View A PE L1 L2 L3 power supply cable Fig. 3-9 Wiring of power supply cable * Connect an over current protection to the power cable connected to the equipment to avoid hazard. 3.3 Installation HRL Series 3-16 HRX-OM-W060 Chapter 3 Transport and Setting Up 3.3.4 Contact input/output communicatin wiring Be sure to lock out and tag out the breaker of the facility power supply (the users machine
. = 1 m3at a standard absolute pressure ot 101325 Pa is compressed at constanl temperature to a volume V = 0.5 m" then: = P",V" P"=# i.e. p"= u p,.v., to1325m.i.n3 202650 Pa o3n3 The ratio V1^r'2 is the "Compression Ratio" cr with a gauge pressure of 4 bar, { = aill=l3 = a.gs ' \2 1013 The table below shows the pressure ratio for pressures from 1 to 10 barabs. p 1 2 3 4 5 6 7 8 1 0 cr 0.987
. = 1 m3at a standard absolute pressure ot 101325 Pa is compressed at constanl temperature to a volume V = 0.5 m" then: = P",V" P"=# p,.v., i.e. p"= u to1325m.i.n3 202650 Pa o3n3 The ratio V1^r'2 is the "Compression Ratio" cr with a gauge pressure of 4 bar, { = aill=l3 = a.gs ' \2 1013 The table below shows the pressure ratio for pressures from 1 to 10 barabs. p 1 2 3 4 5 6 7 8 1 0 cr 0.987
Double acting, Single rod Double acting, Double rod (-XC2) Double acting, Double rod (-XC2A) L + Stroke L L2 + Stroke L L Rod end female thread Rod end female thread Rod end female thread L1 + Stroke L1 L3 + Stroke L1 L1 Rod end male thread Rod end male thread Rod end male thread Dimensions Dimensions (mm) (mm) Applicable series Dimensions Applicable series Dimensions Bore size (mm) Bore
Option B, option S and HRSH090--40L1 L2 L3 PE Cable tie holder Note: Hold the power supply cable by cable band. (Cable band is prepared by the user.) Fig. 3-11 Wiring of power supply cable HRSH Series 3.3Installation 3-15 HRX-OM-R026 Chapter 3 Transport and Setting Up 5. Mount the power supply terminal cover using 4 screws.
Center/Pressure Center [ ]: AC 3 4 5 G H 01 02 Grommet (G), (H): 10-SYJ7 4322 12 G: Approx. 300 H: Approx. 600 (Lead wire length) 122 [126.4] 36 [38.2] 2 x 4.3 (For mounting) B A 27 A B R1 R2 P Manual override 8.5 34 63.8 13.8 (Light/surge voltage suppressor) 1/4, 1/8 (P, A, B port) 57.5 [64.5] + 42.1 25.5 20 12 22 22 11.5 18 1/4 (R1, R2 port) 31.5 34 63 L plug connector (L): 10-SYJ7 43-L3
View A L1 L2 L3 PE Inlet of the power supply cable Mount for cable tie Note: Prepare a cable tie. Fasten the power cable to the mount on the base with the cable tie.
In case of option B [For Earth leakage breaker], HRS090--40/46L1 L2 L3 PE Cable tie holder Note: Hold the power supply cable by cable band. (Cable band is prepared by the user.) Fig. 3-11 Wiring of power supply cable HRS090 Series 3.3Installation 3-17 HRX-OMT002 Chapter 3 Transport and Setting Up Mount the power supply terminal cover using 4 screws.
View A L1 L2 L3 PE Inlet of the power supply cable Note: Prepare a cable tie. Fasten the power cable to the mount on the base with the cable tie.
119.2 58 71 218 D I M E N S I O N S S I N G L E R O D C L E V I S D I M E N S I O N S A C C E S S O R I E S P I S T O N R O D B A L L J O I N T DIN 648 Part no Applicable bore (mm) A A1 E1 L1 MM RR1 U1 NDH10 NX I-G02 20 34 8.5 16 25 M8x1.25 10.3 11.5 8 +0.058 0 8 -0.2 -0.4 I-G03 25, 32 41 10.5 20 30 M10x1.25 12.8 14 10 +0.058 0 10 -0.2 -0.4 Bore size Model Thread d3 dH7 h d6 b3 b1 l d7 0 l3