SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-S32-18-N3T"

When a surge-generating load, such as a relay or solenoid valve, is driven directly, use a product that incorporates a surge absorption element. 18. The power supplies should be separated between the controller power and the I/O signal power, and both power supplies must not be of the inrush-current limited type.

When the servo motor is OFF, SVRE is OFF. *1) 18 *ESTOP ESTOP is ON during normal operation. During activation of Teaching Box stop switch or by the stop command, this terminal is OFF. *2) 19 *ALARM When there are no alarms, this terminal is ON.

Enter "password". 18 - (2) Set the controller so that the communication speed can be changed. Change "Parameter protect" setting so that "Communication speed" parameter can be changed. View the parameters of the controller. (2)-1 Change parameter protect to [3: Common + Extend + Step]. (2)-2 Select Download.

20 Output No. 1 3 5 7 9 11 13 15 24 V Type +COM EX510-S102 Terminal No. 1 3 5 7 9 11 13 15 17 19 Output No. 0 2 4 6 8 10 12 14 0 V Type + + + + + + + + -COM Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 0 V Type + + + + + + + + -COM : Only a flat cable type manifold (P kit) can be connected to EX510-S 02 .

20 Output No. 1 3 5 7 9 11 13 15 24 V Type +COM EX510-S102 Terminal No. 1 3 5 7 9 11 13 15 17 19 Output No. 0 2 4 6 8 10 12 14 0 V Type + + + + + + + + -COM Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 0 V Type + + + + + + + + -COM : Only a flat cable type manifold (P kit) can be connected to EX510-S 02 .

20 Output No. 1 3 5 7 9 11 13 15 24 V Type +COM EX510-S102 Terminal No. 1 3 5 7 9 11 13 15 17 19 Output No. 0 2 4 6 8 10 12 14 0 V Type + + + + + + + + -COM Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 0 V Type + + + + + + + + -COM : Only a flat cable type manifold (P kit) can be connected to EX510-S 02 .

External Wiring Diagram . 18 4.1 CN1: Power supply cable . 18 4.2 CN2: Motor power connector and CN3: Encoder connector . 18 4.3 CN4: Parallel I/O connector . 18 5.

Name Qty 1 Rod cover 1 2 Head cover 1 3 Cylinder tube 1 4 Piston rod 1 5 Piston 1 6 Cushion ring 2 7 Bushing 1 8 Cushion valve 2 9 Tie rod 4 10 Tie rod nut 4 11 Snap ring 2 12 Wear ring 1 13 Rod seal 1 14 Cushion seal 2 15 Piston seal 1 16 Cushion valve seal 2 17 Cylinder tube gasket 2 18 Magnet (1) 30 - Figure-5 180 to 250 Table.14 Parts list No.

Product Outline . 17 3.1 System construction . 17 3.2 Setting Function . 18 3.3 Step data setting method . 21 3.4 Parameter setting method . 27 4. Wiring of cables / Common precautions . 30 5.

MGZ MGT (mm) Bore size (mm) B C DA FA FB FC G GA GB GC H HA HB J K L MM ML NN NL OA Standard stroke (mm) 63 80 100 10 12 15 78 91.5 15 15 20 103 12 18 25 M10 M12 M14 16 22 25 162 202 240 20 25 30 16.5 14.5 18 49 56.5 66 13.5 15.5 19 39 45.5 55.5 77 96.5 116 16.5 19 23 M6 x 1.0 M8 x 1.25 M10 x 1.5 22 26 32 58 54 62 39 46 56 8.6 10.6 12.5 M10 x 1.5 M12 x 1.75 M14 x 2.0 25, 50, 75, 100, 125,

CE2 ML2B ML2B Welding machine Welding machine 18 cm 18 cm 18 cm Operating range Operating range Avoid applications where the cylinder is in direct contact with water and oil, etc. Operating Piping port variation 1. Positioning at cylinder stroke end Stable stop accuraccy at end of stroke positioning is not obtained due to large speed change from cushion influence.

