SMC Corporation of America
Elite Part Number Search
Search Results "XLAV-40F-5HZ"

Valve specifications Pilot type Type of actuation Air Fluid Main valve Poppet Maximum operating pressure 0.7MPa Effective area 3mm Maximum vacuum pressure 84kPa Operating pressure 0.25 to 0.6MPa Supply pressure range 0.25 to 0.55MPa 5 to 50C Cv factor 0.17 Operating temperature range Polyethylene sintered body (30m) Electrical entry Plug connector Suction filter Maximum operating frequency 5Hz

XLAV/With solenoid valve J Port P (pressure port) N M K L P R Port R (exhaust port) (mm) M 3 3 3 3 4 4 L 8.5 8.5 8.5 8.5 12 12 K 13 14 23 25 29 39 J 16.5 16.5 17.5 17.5 29 29 N Model XLAV-16 XLAV-25 XLAV-40 XLAV-50 XLAV-63 XLAV-80 3 3 3 3 2 2 Other dimensions are the same as XLA. 7 Series XLC Normally Closed/Bellows Seal Air Operated Type How to Order XLC 16 F9N Switch quantity/Mounting

XLA XLAV/With solenoid valve J XL XL XLQ XM XY M N Port P (Pressure port) Port R (Exhaust port) DXSA K L XVD XGT CYV (mm) (mm) J K L M N J K L M N Model XLAV-16 XLAV-25 XLAV-40 XLAV-50 Model XLAV-63 XLAV-80 XLAV-100 XLAV-160 35.5 12.3 10.2 3.6 3.6 78.5 28.7 12 4 2 40.5 13.8 10.2 3.6 3.6 87 38.7 12 4 2 50.5 21.6 10.2 3.6 3.6 105.5 50.7 12 4 2 57 24.6 10.2 3.6 3.6 128.5 57.7 12 4 2 Other dimensions

IDG60M, IDG100M are fitted with AMH micro mist separator with pre-filter. 1.77 3.53 5.29 Flow Flow Flow 10 25 50 100 200 300 500 600 750 1000 110 170 240 300 100 150 75 50 Single Type 76F (60C) Dew point Single Type 40F (40C) Dew point Single Type 4F (20C) Dew point 3.53 5.29 8.02 11.3 14.12 2.72 5.44 8.29 0.44 1.09 2.19 4.41 8.83 13.24 22.07 25.6 31.78 42.02 Model Inlet Model Inlet Model

XLA XLAV/With solenoid valve J XL XL XLQ XM XY M N Port P (Pressure port) Port R (Exhaust port) DXSA K L XVD XGT CYV (mm) (mm) J K L M N J K L M N Model XLAV-16 XLAV-25 XLAV-40 XLAV-50 Model XLAV-63 XLAV-80 XLAV-100 XLAV-160 35.5 12.3 10.2 3.6 3.6 78.5 28.7 12 4 2 40.5 13.8 10.2 3.6 3.6 87 38.7 12 4 2 50.5 21.6 10.2 3.6 3.6 105.5 50.7 12 4 2 57 24.6 10.2 3.6 3.6 128.5 57.7 12 4 2 Other dimensions

Recommended Valve PA3000 PA5000 VQZ140 (exhaust center) VQZ240 (exhaust center) Refer to page 21 for further details. 6 Series PA3000/5000 Performance Curves/Air Operated Type PA513 Flow rate characteristics PA313 Flow rate characteristics 50 50 Cycle 7Hz Cycle 5Hz Cycle 3Hz (no change when SUP=0.2, 0.3MPa) Cycle 7Hz Cycle 5Hz Cycle 3Hz (no change when SUP=0.2MPa) SUP=0.5MPa 40 40 SUP=0.5MPa

Internal pilot: 1 to 5HZ and external pilot: 1 to 8Hz is reference. The charts on page 10 show the relation for the adjustment needle value and operation frequency. However, there is approx. 2Hz of variation depending on individuality. Operating conditions affect the operating frequency.

Look up from the 5Hz switching cycle to find the intersection with SUP=0.35MPa. 2. From the point just found, draw a line to the Y-axis to find the air consumption. The result is approximately 9l/min (ANR). 1 0 2 3 4 5 6 7 8 9 10 Cycle (Hz) Caution 1. These flow rate characteristics are for fresh water (viscosity 1mPas, specific gravity 1.0). 2.

Discharge capability 1) Flow-rate characteristics PB1313A Flow-rate characteristics (5Hz) PB1313A5Hz 0.5 SUP=0.5MPa Discharge pressure (MPa) 0.4 SUP=0.4MPa MPa 0.3 SUP=0.3MPa 0.2 SUP=0.2MPa 0.1 0 0 200 400 600 800 1000 Discharge rate (mL/min) mL/min Caution -The above flow characteristic graph is for clean water (viscosity 1mPas, specific gravity 1.0).

