SMC Corporation of America
Elite Part Number Search
Search Results "CS2D125TN-250"

When two elements (250 mm) are used, be careful not to lose the joint which seals the elements.

Settings1 Content 2 3 OFF OFF 1 Mbps (Default setting) OFF ON 500 kbps ON OFF 250 kbps ON ON 125 kbps : This function is for extension in the future.

Insulation resistance 500 VDC 10 M or more Operating environment No corrosive gas Pollution degree Pollution degree 3 Enclosure IP67 Weight Approx. 250 g Applicable standard UL/CSA, CE Electrical specifications Item Specification Rated voltage 24 VDC Range of power supply voltage Power supply for input and control: 24 VDC10% Power supply for output: 24 VDC+10%/-5% Power supply for input and

Enclosure IP65 Ambient temperature range Operation: -10 to 60 oC, Storage: -20 to 70 oC (No condensation or freezing) Environ ment Ambient humidity range Operation, Storage: 35 to 85%RH (No condensation) Withstand voltage 250 VAC, 1 minute, Between lead block and case Insulation resistance 50 M or more at 50 VDC Between lead block and case Temperature characteristic 2% F.S. or less (0 to

socket) EX500-DXPB: M12 connector (5 pin, socket) Short circuit protection Available Enclosure rating IP67 Body material PBT Operating temperature range Operation: -10 to 50 oC, Storage: -20 to 60 oC (No condensation or freezing) Operating humidity range Operation, Storage: 35 to 85%RH (No condensation) Operating atmosphere No corrosive gas Standard CE mark, UL(CSA), RoHS Weight EX500-DXPA: 250

Settings1 Content 3 4 OFF OFF 1 Mbps (Default setting) OFF ON 500 kbps ON OFF 250 kbps ON ON 125 kbps : This function is for possible extension. Keep the default setting of 1 Mbps. -22No.EX-OMN0028-B HOLD/CLEAR switch: Sets the output status when the Fieldbus has a communication error or is in idling state. Settings2 Content 4 OFF Output is Off.

Parameter Initial value Initial value Selection range (value) 2 (mm) Value/Range Setpoint 1 (SP1) 250 12.5 mm D-MP025 0 to 500 Setpoint 2 (SP2) 230 11.5 mm Measuring range 0 to 500 25 mm Setpoint 1 (SP1) 500 25 mm D-MP050 0 to 1000 Setpoint 2 (SP2) 480 24 mm Measuring range 0 to 1000 50 mm Setpoint 1 (SP1) 1000 50 mm D-MP100 0 to 2000 Setpoint 2 (SP2) 980 49 mm Measuring range 0 to 2000 100

Internal C 12 31 56 83 gripping force Open/close stroke (Both sides(mm) 4 6 10 14 Note 2) Weight (g) D 60 130 250 460 SC 60 130 255 465 Note 1) Values based on pressure of 0.5 MPa, gripping point L=20 mm, at center of stroke. Note 2) Values excluding weight of auto switch. 4 - 2. Mounting of Auto Switch 2-1.

(humidity) oC Inlet air pressure MPa 250 Indoor 1 phase 100VAC 1 phase 200VAC 1 phase 100VAC 3 phase 200VAC 3 phase 200VAC 3 phase 200VAC (50/60Hz) (50/60Hz) (50/60Hz) (50/60Hz) (50/60Hz) (50/60Hz) 50Hz 55 58 55 50 90 204 60Hz 58 65 65 60 130 244 50Hz 0.8 0.43 0.8 0.4 0.4 2.0 60Hz 0.81 0.46 0.9 0.35 0.45 2.0 Power supply Electric specifications Power consumption Current 255 1.5 300 Proof

Pressure Flow characteristics IZG10--01IZG10--02 Mode setting switch: Continuous blow 500 450 400 Indicator (maximum) Flow rate [L/min(ANR)] 350 300 Indicator (7) 250 Indicator (6) 200 150 Indicator (4) 100 Indicator (2) Indicator (0) 50 0 0 0.1 0.2 0.3 0.4 0.5 0.6 Supply pressure [MPa] 6.

