SMC Corporation of America
Elite Part Number Search
Search Results "VQD1121U-6LO-M5"

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FSG, Thread: R (or None), Port Size: M5 (M5 x 0.8), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 04 (ø4), Seal: without Sealant

Body Size/Type: 12 (Elbow Size M5), Control Type: 1 (Meter-in), 1: 1, Thread Type: (R Thread or In-Line Type), Port Size: M5 (M5 x 0.8), Applicable Tubing O.D: 06 (ø6)

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 3 (Universal), Control Type: 0 (Meter-out), Model: 1FS, Thread: R (or None), Port Size: M5 (M5 x 0.8), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 04 (ø4), Seal: without Sealant

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 1 (Meter-in), Indicator Direction: 1(180°), Thread: R, Port Size: M5 (M5 x 0.8), Applicable Tubing O.D.: 04 (ø4)

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FS, Thread: R (or None), Port Size: M5 (M5 x 0.8), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 03 (ø5/32"), Seal: without Sealant

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: 0°, Thread: R, Port Size: M5 (M5 x 0.8), Applicable Tubing O.D.: 03 (ø5/32")

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 06 (ø6), Sealant: without Sealant, Push lock: A (Push-lock)

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FS, Thread: R (or None), Port Size: M5 (M5 x 0.8), Width Across Flats: E (8mm), Applicable Tubing: 04 (ø4), Seal: without Sealant

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats [H]: E (8mm), Tube Size: 04 (ø4), Sealant: without Sealant, Push lock: A (Push-lock)

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 3 (Universal), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 06 (ø6), Sealant: without Sealant, Push lock: A (Push-lock)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, COMPACT, CONNECTOR (DC), VALVE, VQ100 SOL VALVE 3-PORT, 1B, VQ100 OTHER SIZE RATING, .02640 lb

The SYJ Valve is an innovative combination of space efficiency and performance superiority which provides real value to the design solution. Whether designed in a manifold or used as a single valve, this small profile increases design flexibility and minimizes space requirements. The SYJ valve utilizes a low power (0.5 watts standard) pilot solenoid design, which dramatically reduces thermal

VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the VQD1000 valves that are in contact with fluid are all copper free. The VQD series offers a remarkably quick and stable response time. Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum

This is a legacy product, and replaced byVQZ235-6LO1, VALVE, BASE MOUNT (DC) *LQA, VALVE, VQZ200 VALVE, SOL 3-PORT, 2A, VQZ200 NO SIZE RATING, .13200 lb

VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm

VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm

Series VQZ base mount solenoid valves combine convenience with durability and performance in a more traditional mounting style. Series VQZ Body Ported Solenoid Valves combine flexibility with high performance and long life in an inline body style. Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (

VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm