SMC Corporation of America
Elite Part Number Search
Search Results "TIHA05R-16"

The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation SS5V4 MANIFOLD SV4000. TIE ROD. VALVE. SS5V4 NO SIZE RATING. 0.242 lb. 21.

PVQ series, compact proportional solenoid valve, was designed by SMC with a direct poppet construction. ?This construction?enables low leakage, while de-energized.? PVQ series has been used in applications such as air blow, flow control, hand piece control for dental unit and other respiratory equipment,?as well as, cooling for laser machinery etc. Direct operated poppet valve construction

PVQ series, compact proportional solenoid valve, was designed by SMC with a direct poppet construction. This construction enables low leakage, while de-energized. PVQ series has been used in applications such as air blow, flow control, hand piece control for dental unit and other respiratory equipment, as well as, cooling for laser machinery etc. Direct operated poppet valve construction

This is a legacy product. Please contact us for the latest version.sales@ocaire.com PVQ PROPORTIONAL VALVE. PROPORTIONAL VALVE. VALVE. PVQ NO SIZE RATING. .21067 lb. 2H.

PVQ series, compact proportional solenoid valve, was designed by SMC with a direct poppet construction. This construction enables low leakage, while de-energized. PVQ series has been used in applications such as air blow, flow control, hand piece control for dental unit and other respiratory equipment, as well as, cooling for laser machinery etc. Direct operated poppet valve construction

Lightweight, compact, and precision control make these speed controls the right choice for many heavy-duty applications. These speed controls are offered with in-line and elbow construction to give the widest choice to your unique application. Locking nuts are included as standard as well as simplified mounting. Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric

With the release of the KN series nozzles and gauge heads 30~90% of air consumption required for the current nozzle operation can be saved with the appropriate selection of the new nozzle and sizing. Many variations of nozzle are available with tube materials including nylon, soft nylon, soft copper pipe and OST tubing. Sizes range from 4mm-20mm.Nozzle for One-touch fittings, 4 connection

16 16 16 17 17 17 17 21 21 21 21 21 21.8 21.8 21.8 22 22 22 25 17 16 16 16 21 17 17 17 17 17 21 21 21 16.8 20.4 20.4 2 22 22 25 1.6 1.6 1.6 1.6 3.5 3.5 3.5 3.5 3.5 3.5 5.4 5.4 5.4 4.6 7.0 7.0 8.5 8.5 8.5 9.8 23 15 16 23 40 16 23 37 40 53 36 44 68 76 64 76 43 51 76 126 100/400 100/400 100/400 100/400 100/200 100/400 100/400 100/400 100/200 100/200 100/200 100/200 100/100 100/100 100/100 100

(mm) 10 10 A8 M8 x 1 10 to 16 13 13 A10 M10 x 1 20 to 32 16 16 A14 M14 x 1 40, 50 20 20 25 25 Vacuum entry 32 32 40 B5 40 M5 x 0.8 50 50 Pad material N NBR Pad type S Silicon rubber F Ball joint U Urethane rubber F Fluoro rubber GN Conductive NBR GS Conductive silicon rubber 20 and larger are manufactured upon receipt of order.

Flow Direction Symbols on Body Flow Rate and Sonic Conductance Meter-out type Meter-in type Indication symbol Symbol AS221F-01 AS231F-01 AS221F-02 AS231F-02 AS321F AS331F AS421F AS431F AS121F AS131F Model Metric size 3.2, 4, 6 3.2, 4 6, 8, 10 8, 10 4 6 6 8 10 12 10, 12 Tubing O.D. 1/8", 5/32" 1/8", 3/16", 1/4", 1/4", 5/16", 3/8" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 5/32" 5/16" 3/8"

12.5 14 4.5 98 M5 x 0.8 8.5 70 50 4.6 11 60 NY M4 x 12 3.6 M4 x 12 2.7 M8 x 16 12.5 14 4.5 98 M4 x 0.7 8 70 50 4.6 11 60 NW M4 x 12 3.6 M4 x 12 2.7 M8 x 16 12.5 9 4.5 98 M5 x 0.8 8.5 70 50 4.6 11 60 NT M4 x 12 3.6 M4 x 12 2.7 M8 x 16 12.5 12 8 98 M5 x 0.8 8.5 70 50 4.6 14.5 60 Included Parts List Motor Mounting Diagram Size: 63 Return box Mounting procedure 1) Fix the motor (provided by

, 20 25, 32, 40 50, 63, 80 100 6, 10 15, 20 25, 32 12, 16, 20 25, 32, 40 50, 63, 80 100 10, 16 20 25, 32 12, 16 20, 25 32, 40 32, 40 50, 63 80, 100 6, 10 16, 20 25, 32 20, 25 32, 40 50, 63 12, 16 20, 25 6, 10 16 20, 25, 32 40, 50 10, 15 25 6, 10 16 20, 25 32, 45 Bore size (mm) 5 to 50mm/s 7 to 50 mm/s 5 to 50 mm/s 5 to 50mm/s Piston speed Rubber bumper (basic cylinder section) Shock absorber

B 16 44 8 (2.4) SMC SOL. A 2 () (+) Brown None Connector DB-25SF-N manufactured by Japan Aviation Electronics Industry, Ltd. Station 2 SOL. B 15 () (+) Pink Black SOL. A 3 () (+) Red None 55 Station 3 SOL. B 16 () (+) Blue White Socket side SOL. A 1425 4 () (+) Orange None Station 4 SOL. B Terminal no. 17 () (+) Purple None 5 () (+) Yellow None SOL. A Station 5 SOL.

16 26 QW 46 60 72 RR1 18.9 22.0 RR2 17.9 24.0 SS 5.1 4.0 9.0 TT 15.5 21.0 26.0 UU 16 16 21 VV 16 19 23 W 122 144 160 WW 11 13 20 YW 070 088 104 Z 240 300 360 ZZ XX 38 48 54 Bore size (mm) 25 32 40 Rc1/8 Rc1/16 Rc1/8 Rc1/16 Rc1/4 25.50 29 .0 Rc1/8 Hole Size for Centralized Piping on the Bottom (Mounting side should be machined to these dimensions.)

(Example -EP) 16 Vacuum Pump System Vacuum Unit ZK2mA Series Manifold Refer to page 16 for the vacuum pump system for the manifold.

Pad dia. 10 13 16 20 25 32 40 50 Buffer stroke 10 mm 20 mm 30 mm 40 mm 50 mm Inclination 15 (Rotation 30 ) 708 Vacuum Pad: Ball Joint Type Vertical Vacuum Entry Without Buffer/Male Thread ZPT Series How to Order ZPT 25 F GN B5 A8 Mounting Pad diameter Symbol Mounting Pad dia. 10 10 A8 M8 x 1 10 to 16 13 13 A10 M10 x 1 20 to 32 16 16 A14 M14 x 1 40, 50 20 20 25 25 Vacuum entry port 32 32 40

Auto Switch Proper Mounting Position for Stroke End Detection MY1CW 16, 20 MY1MW 16, 20 B A Reed switch D-A90(V), D-A93(V), D-A96(V) Solid state switch D-F9N(V), D-F9P(V), D-F9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) Mounting position 16 20 20 16 20 Mounting position Mounting position 16 A 70 90 93 73 94 A A 74 B 90 110 107 87 106 B B 86 Operating range Note) 11 7.5 6.5 8.5 6.5 Operating range