Specifications Table. 6-1 Specifications Description Item EX245-SPN1 EX245-SPN2 General Dimensions (W x L x H) in mm 85 x 148.5 x 130 Weight 1000 g or less Housing materials Aluminium, PBT Max. number of modules 8 Max. number of digital inputs 128 Max. number of digital outputs 64 (independent of solenoid valves) Electrical Internal current consumption at 24 VDC (Via US1) 300 mA or less 250

ISE80 ISE80H ZSE80 ZSE80F (positive pressure) (positive pressure) (vacuum) (compound) Enclosure IP65 Ambient temperature Operation: 0 to 50 oC, Storage: -10 to 60 oC (No condensation or freezing) Environment Ambient humidity Operation, Storage: 35 to 85% RH (No condensation) Withstand voltage 250 VAC for 1 minute Between wires and case Insulation resistance 2 M or more (50 VDC by megameter

IP67 2 Medium temperature 0 to 50 C -5 to 80 C (No condensation, No freezing) (No condensation, No freezing) Operation: 0 to 50 C Storage: -10 to 60 C Operation: -5 to 50 C Ambient temperature Storage: -10 to 60 C Environ ment (No condensation, No freezing) (No condensation, No freezing) Ambient humidity Operation, Storage: 35 to 85%RH (No condensation) Withstand voltage 1000 VAC, 1 min. 250

Installation height Install the ionizer within the distances indicated below from the object that is to be neutralized Distance from the ionizer to the object to be neutralized [mm] Ion generation frequency Hz With air purge (Note) Without air purge 400 to 2000 400 to 500 3 300 to 2000 300 to 400 5 300 to 2000 300 to 400 10 200 to 2000 200 to 300 15 200 to 2000 200 to 300 20 150 to 2000 150 to 250

SPECIFICATIONS Model AL10-A AL20-A AL30-A AL40-A AL40-06-A AL50-A AL60-A Port size M5 1/81/4 1/43/8 1/43/81/2 3/4 3/41 1 Air Fluid 1.5 MPa Proof pressure 1.0 MPa Max. operating pressure Ambient and fluid temperature -5 60 (Should be no freezing) 1/430 3/840 1/250 15 Min. operating flow Note1) L/min(ANR) 50 1/430 3/840 4 190 220 Bowl capacity cm3 7 25 55 135 Class 1 turbine oil (ISO VG32)

. + = 4 . 1 = a V V 2 V m M E k 2 Ek: Kinetic energy (J) M : Mass of object being transported (kg) m : Mass of moving parts of cylinder (kg) V: Maximum speed (m/s) Va: Average speed (m/s) Mass of moving parts of cylinder (kg) Bore size Standard stroke (mm) (mm) model 20 25 30 40 50 75 100 125 150 175 200 250 300 350 MLGPM20 0.40 0.42 0.45 0.47 0.59 0.65 0.71 0.77 0.83 0.89 1.08 1.20 1.31

Flange) Fn J H B G A Unit: mm A Model A B C D E Fn G H J XLG-16 40 110 38 1 30 17 40 26 XLG-25 50 120 48 1 12 40 26 39 27.5 XLG-40 65 171 66 2 11 55 41 63 36 10 XL*-OMI0010-E 4-2Size 50,63,80,100,160 C E D C E E (KF Flange) (K Flange) Fn Fd J K H B A G A Unit: mm Model A B C D E Fn Fd G H J K XLG-50-1 70 183 80 31 10.5 75 52 77 29 10.5 XLG-63-1 88 209 100 39 11 87 95 70 76.5 36 9 XLG-80-1 90 250

Hole Thru 1 2 2 1/2 3 3 1/2 4 5 5 1/2 6 7 8 10 1/16 .078 3/32 1/8 5/32 .170 3/16 7/32 1/4 5/16 3/8 1/2 .055 .059 .081 .089 .104 .125 .140 .156 .177 .250 .290 .391 5. Orifice Fittings Many of our small brass fittings such as B1, B2, T1, T2, etc., are available as orifice fittings. In the case of Tees, the branch and/or one end of the run may be an orifice.

100 25st 50st 30 25, 50st MGT 20 50 40 10 30 5 4 3 20 2 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 30 40 50 100 200 300 400 10 400 Eccentric distance l (mm) Eccentric distance l (mm) Allowable side load F (N) F Stroke (mm) Bore size (mm) Model 25 50 75 100 125 150 175 200 DMGTM 140 151 162 176 193 212 178 204 63 MGTL 199 212 226 243 170 186 127 143 -X F MGTM 199 213 228 246 267 291 221 250

100 Pressure 0.6 MPa Pressure 0.6 MPa 30 0.5 0.5 80 25 Gripping force (N) External grip Gripping force (N) 0.4 0.4 60 20 0.3 0.3 15 40 0.2 0.2 10 20 0.1 0.1 5 L L 0 20 30 50 60 Gripping point L (mm) 40 70 0 30 40 60 70 Gripping point L (mm) 50 80 90 700 180 Angular Type Air Gripper MHY2/MHW2 Series MHW2-32D MHW2-50D MHW2-20D 300 25 100 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa 250