The used of turbine oil at temperatures lower than 0C leads to increased viscosity and may cause the valve to malfunction. d n i n i W g c e t i r o i d n e p a t e p i P Leakage Voltage It must be noted that when connecting C-R element parallel to switching element, leakage current flows through C-R element and the leak voltage increases. 2 thread to be left exposed Clamping Torque Switching
Plate Cylinder with Lock Series MLU 25, 32, 40, 50 How to Order Without Auto Switch B 25 30 D F MLU B 25 30 D F J79W S MDLU With Auto Switch Number of auto switches Built-in magnet 2 pcs. 1 pc. "n" pcs.
D-A9/M9/M9W auto switches are shipped together (not assembled). (However, auto switch mounting brackets are assembled when being shipped.) Solid state auto switches marked with are produced upon receipt of order. D-A9V/M9V/M9WV and D-M9A(V)L cannot be mounted. Do not indicate suffix N for no lead wire on D-A3A/A44A/G39A/K39A models.
A B-1 A A-1 B B-2 B A-2 COM-A/COM B-3 COM-B/ A-3 Cable type Nil Robotic cable (Flexible cable) S Standard cable Cable color Connector D terminal no.
Auto Switch Proper Mounting Position (Detection at Stroke End) Solid state auto switch D-M9 Reed auto switch D-A93 C B A Lead wire, in-line entry Values in the table below are used as a reference when mounting the auto switches for stroke end detection. For actually setting the auto switches, adjust them after confirming their operation.
nut (for panel mount) Note 3) V V V V V + Option Note 1) Nr Nil Without pressure gauge V V V V V G Round type pressure gauge (without limit indicator) V Round type pressure gauge (with limit indicator) V V V V M Round type pressure gauge (with color zone) V V V V + b Pressure gauge Note 4) c Set pressure Note 5) Nil 0.05 to 0.7 MPa setting V V V V V 1 0.02 to 0.2 MPa setting V V V V V + d
L4 Note) Weight (g) 5 5.5 6.5 8.5 9.5 19 22 35 38 52 86 95 Model Applicable tubing O.D. d AS1002F-01 AS1002F-03 AS1002F-07 AS2002F-03 AS2002F-07 AS2052F-07 AS2052F-09 AS3002F-07 AS3002F-09 AS3002F-11 AS4002F-11 AS4002F-13 MIN.
To use the power of the product, the total load current must be 200 mA or less. 2.2 Communication specification HRLE Series 2-2 HRX-OM-Z015 Chapter 2 Contact input / output communication Table 2-4 Contact input/output communication terminal number PIN No.
.=514[V] (1F.S.40.010.04[V]) F.S. ( 25[]ON-OFF (1K 1M A/D 5V A/D 5(V)1(M)/(1(k)+1(M))4.995(V)0.005V ) ripple -8No.PS-OMG0005CN-E 20 mm A PSE56 PSE56-28 1 (DC+) (LINE(+)) 2 3 (DC-) 4 (IN15 V) (LINE(-)) A A PSE200/PSE300 (ZS-28-C) 3M 37104-3101-000FL 1473562-4 XN2A-1430 PSE200 PSE300 -9No.PS-OMG0005CN-E DC+ OUT PSE5615V 1 k DCLINE+ PSE56--28 420 mA 500 (24 V ) 100 (12 V ) LINELINE
IDFA Series 6-1 Specifications 6 1 IDX-OM-W016 Air dryer6 References 6-3 Dimensions DRAFT AIR OUTLET IDFA3E B Q A E D AIR INLET VENTILATION WITH LAMP SWITCH AIR OUTLET THERMOMETER EVAPORATION G F C DRAFT AIR INLET DRAIN TUBE (O.D.10 LENGTH:0.8m) VENTILATION (820) J TERMINAL BLOCK N L K M H GROMMET POWER SUPPLY ENTRY(17) P Measuremm Model Thread size A B C D E F G H J K L M N P Q IDFA3E Rc3
Fieldbus interface connector layout BUS OUT: M12 4-pin socket, D-coded (SPEEDCON) No. Designation Description 1 TD+ Transmit Data + 2 RD+ Receive Data + 3 TDTransmit Data 4 RDReceive Data BUS IN: M12 4-pin socket, D-coded (SPEEDCON) No.
[September 2016] D: Contents revised in several places. [April 2017] E: Contents revised in several places.
Exterior dimensions Grommet: G Face seal fitting / compression fitting Terminal part Flat terminal connector 250 Series Model A B Bs C D E F L M P [inch] Grommet: G Grommet: GS Conduit: C Fast on: F DIN terminal: D Terminal: T G H G H G H G H G H J G H J XSA1-2S 22 55 24 63 30 8.5 20 3 8 27 53.5 30 40 47.5 47.5 23 53.5 64.5 45.5 52.5 99.5 47.5 68.5 -2V 50 1/4 XSA2-2S 63 31.5 73.5 63 32.5
connector, PROFINET connection Port1 (XF1), Port type: MDI M12 4 pins socket D-coded connector, PROFINET connection Port2 (XF2), Port type: MDI-X Fig. 3-5 Screw and connector allocation (EX245-SPN3A) 17 No.EX-OMW0011-B 3.2.1.
Suite D Poway, CA 92064 Tel: (858) 679-1903 Fax: (858) 679 1904 SMC Pneumatics Inc. (Indianapolis) 3011 N Franklin Road Indianapolis, IN 46226 Tel: (317) 899 4440 Fax: (317) 898 4808 SMC Pneumatics Inc. (Boston) Zero Centennial Drive Peabody, MA 01960 Tel: (978) 326 3600 Fax: (978) 326 3700 SMC Pneumatics Inc.
D-H7BAL (with indicator light)/Band mount type Bore size (mm) Mounting bracket 16 10 D-H7BAL Auto switch model Foot bracket CJK-L016SUS CJ-L016SUS Wiring type 2 wire Flange bracket CJK-F016SUS CJ-F016SUS Output type T-bracket CJ-T016SUS CJ-T010SUS Applicable load 24VDC Relay, PLC The T-bracket is applicable to the double clevis type (D).
int d: int d: int d: internal diameter of pipe (mm) ernal diameter of pipe (mm) ernal diameter of pipe (mm) ernal diameter of pipe (mm) 8 VN-OMM0001-C Troubleshooting Seek the same trouble from the following table, and take the appropriate countermeasure.
5 Cylinder: Standard/Non-rotating Type Double Acting, Single/Double Rod Series C76 32, 40 How to Order CJ1 C Double acting Single rod K R2 76 J D E C A 32 100 CJP CJ2 C Double acting Double rod W 76 D E 32 100 C JJ B CM2 Auto switch mounting type CG1 Rail mounting Band mounting A B Built-in magnet MB None Built-in magnet Nil D Applicable auto switches and bands are shown on pages 6-10-45
2 Compact Cylinder: Standard Type Double Acting, Single Rod Series CQ2 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 How to Order Without auto switch B 20 30 D CQ2 B 20 30 D J79W S CDQ2 With auto switch Built-in magnet Number of auto switches Mounting style 2 pcs. 1 pc. n pcs.
D-LC05: Lead wire 0.5 m D-LC30: Lead wire 3 m D-LC50: Lead wire 5 m Symbol Shaft type Shaft-end shape Long shaft Short shaft S Single shaft Single at* W Double shaft Single at* Single at J** Double shaft Round shaft Single at K** Double shaft Round shaft Round shaft T** Single shaft Round shaft Y** Double shaft Single at* Long shaft with single at* w Mounting Symbol Mounting B Basic type