: VK33E No.1 Varistor Varistor Recommended for continuous duty with long time loading. S Coil Coil Coil DC 6V 12V No.2 Caution No.1 1. This model is for continuous duty, not for high cycle rates. But even in low cycle rates, if energizing the valve more than once a day, please consult with SMC. 2.
Applicable cable O.D. 3.5 to 7 (Reference) 0.5 mm2 2 core and 3 core wires equivalent to JIS C 3306 24 V No.2() Black() 48 V No.1 Diode DC None Z Coil LED No.2 No.1 S Coil Coil Varistor Varistor 6 V No.2 12 V No.1 DC None Z Coil No.2 Precautions on connection for 24 VDC or more Grommet type should be connected as following; Red lead wire for (+) side, Black lead wire for () side respectively
~0.6Nm U +-( ) 1V ( ) +DIN
The moving speed of the first operation after the recovery is 50mm/s. 38
or less IP40 Operating: 0 to 60C, Stored: 10 to 60C (With no condensation and no freezing) Operating/Stored: 35 to 85%RH (With no condensation) 10 to 500 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s2 acceleration, in X, Y, Z directions for 2 hrs. each (De-energized) 980 m/s 2 in X, Y, Z directions, 3 times each (De-energized) 3% F .S. or less 1000 VAC for 1 min.
Connector pin numbers -19No.PS-OMU0003-D Internal circuit and wiring examples Z/ISE20A(F)---Output specification -S/-R (Analog output mode) Switch output NPN open collector output type-2 output Max. 28 V, 80 mA Residual voltage 1 V or less R: Analog output 1 to 5 V Output impedance 1 k S: Analog output 4 to 20 mA Max. load impedance Power supply voltage 12 V: 300 Power supply voltage 24
Connector pin numbers -20No.PS-OMU0006-D Internal circuit and wiring examples Z/ISE20B(F)---Output specification -S/-R (Analog output mode) Switch output NPN open collector output type-2 output Max. 28 V, 80 mA Residual voltage 1 V or less R: Analog output 1 to 5 V Output impedance 1 k S: Analog output 4 to 20 mA Max. load impedance Power supply voltage 12 V: 300 Power supply voltage 24
10-/21-AR20-B30-B: Max. 3.5 10-/21-AW40-B: Max. 5 AR50-B/60-B 10212 x P1 (Port size) A BB Pressure gauge (Option) C H K IN OUT B Q AA Applicable tubing 6/4 P2 (Pressure gauge port size) R F J M D J U Bracket (Option) T N S Optional specifications Standard specifications Model Round type pressure gauge Bracket mounting size Panel mount P1 P2 A B Note 1) C D Q R S T U V W Y Z F J K AA BB H
S A93 MGT MY Table unit/ Number of auto switches CY Table unit/ Auto switch S 1 pc.
L B + Stroke K A + Stroke M G J W 16 Minimum lead wire bending radius 10 Auto switch Q F 4 x N through H thread effective depth C 2 x M3 x 0.5 (Port size) I D M E Z L B + Stroke K A + Stroke M G J W Standard [mm] Bore size Stroke range Without magnet for auto switch With magnet for auto switch C D E F G H I J K L M N Q W Z A B A B 12 5 to 30 19.5 16 23 19.5 6 6 23 4 21.5 M3 x 0.5 26 1.5 5
(Display pattern for 3rd, 4th, 5th, 8th and 9th digit from the left) Characters Q, X, Z, /, or cannot be displayed. (Display patter for 1st., 2nd., 6th., and 7th digit) Characters A to Z can be displayed (the same as the 3 digits on the right).
Rated voltage For DC 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC B: Locking slotted type Electrical entry 24 VDC, 12 VDC, 6 VDC, 5 VDC, 3 VDC Grommet L plug connector M plug connector G: 300 mm lead wire L: 300 mm lead wire M: 300 mm lead wire MN: Without lead wire Light/Surge voltage suppressor Nil S Z R U Without light/surge voltage suppressor With surge voltage suppressor With light/surge
D-X Table (1) Allowable Kinetic Energy At Piston Impact Unit: [J] Individual -X Allowable kinetic energy 50 to 500mm/s 20 25 32 40 50 63 80 100 Technical data Piston speed 0.055 0.09 0.15 0.26 0.46 0.77 1.30 2.27 789
Air Cylinder: Standard Type Double Acting, Single Rod CG1 Series 20, 25, 32, 40, 50, 63, 80, 100 RoHS How to Order 100 CG1 20 N B Z N B 20 Z Bore size 100 CDG1 M9BW With auto switch With auto switch (Built-in magnet) Pivot bracket Made to Order Mounting Nil None For details, refer to page 293. 20 20 mm 25 25 mm 32 32 mm 40 40 mm 50 50 mm 63 63 mm 80 80 mm 100 100 mm N Pivot bracket is shipped
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-12 Connection of RS-232C HRS-R Series 3.3 Installation 3-19 HRX-OM-W058 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.