441 426 468.5 453.5 496 481 523.5 508.5 551 536 578.5 563.5 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations Station n L1 L2 1571 VPA300/500/700 Series VPA500 Series/Dimensions Type 41/Common exhaust: VV3PA5-411-03 Stations 92.5 2 x 7.2 (For mounting) 30 N.C.

Lead 20: LEKFS40EA Lead 30: LEKFS40EH 20 10 10 0 0 0 100 200 300 400 500 600 0 200 400 600 800 1000 1200 Speed: V [mm/s] Speed: V [mm/s] 5 Model Selection LEKFS Series Battery-less Absolute (Step Motor 24 VDC) SpeedWork Load Graph (Guide) For Battery-less Absolute (Step Motor 24 VDC), Motor Parallel Type * The following graphs show the values when the moving force is 100%.

SY11 A 3 4 0.22 100 kPA to 0.6 100 kPA to 0 M3 x 0.5 M3 x 0.5 Large flow 0 to 0.7 N.C. SY13(A): 15 SY14(A): 26 (14) SY13(A): 13 SY14(A): 24 (12) (1) SY12 3 4 100 kPA to 0 0.14 100 kPA to 0.6 M3 x 0.5 M3 x 0.5 Standard 0 to 0.7 N.O. (1) SY12 A 3 4 0.22 100 kPA to 0 100 kPA to 0.6 M3 x 0.5 M3 x 0.5 Large flow 0 to 0.7 N.O.

Ground the F.G. cable with a resistance of 100 ohms or less +24V Brown +24VDC +24V Power supply Blue 0V 0V 24VDC F.G. Ground the F.G. cable with a resistance of 100 ohms or less Internal circuit PLC INPUT Yellow OUTPUT Maintenance signal Purple Error signal 11 - Doc. no. IZ*-OMT0002 PNP output Shield IZF10R Green F.G.

Symbol Rated pressure range and accuracy Part no. 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC With pressure sensor (0 to 101 kPa, accuracy 2% F.S.) With pressure sensor (0 to 101 kPa, accuracy 1% F.S.) With pressure sensor (100 to 100 kPa, accuracy 2% F.S.) With pressure sensor (100 to 100 kPa, accuracy 1% F.S.)

Press key change 60 to 100. . 10. Press SEL key to set the value. 11. Press key to display d (derivative time). SV PV 12. Press the [SEL] key. SV (The first digit of the lower level will start flashing.) 13. Press key change 11.5 to 20.0. . 14. Press SEL key to set the value. 15. Press key to return to PV/SV display.

476 VVXA21 VVXA22 A 38 49 B 20.5 [17.5] 26.5 [22.5] Model VVXA21 VVXA22 C 10.5 13 D 11 13 E 25 30 F 32 40 G 36 46 H 12 15 N 45 49 [ ]: Individual pressure type J 7 9 K 6.5 8.5 M 54 58 17-3-100 The VX series will be revised shortly.

Positioning complete signal 19 OZ+ Z Z 10 20 COIN OZ+ 14 GND VDC 12 to 24V 13 4.7k COM Torque monitor: Zout 4.7k 12 + IM VDD 30V max. 15mA max. 11 Speed monitor: Zout 4.7k 4.7k SP + 21 CZ Z (Pin 14 is GND.) 26 FG CN I/F 205 Non-standard Motor Compatible Drivers Mitsubishi Electric Corporation Drivers for LJ1, LG1, LX Dimensions (RS-232C without optional unit) Driver 5 100 40 1-5 hole 5

Pressure range Rated pressure Characters displayed on the sub display Vacuum pressure -101.0 kPa Compound pressure 100 kPa Positive pressure 1 MPa Positive pressure 2 MPa Table showing the output mode and output form when Md1 and Md2 are selected.

Pressure range Rated pressure Characters displayed on the sub display Vacuum pressure -101.0 kPa Compound pressure 100 kPa Positive pressure 1 MPa Table showing the output mode and output form when Md1 and Md2 are selected.

Pressure range Rated pressure Characters displayed on the sub display Vacuum pressure -101.0 kPa Compound pressure 100 kPa Positive pressure 1 MPa Table showing the output mode and output form when Md1 and Md2 are selected.

-segments, 7-segments for other) Operation light LED is ON when switch output is ON (OUT1: Orange) Digital filter 4 0, 10, 50, 100, 500, 1000, 5000 ms -62No.PS-OMS0007-H Product No.

Terminal screw (3 positions) Tightening torque 0.2 to 0.25 Nm Housing (Position for light mounting) Terminal block Slot area Grommet type Red (+) Black () Connector part no.: VK300-82-1 Part no. of connector with indicator light Surge voltage suppressor Rated voltage Voltage symbol 100 VAC 100V Part no.

CEP: 09950-350, Brasil TEL: 11-4051-1177 FAX: 11-4071-6636 GREECE (Distributor) S.Parianopoulos S.A. 7, Konstantinoupoleos Street 11855 Athens, Greece TEL: 01-3426076 FAX: 01-3455578 DENMARK SMC Pneumatik A/S Knudsminde 4 B DK-8300 Odder, Denmark TEL: 70252900 FAX: 70252901 COLOMBIA (Distributor) Airmatic Ltda. Calle 18 69-05 Apart.

P PNP C E U 1 C E U 5 AC80120V AC100240V DC24V DC24V NPN RS-232C P PNP RS-232C+BCD NPN P PNP C E 1 R *1) (CE1-ROOC) 05 5m 10 10m 15 15m 20 20m *1)() C ()(CE2)(CE2**-*Z ) CE1-ROOC CE1-RO5 CE1-R10 CE1-R15 CE1-R20 CE1-R*C 11 3 100 200 200 NO 100 80 YES 100 100 80 kgf kgf 63 NO 63 50 50 40 40 YES 100 100 300 300 200 400 500 200 400 500 NO mm/s mm/s OK YES NO NO YES

PP depth element Nominal filtration accuracy: 1 to 75m Material: PP EJ202S ... x 11 (L125) EJ302S ... x 11 (L250) EJ402S ... x 11 (L500) b Set the stopper on the retainer while holding down the V-band outside perimeter, and then tighten the wing bolt to the prescribed position.

shaft indicates the moment point of the cylinder and the load section. 100 1000 Allowable driving force Fn (lbf) Allowable driving force Fn (lbf) 100 10 10 Usable range Usable range 1 0 1 2 3 4 1 0 2 4 6 Distance from cylinder shaft center Lo (inch) Distance from cylinder shaft center Lo (inch) NCY3B25 100 Allowable driving force Fn (lbf) 10 Usable range 1 0 1 2 3 4 5 Distance from cylinder

Without light SY100-61-1 With light Rated voltage Voltage symbol Part number 24 VDC 24 V SY100-61-3-05 12 VDC 12 V SY100-61-3-06 100 VAC 100 V SY100-61-2-01 200 VAC 200 V SY100-61-2-02 110 VAC 110 V SY100-61-2-03 220 VAC 220 V SY100-61-2-04 Without light SY100-82-1 Caution With light Rated voltage Voltage symbol Part number 24 VDC 24 VN SY100-82-3-05 12 VDC 12 VN SY100-82-3-06 100

Description 7 8 9 10 11 12 Material Polyethylene Part no.