Bore size (Stroke (mm)) 6 8 12 16 20 25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 Applicable Auto Switches/Refer to Best Pneumatics No. 3 for further information on auto switches.
Power supply available all over the world Single-phase 100 VAC, 200 VAC, 230 VAC (50/60 Hz) Air flow capacity (L/min [ANR]) Outlet air temperature adjustment range Outlet air set pressure range Outlet air temperature stability Filter nominal filtration rating Temperature control method Model Port size IDH4 Rc3/8 100 to 500 0.18F (0.1C) 0.01 m (99.9% filtration efficiency) Heater operation
Specifications Applicable model Base mounted type (SYJ314R,SYJ324R) 30inHg~100 (--100kPa to 0.7) 22~100 (0.15 to 0.7) External pilot pressure Main pressure Operating pressure range PSI (MPa) P,R port M5 0.8 A port M5 0.8 X port (External pilot) M5 0.8 Note) Externally piloted body ported valves(SYJ3 2R) can only be used on the manifold. 11 Series SYJ300 3 Port Solenoid Valve Manifold Specifications
Standard Strokes Symbol Rubber bumper Bore size [mm] Standard stroke [mm] 12 (10 x 2) 16 (12 x 2) 10, 20, 30, 50, 100 20 (16 x 2) 25 (20 x 2) 20, 30, 50, 100, 150 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) 25, 50, 100, 150, 200 Intermediate strokes are available as a special order. Refer to pages 10 and 11 for cylinders with auto switches.
CY Graph (1) MG 100 Total operation cycles (10,000) CX 50 D40 30 -X 20 2010 Data 100 200 300 400 500 700 1000 Stroke (mm) Graph (2) 105 Particle concentration (particles/m3) Inner Cover Holding Screw Tightening Torque [Nm] Class M3.5 [Class 100] 104 Tightening torque Model Screw size CYP15 0.3 M3 x 0.5 103 Class M2.5 [Class 10] CYP32 2.45 M6 x 1 102 Plate Class M1.5 [Class 1] 101 Stroke adjustment
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com High precision type (External absorber type) 11-12-2 7 SMC Actuators: Copper-free Air Grippers 6, 10, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125 Cylinder bore size (mm) Air Grippers Series Application 6 10 12 16 20 25 32 40 50 63 80 100 125 Standard Copper-free
In the default settings, the resolution of the 100 L/min type is 1 L/min, and the 10 L/min type is 0.1 L/min. : When a product other than the 10 L/min type and 100 L/min are used, [---] is displayed and this Function Setting is not available. : This function cannot be used when CFM has been selected by the unit selection function, [---] is displayed.
point L (mm) 120 80 160 200 20 40 60 Gripping point L (mm) 80 0 20 40 60 Gripping point L (mm) 80 100 120 MHW2-25D MHW2-40D 160 50 Pressure 0.7 MPa Pressure 0.7 MPa MHZ 140 0.6 0.6 40 120 Gripping force (N) Gripping force (N) 0.5 0.5 MHF 100 30 0.4 0.4 80 0.3 MHL 0.3 0.2 20 60 0.2 40 MHR 10 20 MHK 0 20 40 60 Gripping point L (mm) 100 80 80 100 120 140 160 0 20 40 60 Gripping point L (mm)
) 24 VDC 12 VDC SRP PVQ30 (2.3) SRF 120 ARX20 P = 0.35 MPa 100 P = 0.25 MPa VCHR Flow rate (l/min) 80 P = 0.18 MPa ITV 60 P = 0.1 MPa 40 IC 20 PVQ 0 0 0 20 40 40 80 60 120 80 160 100 200 120 240 140 280 160 320 180 360 200 400 Current (mA) 24 VDC 12 VDC VEF VEP VER PVQ30 (4.0) VEA 120 100 P = 0.12 MPa VY2 Flow rate (l/min) P = 0.08 MPa 80 VBA VBAT P = 0.06 MPa 60 AP100 40 P = 0.04 MPa
Nil 6 50, 100, 150, 200 1 pc.
In the default settings, the resolution of the 100 L/min type is 1 L/min, and the 10 L/min type is 0.1 L/min. : When a product other than the 10 L/min type and 100 L/min are used, [---] is displayed and this Function Setting is not available. : This function cannot be used when CFM has been selected by the unit selection function, [---] is displayed.
Supply pressure: 0.3 to 1.0 MPa Set pressure: 0.2 MPa Flow rate: 0 L/min (ANR) Supply pressure: 0.5 MPa IR1000-01 IR1000-01 IR1000-01 Back pressure: 0.5 MPa 0.5 0.204 0.2 Set pressure P2 (MPa) Set pressure (MPa) Set pressure (MPa) Set pressure (MPa) 0.4 0.202 0.15 Set point 0.3 0.200 0.1 0.2 0.198 0.05 0.1 0.196 0 40 20 80 60 100 140 120 0 50 100 200 250 150 0 0.2 0.1 0.4 0.3 0.6 0.5 0.8
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Max. supply pressure 0.1 to 1.0 MPa Note) Flow conditions VBA1110: IN = OUT = 1.0 MPa, VBA1, VBA22 100 , 42 100: IN = OUT = 0.5 MPa Refer to the flow characteristics table for selection.
Cylinder Speed Chart Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Series Average speed (mm/s) 800 700 600 500 400 300 200 100 0 It is when the cylinder is extending that is meter-out controlled by speed controller which
S n Auto switch Without auto switch (Built-in magnet) Nil Bore size (Stroke (mm)) For the applicable auto switch model, refer to the table below. 8 12 16 20 25 25, 50, 75, 100, 125, 150 50, 75, 100, 125, 150 75, 100, 125, 150, 175, 200 100, 125, 150, 175, 200, 225, 250 100, 125, 150, 175, 200, 225, 250, 275, 300 Option Nil Standard (with urethane bumper) With shock absorbers 2 pcs.
ISA2-G ISA2-H Detection nozzle: 1.5 Detection side piping: 6 x 4 tubing 5 m Supply pressure: 100 kPa Detection nozzle: 2.0 Detection side piping: 6 x 4 tubing 5 m Supply pressure: 100 kPa Detection distance-Response time characteristics Detection distance-Response time characteristics Detection nozzle: 1.5 Detection side piping: 6 x 4 Supply pressure: 100 kPa Set distance: 0.15 mm Detection
SET MODE SD SG RD RS-232C COM S.STOP OUT1OUT2OUT3OUT4OUT5 100 to 240 VAC 1 t 1 10 x 106 100 kHz Counting speed f = = = 10 Hz 7 10 4-4.5 33.5 104 BCD output connector 2) UP/DOWN input Input wave form conditions: At a maximum of 100 kHz, the UP/DOWN wave form should be as shown below. 1130.2 125 +12 V 10% UP pulse +12 V 10% DOWN pulse 5 sec 64 5 sec 59 5 sec 3) 15 mA when BCD is output.
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
to 100 kPa -100 kPa 100 kPa 0 to 1 MPa 0 1 MPa -0.1 MPa For positive pressure 0 to 500 kPa 0 500 kPa -50 kPa -13No.PS-OMG0006-D Dimensions PSE5601 , PSE56N01 02 N02 Be sure to release the air in the air tube of the cable to the atmosphere.
The graphs below show the response time when the workpiece is approached at 90% distance and 0% distance (close contact). (: The switch point is 100% distance) (Example: When the switch point is set to 0.1 mm, the response time when the workpiece is at 0.09 mm and 0.00 mm are measured).