SMC Corporation of America
Elite Part Number Search
Search Results "VZM551-F01-34B-F"

Series IDF*F refrigerated air dryers are larger units with improved ambient (113°F/45°C) and inlet (140°F/60°C) air temperatures. *** These units are not available for use in the United States or Canada *** 50/60 Hz operation ; Max. inlet air temperature: 140°F (60°C) ; Max. flow at rated conditions: 1,059 scfm (30m³/min (ANR) @50°F (10°C) PDP; Connections: R threads are standard on size

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F)

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F)

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 06 (3/4), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F)

VALVE, MECH VZM 400, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FE, VM BODY PT 1/4, 0.44092 lb

Series AMH is a high precision, micro-mist separator combined with a prefilter. The AMH can separate and eliminate aerosol state oil mist in compressed air and remove carbon or dust of more than 0.01micron. The AMH series is suitable for drying/cleaning pneumatic measurement instruments (air micrometer) and precision parts.Micro mist separator w/prefilter, Modular connection is possible

The VM series offers a wide variety of actuator styles and flow capacity up to 1.0 Cv.Fluid: air, Operating pressure: -100kPa to 1.0MPa, Effective area (Cv): 7mm 2 (0.38), Ambient and fluid temperature: -5 to 60 C (no freezing), Port size (nominal size): Rc(PT) 1/8 (6A), MECH VALVE W/ACTUATORS, VALVE, VM (VFM/VZM) MECHANICAL VALVE, CA, VM BODY PT 1/8NPT (F), .33069 lb

The VM series offers a wide variety of actuator styles and flow capacity up to 1.0 Cv.Fluid: air, Operating pressure: -100kPa to 1.0MPa, Effective area (Cv): 7mm 2 (0.38), Ambient and fluid temperature: -5 to 60 C (no freezing), Port size (nominal size): Rc(PT) 1/8 (6A), MECH VALVE W/ACTUATORS, VALVE, VM (VFM/VZM) MECHANICAL VALVE, CA, VM BODY PT 1/8NPT (F), .29619 lb

The VM series offers a wide variety of actuator styles and flow capacity up to 1.0 Cv.Fluid: air, Operating pressure: -100kPa to 1.0MPa, Effective area (Cv): 7mm 2 (0.38), Ambient and fluid temperature: -5 to 60 C (no freezing), Port size (nominal size): Rc(PT) 1/8 (6A), MECH VALVE W/ACTUATORS, VALVE, VM (VFM/VZM) MECHANICAL VALVE, CA, VM BODY PT 1/8NPT (F), .30864 lb

Please contact us for the latest version.sales@ocaire.com, MECH VALVE W/ACTUATORS, VALVE, VM (VFM/VZM) MECHANICAL VALVE, CA, VM BODY PT 1/8NPT (F), .24250 lb

SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated

SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, CX, IF/PFA 1/8 INCH ALL OTHERS, .85800 lb, ModelMeasured fluidFlow rate measurement rangeSet flow rate rangeRated flow rangeMinimum set unitAccumulated pulse flow rate exchange value (Pulse width: 50 ms)Note 1, 2)Display unitsOperating

SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, CX, IF/PFA 1/8 INCH ALL OTHERS, .88184 lb, ModelMeasured fluidFlow rate measurement rangeSet flow rate rangeRated flow rangeMinimum set unitAccumulated pulse flow rate exchange value (Pulse width: 50 ms)Note 1, 2)Display unitsOperating

SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.  The series is incredibly compact and lightweight compared to existing flow sensors.  The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.  The series is incredibly compact and lightweight compared to existing flow sensors.  The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.  The series is incredibly compact and lightweight compared to existing flow sensors.  The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

The VM series offers a wide variety of actuator styles and flow capacity up to 1.0 Cv.Fluid: air, Operating pressure: -100kPa to 1.0MPa, Effective area (Cv): 7mm 2 (0.38), Ambient and fluid temperature: -5 to 60 C (no freezing), Port size (nominal size): Rc(PT) 1/8 (6A), MECH VALVE W/ACTUATORS, VALVE, VM (VFM/VZM) MECHANICAL VALVE, CA, VM BODY PT 1/8NPT (F), .27485 lb