Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 1, Output Specification/Temperature Sensor: Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C, Bracket: None, Calibration Certificate

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1, Output Specification/Temperature Sensor: Out 1: NPN, Out 2: Flow Rate: NPN, Temp.: None,Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C, Bracket: None, Calibration Certificate

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1, Output Specification/Temperature Sensor: Out 1: PNP, Out 2: Flow Rate: PNP, Temp.: None, Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C, Bracket: None, Calibration Certificate

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1, Output Specification/Temperature Sensor: Out 1: PNP, Out 2: Flow Rate: PNP, Temp.: None, Temperature Sensor: None, Lead Wire: w/o Lead Wire and M8 Connector, Unit Specification: Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C, Bracket: None, Calibration Certificate

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 1, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: Calibration Certificate, Made

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 11 (10 to 100 L/min), Port Size, Pipe O.D.: 25 (Port Size: 25A, Pipe O.D.: 32mm), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration Certificate), Made to Order: X109 (EPDM Seal Material

20 750 kPa 30 kPa 50 kPa 50 kPa 350 kPa 10 70 kPa 70 kPa 350 kPa 00 20 40 60 80 100 Flow [L/min] Flow [L/min] Flow Rate Characteristics (Reference Data) PF2M710(-L) PF2M705(-L) PF2M725(-L) 10 L/min 5 L/min 25 L/min 12 10 8 6 4 2 0 0 2 4 6 8 10 12 14 30 25 20 15 10 5 0 0 2 4 6 8 10 12 14 6 5 150 kPa 350 kPa 150 kPa 150 kPa Flow [L/min] Flow [L/min] Flow [L/min] 4 3 350 kPa 350 kPa 2 750 kPa

Absorbed Energy Max. absorbed energy (J) Collision speed (m/s) Model 1 2 3 4 5 10 20 30 40 50 60 70 80 Soft type RJ0604 0.05 to 1 0.5 H : 0.05 to 2/L : 0.05 to 1 RJ0806H/L 1 H : 0.05 to 2/L : 0.05 to 1 RJ1007H/L 3 H : 0.05 to 2/L : 0.05 to 1 RJ1412H/L 10 H : 0.05 to 2/L : 0.05 to 1 RJ2015H/L 30 H : 0.05 to 1.5/L : 0.05 to 1 RJ2725H/L 70 Short stroke type RJ0805 0.05 to 1 0.5 RJ1006 0.05 to

Bore size [mm] Dd9 L l m d Part no.

F F 1 2 1 2 MHL2-10DZ MHL2-16DZ MHL2-16D Z MHL2-10D Z 60 60 25 25 Pressure 0.6 MPa Gripping force [N] Gripping force [N] Gripping force [N] Gripping force [N] Pressure 0.6 MPa 50 50 20 20 Pressure 0.6 MPa 0.5 MPa Pressure 0.6 MPa 0.5 MPa 40 40 15 15 0.4 MPa 0.5 MPa 0.5 MPa 0.4 MPa 0.4 MPa 30 30 0.4 MPa 10 10 0.3 MPa 20 20 0.3 MPa 0.3 MPa 0.3 MPa 0.2 MPa 5 5 10 10 0.2 MPa 0.2 MPa 0.2 MPa 10

If there is something you do not know, please contact SMC. 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 10 102 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 101 102 103 104 105 106 107 108 109 Pa Vacuum piping direction: if the system uses a vacuum pump, we ask that you install the vacuum pump on the secondary side.

Model: 43 (AC or DC Mode, for IZTN43 Nozzle), Type: L (IO-Link), DIN Rail Mounting Bracket: Y (DIN Rail Mounting Bracket Included)

Pressure: 2 (For Low Pressure (0~101kPa)), Port Size: R06 (R06 Reducer Type), Option: L (Sensor Cable)

Pressure: 2 (For Low Pressure (0~101kPa)), Port Size: R07 (1/4" Reducer Type), Option: L (Sensor Cable)