(Symbol F: G1/2, Symbol N: NPT1/2) Overow port Rc1 (Symbol F: G1, Symbol N: NPT1) Fluid contact material Stainless steel, Copper (Heat exchanger brazing), Brass, Bronze, PTFE, PU, EPDM, PVC, NBR, PE, NR, PBT, PP , POM, Carbon, Ceramic Electrical system Power supply 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) Allowable voltage range 10% (No continuous voltage uctuation) Applicable
/Japanese 1 pc.), Operation Manual (for installation/operation) 2 pcs. (English 1 pc./Japanese 1 pc.), Y-strainer (40 meshes) 25A, Barrel nipple 25A, Anchor bolt xing brackets 2 pcs.
RoHS Desktop Duster Box ZVB Series IZS How to Order IZN A S B ZVB 20 IZF ZVB ZVB q w e r t IZD IZE w Additional air blow B With additional air blow e Photoelectric sensor Nil None Note 1) S With photoelectric sensor Note 2) r AC adapter q Size Note 1) It is necessary to connect an external switch to the external input terminal on the back side of the product.
Deionized water: Electric conductivity 1 S/cm or higher (Electric resistivity 1 Mcm or lower) 3 q Ambient temperature: 32C, w Circulating fluid: Tap water, e Circulating uid temperature: 20C, r Circulating uid ow rate: Rated ow, t Power supply: 460 VAC 4 q Ambient temperature: 32C, w Circulating fluid: Tap water, e Circulating uid ow rate: Rated ow, r Power supply: 460 VAC 5 q Ambient temperature
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1U (PVDF, 1/4-28UNF), Option: 2 (Manual Override)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: E (Plate: PFA; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1U (PVDF, 1/4-28UNF), Option: 2 (Manual Override)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1U (PVDF, 1/4-28UNF), Option: 2 (Manual Override)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: F (Plate: PFA; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 2U (PFA, 1/4-28UNF), Option: 2 (Manual Override)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1U (PVDF, 1/4-28UNF), Option: 2 (Manual Override)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 2U (PFA, 1/4-28UNF), Option: 2 (Manual Override)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1 (PVDF, M6), Option: 2 (Manual Override)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 2 (PFA, M6), Option: 2 (Manual Override)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 2U (PFA, 1/4-28UNF), Option: 2 (Manual Override)