JOG and constant rate movement, return to origin, test operation and testing of compulsory output can be performed. 27 Series LEC Teaching Box/LEC-T1 How to Order LEC T1 3 J G Enable switch (Option) Teaching box Enable switch S None Equipped with enable switch Nil Cable length 3 3 m Interlock switch for jog test function Stop switch Initial language J E Japanese English Stop switch G Equipped
7.3 <> (NPNPNP) LEHS10K3-4 NPN 6 - 4.3 3 8 2 5 1 4 7 6 1 2 3 4 5 6 7 8 ( DC24V) 7 - 5. 5.1 I/O LEC-CN5-* PLC DC24V 2) CN5 1) CN4 LE-CP-*-* () LE-CP-*S-* () CN3 CN2 120.3 120.3 mm mm 200 200 mm/s mm/s 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN1 DC24V 2) USB (A-miniB type ( <> AWG20 (0.5mm 2) (, USB ) LEC-W2 1 2UL ,UL1310 Class2 (3m LEC-T1
JOG and constant rate movement, return to origin, test operation and testing of compulsory output can be performed. 57 Series LEC Teaching Box/LEC-T1 How to Order LEC T1 3 J G Enable switch (Option) Teaching box Enable switch S None Equipped with enable switch Nil Cable length 3 3 m Interlock switch for jog test function Stop switch Initial language J E Japanese English Stop switch G Equipped
ASS Dimensions ASR AS220M-01 02 AS120M ASF H 8 (Hexagon width across flats) L1 T2 24.8 (MAX. 29.8) 28.2 (MAX. 33.2) M5 x 0.8 L2 A L3 D1 9 10.3 10 M5 x 0.8 10-32 UNF D2 T1 9 Dimensions A L2 L3 T1 T2 H L1 D1 D2 Model Min. Min. Max. Max.
Connector block assembly (For 9 to 17 stations (T1) terminal block) t-6 SX5000-64-8A SX3000-64-8A M3 x 30 (Matt nickel plated) SX3000-22-2 (M2 x 24) SX5000-57-6 Round head combination screw y Gasket DIN rail SX3000-57-4 VZ1000-11-1u i Refer to page 1-6-77. Note) The numbers t1 to 4 are for 24 VDC. For 12 VDC, suffix -12V to the parts no.
Tubing extensions size Nut Insert bushing Model Size Insert pin/Name plate symbol LQ1E2A-T 2 2-07 LQ1-2N07 LQ1-2B07 1/4" x 5/32" LQ1E3A-T 3 3-11 LQ1-3N11 LQ1-3B11 3/8" x 1/4" LQ1E4A-T 4 4-13 LQ1-4N13 LQ1-4B13 1/2" x 3/8" LQ1E5A-T 5 5-19 LQ1-5N19 LQ1-5B19 3/4" x 5/8" LQ1E6A-T 6 6-25 LQ1-6N25 LQ1-6B25 1" x 7/8" 5-15 A Tubing Extension Union Tee LQ1T-T T1 type T2 type Metric size C side Part
Max. 3.0A Number ol setting posilions 28 Position setting method Setting with dedicated teaching box (LC5-1-T1-02) Position control method Absolute and incremental moves Speed: 6 to 200mny's (with feed screw lead of 12mm) Input signal capacity Optically isolated input 24VDC Max.
bar absolute, T1 = 297 5K, 0.07 bar P 0.14 bar.
FGH Set of Components for Companion Flange (mm) (mm) FQ1 A B C D T1 Part No. Applicable model Material Flange dimension Applicable model Flange Hexagon bolt Applicable model E F T2 Part No. Gasket Part No.
I/O LEC-CN5-* 1) PLC 1) 2) DC24V CN5 1) LE-C*-*-* LE-C*-*S-* CN4 CN3 CN2 120.3 120.3 mm mm 200 200 mm/s mm/s 100 500 100 500 1 1 200 1000 200 1000 2 2 2) 50 200 50 200 3 3 CN1 DC24V <> AWG20 (0.5mm 2) USB A-miniB type USB LEC-W2 3m LEC-T1-3JG* 1 2 UL ,UL1310 Class2 LEC 5.P.35 USB P.38 6.3 <> NPNPNP LEY16B-100 NPN 4.2 LEC -17- 1 1 2 1 1 DATA TEST DATA
Metric Size L4 Weight (g) AS A2 A1 M L3 L2 L1 d T1 D1 D2 H2 H1 Max.
Connector block assembly (For 9 to 17 stations (T1) terminal block) t-6 SX5000-64-8A SX3000-64-8A M3 x 30 (Matt nickel plated) SX3000-22-2 (M2 x 24) SX5000-57-6 Round head combination screw y Gasket DIN rail SX3000-57-4 VZ1000-11-1u i Refer to page 1-6-77. Note) The numbers t1 to 4 are for 24 VDC. For 12 VDC, suffix -12V to the parts no.
Average suction flow rate V x 60 T1 V x 60 T1 Q = Q = + QL T2 = 3 x T1 T2 = 3 x T1 Q : Average suction flow rate /min (ANR) V : Piping capacity () T1 : Arrival time to stable Pv 63% after adsorption (sec.) T2 : Arrival time to stable Pv 95% after adsorption (sec.) QL : Leakage at work adsorption /min (ANR) 2.
64-1A 1NA -1A:+COM -1NA:-COM 5-2 Connector block assembly (for 26 pins flat cable) SX3000-64-2A-26 2NA SX5000-64-2A-26 2NA Note) For 24 VDC -2A:+COM -2NA:-COM 5-3 Connector block assembly (for 20 pins flat cable) SX3000-64-2A-20 2NA SX5000-64-2A-20 2NA 5-4 Connector block assembly (for 10 pins flat cable) SX3000-64-2A-10 2NA SX5000-64-2A-10 2NA Connector block assembly (for2to8stations(T,T1
[Inrush] Rated voltage [Holding] 1 2 35% (SX090) 42% (SX9 ) of rated voltage 0 V 100 10 ms T1 (ON) (2 s or more) T2 (OFF) Energized condition -8- Dimensions 2-port SX91/Normally closed SX92/Universal 10 Base hole dimension 4.5 0.05 2 x M2 x 0.4 Thread depth: 6 or more 9.8 0.3 7.4 38.1 (Lead wire AWG#26) 300 5 5 10 3.4 +0.05 0 2 x 3 (Port hole dimension) (4.5 0.05) 10.3 8.4 8.3 8.9 C0.2 or
LEC-OM00506 PRODUCT NAME Teaching Box for Electric actuator MODEL / Series/Product Number LEC-T1 Series Applicable models For Series LEC For Series LEC For Series LECPA (TB Ver2.1 or more) Contents Safety Instructions . 6 Changes by teaching box version. . 8 1.
absolute, T1 = 297 5K, 0.07 bar P 0.14 bar.
Interface plate for ZSM Ejector P31806-01 (blank) P31806-02 (use with switch) CD-P11 Contact protection box 0 NZM Ejector Mounting 1 1 8 PT T1 1/8 NPTF S W I T C H T Y P E 15L Solid state (NPN) 21L Contact reed CONTACT PROTECTION BOX/INTERNAL CIRCUIT Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 !