Bore size (mm) Symbol Stroke 10 16 20 10 mm 16 mm 20 mm 8 12 18 Dust cover type Fluororubber (FKM) F Action D Double acting Applicable Auto Switch/Refer to pages 62 to 65 for further information on the auto switch.

Consult with SMC concerning water resistance, elasticity of lead wires, and usage at welding sites. 18 Series CU Specific Product Precautions Be sure to read before handling. Refer to pages 12 through 18 for Safety Instructions, Actuator Precautions, and Auto Switch Precautions. Installation and Removal of Snap Rings Caution Selection Caution 1.

Refer to pages 15-18-3 to 15-18-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 15-8-6 to 15-8-8 for Precautions on every series. 15-12-1 2 Series AQ Construction AQ1500/1510 AQ2000/3000/5000 Component Parts Material/Model No.

L1 L2 A(2) L3 H(1) T2 T1 D1 D2 Model AS1200-M3 M3 x 0.5 M3 x 0.5 4.5 6.6 23.5 21.5 8 5 5 20.5 18.5 AS1200-M5 M5 x 0.8 M5 x 0.8 25.5 8 10 28.3 10.3 9 9 25 22.2 AS1200-U10/32 10-32 UNF 10-32 UNF AS220-01 27.4 32.4 14.6 14.3 14.1 31.4 36.4 18 12 (12.7) 1/8 1/8 AS220-02 29.8 34.8 19.5 18 18 35.8 40.8 27.2 17 (17.5) 1/4 1/4 AS320-03 35.6 40.6 24.3 22.5 20.8 41.9 46.9 30 19 3/8 3/8 AS420-04 42.4

Hysteresis Switch operating position (ON) Switch return position (OFF) Model Hysteresis (mm) MRHQ10 0.5 MRHQ16 0.5 MRHQ20 1.0 MRHQ25 1.0 12-11-18 19 Rotary Gripper Series MRHQ Mounting of Auto Switch Mounting Switches to Verify Rotation Mounting Switches to Verify Opening/Closing of Gripper 1.

Female thread type T D H L L (mm) T Connection female thread H Width across flats Effective area mm D L When connected 38.5 Body size L Min. bore Weight g Model KK3S-01F Rc 1/8 1/8 8.2 22.4 20.6 18.2 36 14 KK4S-02F Rc 1/4 10.9 54.1 54.1 36.6 50.4 1/4 25.4 19 -03F 54.8 43.4 42.7 51.1 Rc 3/8 14.4 KK6S-03F 63.9 91.2 80.9 58.6 1/2 31.2 24 -04F Rc 1/2 18 66.3 85.0 81.6 61 Nut fitting type (for

(26) A B 16 (24) B 20 27.5 27 24.5 31 25.5 27.5 29 27 24 30 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 18 (26) 16 (24) 25 30 29.5 27 31 25.5 27.5 29 27 24 30 22.5 (30.5) 21.5 (29.5) 15.5 (23.5) 18.5 (26.5) 20.5 (28.5) 19 (27) 17 (25) 32 33.5 33 30.5 32 26.5 28.5 30 28 25 31 25 (34) 24 (33) 18 (27) 21 (30) 33 (32) 21.5 (30.5) 19.5 (28.5) 40 38 37.5 35 36.5 31 33 34.5 32.5 29.5

1 26 28 39 79 37 A Width across flats 17 (2 locations) (117) MHC2 30 48 Width across flats 19 (2 locations) MHT2 13 38 38 38 18 MHY2 18 2-M12 X 1.75 (Piston rod screw) Closed E 18 MHW2 60 86 Open F 28 28 MRHQ 4-M12 X 1.75 through Auto switch (Thread for mounting attachment) B C D E F G H 148 206 246 J 252 336 450 Model MHL2-40D MHL2-40D1 MHL2-40D2 72 130 170 348 466 546 116 174 214 288 406