plug connector, With light /surge voltage suppressor MZ B 1 100 VAC, 50/60 Hz FZ Plug-in With light/surge voltage suppressor 2 200 VAC, 50/60 Hz Option K Note) K plug connector DIN terminal 3 110 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC FS Plug-in With surge voltage suppressor D DIN terminal/With light /surge voltage suppressor KZ K plug connector With light/surge voltage suppressor DZ
D -DIN terminal DS -DIN terminal with surge voltage suppressor DL -DIN terminal with light DZ -DIN terminal with surge voltage suppressor and light DO-For DIN terminal (without connector) Connector Refer to the Table (1) for the available combinations between each electrical option and rated voltage.
CD-MU02 CD-MU03 CD-MU04 CD-MU05 DZ 8 10 10 14 CZ 8 10 10 14 DY 9 11 13 16 CX 9 11 13 16 DX 18 22 26 32 CT 9.5 11 14 17 DT 9.5 11 14 17 CR 5.3 6.4 8.4 10.5 DR 5.3 6.4 8.4 10.5 CL 26 42 54 64 DL 26 42 54 64 Part no. MU-C02 MU-C03 MU-C04 MU-C05 Part no.
> (There is no S option since a rectifier prevents surge voltage generation.) (14.5) L Grommet, L/M Plug Connector (~) With light (Z) LED Varistor Coil (~) DIN Terminal How to Order Enter the part number for a plug connector solenoid valve without connector together with the part number for a connector assembly with cover. (~) With light (DZ) NL Varistor Coil (~) NL: Neon light
G -Grommet GS-With grommet surge voltage suppressor C-Conduit G-Grommet C-Conduit T -With conduit terminal TS -With conduit terminal and surge voltage suppressor TL -With conduit terminal and light TZ -With conduit terminal, surge voltage suppressor and light D -DIN DS -DIN with surge voltage suppressor DL -DIN with light DZ -DIN with surge voltage suppressor and light DO-For DIN (without
Find the intersection if the speed if 15m/min. on the horizontal axis and the mass of 60kg on the vertical axis in graph, and select RSQ40-DZ that falls in the cylinder operating range. 6-2 Precautions on Selection Use for stopping the pallet on the conveyor. For stopping the load directly mounted to the cylinder, the cylinder pushing force acts as lateral load.
For DZ, the length is longer by 17 mm.
voltage suppressor Q CE-compliant Nil 4 5 6 Electrical entry: D/DL/DS/DZ only 7 9 Made to Order (Refer to pages 1501 to 1503 for details.)
) Light/surge voltage suppressor (DZ) 1 ( ) 1 () (+) Varistor Coil NL Varistor Coil 2 ( ) 2 (+) () Built in the connector Built in the connector M12 connector (Non-polar) M12 connector Surge voltage suppressor (WS/VS) Surge voltage suppressor (WS/VS) (Ground) 3 () (+) 3 ( ) 2 1 Varistor Coil Varistor Coil 3 4 4 ( ) 4 (+) () 4-pin type Light/surge voltage suppressor (WZ/VZ) Light/surge voltage
CRB2BW15/20/30/40-=DZ CRB2BW10-<DZ For 90o For 100o For 90o (Viewed from the long shaft side) For 100o (Viewed from the long shaft side) (Viewed from the long shaft side) (Viewed from the long shaft side) t t y y !3 !3 !3 !3 !3 !3 !3 !3 y r r y A port B port A port B port A port B port A port B port (Long shaft side) e i (Long shaft side) !
DIN Terminal With light/surge voltage suppressor (DZ, YZ) DIN terminal has no polarity M12 Connector With light/surge voltage suppressor (WOZ) Connect correctly the lead wires to + (positive) and (negative) indications on the connector.
CD-MU02 CD-MU03 CD-MU04 CD-MU05 DZ 8 10 10 14 CZ 8 10 10 14 DY 9 11 13 16 CX 9 11 13 16 DX 18 22 26 32 CT 9.5 11 14 17 DT 9.5 11 14 17 CR 5.3 6.4 8.4 10.5 DR 5.3 6.4 8.4 10.5 CL 26 42 54 64 DL 26 42 54 64 Part no. MU-C02 MU-C03 MU-C04 MU-C05 Part no.
Dec Z yZ ZZ AZ BZ CZ DZ . 400 400 This manual provides the following symbols in addition to Danger, 300 300 This unit does not use parts that meet the SCCR specifications.
For Grommet B port (CYL. 1 port) A port (CYL. 2 port) EZ, TZ, DZ, LZ, MZ (24 VDC or less) Plug Note) W/surge voltage suppressor is available only for grommet type. Type of actuation N.C. N.O.
3 position closed center VS4 2.4 2.4 VQ7 (Option) 24 VAC, 50/60 Hz 48 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 6 VDC 12 VDC 48 VDC VZS2000 Rc 1 8 Grommet (G) 3 position exhaust center EVS Single Double 3 position (Closed center) With light/surge voltage suppressor Page 3-7-7 VFN L plug connector (L) L plug connector (LZ) M plug connector (MZ) K plug connector (KZ) DIN terminal (DZ
This manual provides the following symbols in addition to Danger, *Heating capacity increase approx. 10W when high pressure pump option selected Dec Z AZ BZ CZ DZ EZ FZ . This unit does not use parts that meet the SCCR specifications.
Methyl Chloride SF6 CH3Cl Disilane Methyl Fluoride Si2H6 CH3F Silicon Tetrachloride Methanol SiCl4 CH3OH Silicon Tetrafluoride Methylsilane SiF4 CH3SiH3 Dichlorosilane Halocarbon 21 SiH2Cl2 CHCl2F Silane Chlorine SiH4 Cl2 Trichlorosilane Chlorine Trifluoride SiHCl3 ClF3 Sulfur Dioxide Carbon Monoxide SO2 CO Diethyltelluride Germane Te(C2H5)2 GeH4 Tungsten Hexafluoride Hydrogen Sulfide WF6 H2S