Type of valve actuation Air Fluid 0.2 to 0.5MPa Operating pressure range Internal pilot type 5 to 50C Ambient and fluid temperature 25ms or less Response time (for 0.5MPa) Note 1) 5Hz Maximum operating frequency Non-locking push type, Slotted locking type Manual operation With vacuum pressure gauge Pilot valve individual exhaust type, Main valve/Pilot valve common exhaust Pilot exhaust type

Recommended Valve PA3000 PA5000 VQZ140 (exhaust center) VQZ240 (exhaust center) Refer to page 21 for further details. 6 Series PA3000/5000 Performance Curves/Air Operated Type PA513 Flow rate characteristics PA313 Flow rate characteristics 50 50 Cycle 7Hz Cycle 5Hz Cycle 3Hz (no change when SUP=0.2, 0.3MPa) Cycle 7Hz Cycle 5Hz Cycle 3Hz (no change when SUP=0.2MPa) SUP=0.5MPa 40 40 SUP=0.5MPa

Operating Pressure Air 145psi (1.0MPa) Size At 75F (24C) At 200F (93C) 3/8 1/4 1/2 5/32 5/8 3/4 1400psi 1200psi 950psi 1200psi 900psi 800psi Proof Pressure 450psi (3.1MPa) Recommended Fluid and Ambient Temperature* -40F to 140F (-40C to 60C) 7 Ncm/min. or less Leak Rate at -40F (-40C) Thread Portion Nut ANSI/ASME B1.20.1, 1983, R1992 Thread JIS B 0208 (Unified fine thread), ISO 263 Thread

Discharge capability 1) Flow-rate characteristics PB1013A Flow-rate characteristics (5Hz) PB1013A flow-rate characteristics (When operated at PB1013A5Hz 5H ) 0.7 Discharge pressure (MPa) 0.6 SUP=0.7MPa 0.5 MPa SUP=0.5MPa 0.4 SUP=0.35MPa 0.3 SUP=0.2MPa 0.2 0.1 0 0 200 400 600 800 1000 Discharge rate (mL/min) mL/min Caution The above flow characteristic graph is for clean water (viscosity

Fluid Air Operating pressure range Internal pilot type 0.2 to 0.5MPa (29 to 72 psi) 5 to 50C (41 to 122F) Ambient and fluid temperature Response time (for 0.5MPa) Note 1) 25ms or less Maximum operating frequency 5Hz Manual operation Non-locking push type, Slotted locking type With vacuum pressure gauge Pilot valve individual exhaust type, Main valve/Pilot valve common exhaust Pilot exhaust

: 86F (30C) 500 1000 Ambient temperature: 59F (15C) 400 800 Ambient temperature: 59F (15C) 300 600 200 400 100 200 0 0 0 0 10C 20 30 40 50 60 70 40F 60 80 90 110 130 150 10C 20 30 40 50 60 70 40F 60 80 90 110 130 150 Circulating fluid temperature Circulating fluid temperature Pump Capacity (Thermo-con Outlet) The pressure on the y-axis shows the discharge pressure of circulating fluid in

Standard Specifications Standard Specifications Type of seal Metal seal Rubber seal Fluid Air, Inert gas Air, Inert gas Max. operating pressure 100 psi (0.7MPa) High pressure type 113 psi (0.8MPa) Min. operating pressure 14 psi (0.1MPa) 21 psi (0.15MPa) Valve specifications Solenoid specifications Note 1) Note 1) Ambient and fluid temperature 14 to 122F 14 to 122F Max. operating frequency 20Hz 5Hz

SMC endurance test conditions Normal temperature (Room temperature) 5Hz Rated voltage Max. operating pressure The valve was opened and closed, checked for internal and external leakage and proper operation. We confirmed that the product satisfies the product specifications up to 2,000,000 cycles. 16 XSA-OMS0001-A 7. Troubleshooting This section summarizes troubleshooting the product.

The ionizer generates ion at the preset frequency. 0: 1Hz 1: 3Hz 2: 5Hz 3: 10H 4: 15Hz 5: 20Hz 6: 30Hz 7: 60Hz Operation with pulse + Ion Ion (e.g.) Charged workpiece: Charged in negative Static neutralization is completed (6) Wiring of Power supply cable Connect the special power supply cable to the unit.

ZSE1-00ZSM1-0 Vacuum pressure switch 30 m PE (Polyethylene) Suction filter Valve Specifications How to operate Pilot type NBR poppet 3 mm2 Compact and lightweight 15.5 mm width, 400 g (full system) Main valve Effective area Cv factor Operating pressure range Electrical entry Max. operating frequency Voltage Power consumption 0.17 0.25 to 0.7 MPa Plug connector, Grommet (available on DC) 5Hz

No 0-1Hz 1-3Hz 2-5Hz 3-8Hz 4-10Hz 5-15Hz 6-22Hz 7-33Hz 8-5 6 7 ; < = : 9 8 Generate only plus ion 9-Generate only minus ion 6. Selection and setting of equipment 6-1. Sensing DC mode 1. selection of bar length Select the length applicable to work size base on [2. static charge elimination area of 7-1. static charge elimination characteristics (reference)] 2.