SMC Corporation of America
Elite Part Number Search
Search Results "CDVM5KB20F-25-35LZ-M9PAM-C"

Option J: With drain guide Bracket (Option) female thread T: With element service indicator Maintenance space Drain Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35

No.EX-OMS0026CN TMSI EtherNet/IP // EX600-SEN3/4 EX600-ED# 2 8 9 10 12 12 14 SI 15 15 16 16 17 LED 21 25 25 26 27 27 28 28 29 29 29 31 32 42 42 58 62 63 64 EDS 64 TM 64 Logix Designer Device Level Ring (DLR) 69 TM 69 QuickConnect TM 71 EtherNet/IP Web 77 86 -1No.EX-OMS0026CN 1) (ISO/IEC)(JIS) 2) *1) ISO 4414: Pneumatic fluid power -General rules relating

SPEEDCON connector wiring method is explained below. (1) Align the mark B on the metal bracket of the cable side connector (plug/socket) with the mark A. (2) Align the mark C on the unit and insert the connector into the unit vertically.

Port size Flow characteristics Internal pilot type External pilot type 1(P)4(A) 3(R2)2(B) Body port [dm3/(sbar)] B Cv C C [dm3/(sbar)] B Cv 1/2 12 0.14 2.9 14 0.18 3.4 This is the flow rate when the main valve is fully open. 3. How to order Switching type -5 - 4.

Bore Size (mm) 25 32 40 50 63 80 100 Limited warranty and Disclaimer Warning Stroke (mm) 1) The warranty period of the product is 1 year in service or 1.5 years after the product is delivered, whichever is first(1). Also, the product may have specified durability, running distance or replacement parts.

Cross-recessed and flat head machine screw Tightening torque M(D)HR3-10 0.2Nm M(D)HR3-15 0.3Nm Anaerobic adhesive Cover Cover Guide holder B (Cover thickness) C (screw depth) A (Screw size) D (Counterbore) E (P.C.D.)

SPEEDCON connector wiring method is explained below. (1) Align the mark B on the metal bracket of the cable side connector (plug/socket) with the mark A. (2) Align the mark C on the unit and insert the connector into the unit vertically.

Mini Rotary Actuator MODEL / Series / Product Number CRJ*05,1 Contents Safety Instructions 2 17 Outline Specifications 17 18 Mass 18 Effective torque 19 Internal construction and parts CRJB051 19 CRJU051 20 Basic circuit 21 21 Circuit structure Mounting 22 22 Load restrictions Operation of shaft couplings 22 23 Rotating Direction and Rotating Angle 24 Using a body as a flange 24 Piping 25

Mounting from top l l Model Applicable screw Max. tightning torque Nm l (mm) MGF 40 MGF 63 MGF100 7.5 10 M6 x 1 9 25 M8 x 1.25 9 51 M10 x 1.5 Mounting from bottom 4. Do not bring objects that are sensitive to magnetism near the cylinder. There is a magnet built into the cylinder. Do not bring magnetic disks, cards, or tapes near the cylinder. Data may be lost. 5.

Size: 25, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: D (In-line), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: R5 (5m), Controller: CP1 (PROFINET), Mounting: 7 (Screw Mounting)

Size: 25, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: D (In-line), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: C (w/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: R5 (5m), Controller: CP1 (PROFINET), Mounting: 7 (Screw Mounting)

Size: 25, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: D (In-line), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: R5 (5m), Controller: CP1 (PROFINET), Mounting: 7 (Screw Mounting)

Series: LEY, Size: 25, Motor Mounting Position: Top Side Parallel, Motor Type: G (High Performance Battery-less Absolute, Step Motor, 24 VDC), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 40: 4mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End, Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Parallel, In-line), Actuator Cable Type, Length: R5 (5m), Controller

Series: LEY, Size: 25, Motor Mounting Position: Top Side Parallel, Motor Type: F (High Performance, Step Motor 24 VDC), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 40: 4mm), Stroke: 400mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End, Male Thread; 1 Rod End Nut is Included), Mounting: L (Foot Bracket, Parallel), Actuator Cable Type, Length: None, Controller: C9H (EhterNet/IPâ

A 15 g piece of fluororesin tubing is cut off, washed in deionized water and immersed in 15 ml of 25% methyl alcohol extract at room temperature for 24 hours. Then the extract is diluted with deionized water to be subjected to a quantitative analysis of fluorine ions. The interior of the fluororesin tubing is washed with super deionized water.

(mm) 4 White (W) Burst pressure 3 Black (B) Red (R) 2 Blue (BU) Yellow (Y) 1 Max. operating pressure Green (G) 20 40 60 80 Specifications -20 0 0 Note 1) Fluid Air, Nitrogen gas, Water (Deionized water) Operating temperature C Max. operating pressure (20C) Note 2) 0.7 MPa 10 20 25 30 40 Min. bending radius (mm) Refer to the burst pressure characteristics curve.

factory, list the valve/option with an asterisk () in front of each part number. 1762 Series VFA3000 5 Port Air Operated Valve Specifications 2 position double 2 position single Fluid Air 0.15 to 0.9 0.1 to 0.9 Operating pressure range (MPa) 3 position 0.15 to 0.9 Pilot pressure range (MPa) 2 position double 2 position single 0.1 to 0.9 Base mounted 3 position Ambient and fluid temperature (C)

(mm 2) Applicable for D-sub connector MIL-C-24308 JIS-X-5101 Connector COM specifications (2) Note 1) Value at manifold base mounted, 2 position single operating Note 2) It is available at +COM or COM.

A 15 g piece of fluororesin tubing is cut off, washed in deionized water and immersed in 15 ml of 25% methyl alcohol extract at room temperature for 24 hours. Then the extract is diluted with deionized water to be subjected to a quantitative analysis of fluorine ions. The interior of the fluororesin tubing is washed with super deionized water.

Rotary Cylinder Series MRQ Size: 32, 40 How to Order 32 MRQ B S 50 C A J79W Made to Order or port type Refer to page 343 for the Made to Order details. Nil XF Rc 1/8 G 1/8 NPT 1/8 XN The combination with Made to Order is not available.