SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-32-03-M5T"

When demanding 32-bit data, specifying the lower 16-bit code No. and turning RYn8 to ON sets the lower 16-bit data to RWwn 5 and the upper 16-bit data to RWrn 6. Data is stored in the RXn8. RXn8 turns on at the same time.

DXT170-176-2-01 DXT170-176-2-02 DXT170-176-2-03 DXT170-176-2-04 DXT170-176-2-07 DXT170-176-3-51 DXT170-176-3-06 DXT170-176-3-05 DXT170-176-3-53 For Series VZ300/500 With light/surge voltage suppressor With surge voltage suppressor 100 VAC 200 VAC 110 VAC 220 VAC 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC S E For VZ120 Indicator light is not available for grommet type.

Bore size (mm) D-A3/A4/K3/G3 D-A5/A6/F5/J5 D-Z/Y D-P5DWL 32 BMB2-032 40 BMB2-040 63 BMB1-063 50 BMB1-050 80 BMB1-080 100 BMB1-100 BT-03 BMB4-032 BMB3T-040 BT-05 BMB4-050 BMB3T-050 BT-06 BMB4-063 BMB3T-080 6-12-2 Series C95 Specifications Bore size (mm) 32 40 63 100 50 80 Action Double acting Fluid Air 1.5 MPa Proof pressure 1.0 MPa Max. operating pressure 0.05 MPa Min. operating pressure

The models VX31/32/33 have been revised. For details, please refer to catalog no. ES70-26A. Similar updating for other VX series are scheduled to follow shortly. Series VX Solenoid Coil Assembly How to Order VX021 C 001 01 B Rated voltage (1) VX solenoid coil assembly 02 =+4 7> 01 =+4 7> Electrical option Application 03 =+4 7> Nil # 04 =+4 7> S 5 % * ,* -> -/& 05 ( !

28 49 35 28 16.8 2.7 12 PF3W511 3/41 124 92 46 62.6 57.6 23 41 42 63 48 28 18 3.5 14 S T U V W WX Y Z PF3W504 24 22 32 40 50 4.5 5 1.5 PF3W520 28 22 32 40 50 4.5 5 1.5 PF3W540 34 30 42 48 58 4.5 5 1.5 PF3W511 44 36 48 58 70 5.5 7 2 -41No.PF-OMN0009CN-F PF3W521 2X A AA B DD E F G H J K L N P 11/4,11/2 104 74 31 52 39.5 G 11/4 108 76 33 54 41.5 PF3W521 56 76.6 71.6 28.5 54 25 27.5 3.5 14

EX260-SPN1/2: SI unit with 32 outputs, EX260-SPN1 or EX260-SPN2 This SI unit can be used with both firmware version 1.0.0 and 2.1.1 1, but the MRP function is not available. EX260-SPN1/2 MRP: SI unit with 32 outputs and MRP function, EX260-SPN1 or EX260-SPN2 This SI unit can be used with firmware version 2.1.1 1. This SI unit cannot be used with firmware version 1.0.0.

Manifold solenoid valve: 32 stations (512 point) max. Maintenance and inspection are easy. With control unit Plug-in type/Non plug-in type Filter, regulation valve, pressure switch and air release valve all combine to form one unit. Piping processes are eliminated.

Metric size Inch size P . 15-11-3 3.2 With One-touch fittings 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" Use 1/8" tube. 23 04 06 08 10 12 01 03 05 07 09 11 13 4 6 8 10 12 Flow Direction Symbols on Body JIS Symbol Symbol 15-9-10

. -7No.EX-OMP0013-E Model Indication and How to Order EX260-SEN 1 Connector type, output specification 1 M12 connector, 32 outputs, PNP (negative common) / source 2 M12 connector, 32 outputs, NPN (positive common) / sink 3 M12 connector, 16 outputs, PNP (negative common) / source 4 M12 connector, 16 outputs, NPN (positive common) / sink Fieldbus EN EtherNet/IPTM -8No.EX-OMP0013-E Summary

Note 2) Symbols for inch sizes are as follows: N3: 5/32" N7: 1/4" N9: 5/16" NM: Mixed The top ported elbow is LN and the bottom ported elbow is BN. Kit designation/Electrical entry/Cable length (Refer to page 2-2-16 for detailed information on kits.) SI unit COM. Input block COM.

AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 Valve Mounting VS After confirming the gasket is correctly placed under the valve, tighten the mounting screws with the appropriate torque listed below.

Mounting bracket Minimum order quantity Bore size [mm] Contents 20 25 32 40 Mounting nut (M5, Rc1/8, NPT1/8) 1 1 JSN-020B JSN-032B JSN-040B 1 mounting nut Rod end nut 1 NT-02 NT-03 NT-04 1 rod end nut Refer to page 10 for dimensions. 1 Can be used for M and MZ only.

UNF 0.625 0.75 1.12 0.38 0.88 0.34 0.62 0.81 0.12 1.00 1/8 1.00 0.093 0.22 1/4-28 10-32 UNF 1/4-20 0.250 106 (1 1/16") 10-32 UNF 0.750 0.75 1.47 0.62 1.22 0.47 0.81 0.24 1.12 1.25 1/8 1.25 0.093 0.25 3/16-24 10-32 UNF 1/4-20 0.312 150 (1 1/2") 1/4-20 NUC 1.00 1.25 1.93 0.88 1.57 0.38 1.12 1.56 0.25 1.75 1/4 1.75 0.125 0.38 7/16-20 1/4-20 NUC 5/16-18 0.437 Block Mounting Type (in) ZB2 ZB3

Symbol Data type Data length Bit [byte] Description (IO-Link standard) U8 8 [1] UIntegerT Unsigned integer U16 16 [2] S16 IntegerT 16 [2] Signed integer F32 Float32T 32 [4] Floating point number C32 StringT 32 [4] String 3: "Y" indicates that the parameter setting data is saved to the master, and "N" indicates that the parameter is not saved. 4: Read/write to un-selectable items will be rejected

. -7No.EX-OMN0011-F Model Indication and How to Order EX260-SEC 1 Connector type, output specification 1 M12 connector, 32 outputs, PNP (negative common) / source 2 M12 connector, 32 outputs, NPN (positive common) / sink 3 M12 connector, 16 outputs, PNP (negative common) / source 4 M12 connector, 16 outputs, NPN (positive common) / sink Fieldbus EC EtherCAT -8No.EX-OMN0011-F Summary of Product

M5 x 0.8 1(P) port M5 x 0.8 3(R) port R 3 P 1 10.7 9 M5 X 0.8 external pilot port 32 (Only external pilot type (R)) For the One-touch fittings for P/R port and silencer model no., refer to page 4-14-3.

OUT(2) 1 Thread type Rc NPT G Nil N F IN(1) Voltage 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Port size Class 3 Port size 1/8 (6A) 1/4 (8A) Class 2 Class 4 Symbol 01 02 03 04 06 3/8 (10A) 1/2 (15A) Class B in AC has a rectifying circuit built-in. Class H is AC only. No rectifying circuit.

Thread type AS-D Port size Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT M5 U10/32 01 02 M5 x 0.8 AS-T 10-32 UNF 1/8 N ASP 1/4 ASN Made to Order AQ ASV Grease-free (Seal: Fluorine Coated) + Throttle Valve (Without Check Valve) X21 Lubricant: Vaseline X12 AK Ex.) AS1201FM-M5-23-X12 Ex.)

Bit BYTE 64 (Maximum) Value The Bits 49 54 56 32 30 33 30 2D 49 4C 32 42 4E (hexadecimal number) indicate "ITV2030-IL2BN." (ASCII code) 20 - Setting using buttons ! Caution If the incorrect key is pressed or incorrect information is displayed during setting, power must be shut off and the procedure started again.

B C D H SNKJ-016B SNLJ-016B SN-020B SN-032B NTJ-010A NTJ-015A NT-02 NT-03 19.6 M12 x 1 4 8.1 M4 x 0.7 3.2 6, 10 17 6, 10 7 21.9 M14 x 1 5 9.2 M5 x 0.8 4 16 19 16 8 30 M20 x 1.5 8 15 M8 x 1.25 5 20 26 20 13 37 M26 x 1.5 8 19.6 M10 x 1.25 6 25 32 25 17 T-bracket 4-TC TH 7 +0.2 0 TU -0.1 -0.3 TN TK TX TV 12 TD H10 TT TY TW Part no.