SMC Corporation of America
Elite Part Number Search
Search Results "AC30A-03C-V-D"

Process Valve: 2 Port Valve For Flow Control VNB Series [Option] Electrical entry: D or DZ only. How to Order Pilot system option Seal material Body material option Nil V Standard Vacuum pilot type NBR seals FKM seals EPR seals Nil Standard A B C Bracket (valve size: 1/2/3/4.)

(Hexagon width across flats) Applicable tubing O.D. d A L4 L4 A L3 D1 D1 L3 M D2 L2 L1 M T D2 L2 L1 T Metric Size Min.

N.C. -14No.PS-OMU0012-C Internal circuit and wiring example Setting of NPN open collector 2 outputs: Pressure sensor 3-wire type Max. 30 V, 20 mA Residual voltage: 1 V or less Setting of PNP open collector 2 outputs: Pressure sensor 3-wire type Max. 20 mA Residual voltage: 1 V or less Setting of NPN open collector 2 outputs: Pressure sensor 2-wire type Max. 30 V, 20 mA Residual voltage: 1

Use this data as a guideline for selection, as the performance data may vary depending on the material and size of the work piece. 1) Discharge characteristics (Discharge time from 1000 V to 100 V) 2) Discharge characteristics range (Discharge time from 1000 V to 100 V) 25 2 Air flow scale: 1 Air flow scale: 2 1 20 3 Air flow scale: 3 Discharge time [s] 15 s 10 5 4 Air flow scale: 4 0 0 300

V SY SYJ V SX V Installation Insert the cover straight onto the pilot assembly making sure not to contact the pilot valve and lock into place. VK Lever Connector VZ O ring Light cover VF Caution VFR Internal Wiring Specifications VP7 Caution VP4 Changing the Pilot Valve (+) + () SOL V Removal of Pilot Valve 1. Light ass'y ZNR VQ Remove the light cover.

Yes Grommet 3-wire (NPN) Diagnostic indication 2-color indication 5V, 12V IC circuit 3-wire (PNP) 12 V 2-wire A96 A93 A90 A96V A93V A90V 5 V IC circuit 3-wire (NPN equivalent) Yes 100 V 12 V Grommet Relay, PLC 2-wire 24 V 5 V, 12 V IC circuit 100 V or less Solid state auto switches marked with are produced upon receipt of order.

Designation Description 3 Setting the Number of occupied stations Power supply connector Power supply with load voltage for valves and operating voltage for SI unit (M12 5-pin plug, B-coded) 3 1 SV24 V +24 V for solenoid valve Setting Station No. 4 5 2 2 SV0 V 0 V for solenoid valve x10 x1 4 Ground terminal Functional earth (M3 screw) 3 SI24 V +24 V for SI unit operation 0 0 Error (Default

Output specification/Temperature sensor Integrated display R Symbol OUT1 OUT2 Temperature sensor Flow rate Flow rate Temperature NPN PNP Analog 1 to 5 V Analog 4 to 20 mA Analog 1 to 5 V Analog 4 to 20 mA A B C D E F G H AT BT CT DT ET FT NPN PNP Analog 1 to 5 V Analog 4 to 20 mA Analog 1 to 5 V Analog 4 to 20 mA External input Note 1) NPN PNP NPN NPN PNP PNP NPN PNP NPN PNP NPN NPN PNP PNP

V Yes Grommet 3-wire (NPN) IC circuit 5 V, 12 V Diagnostic indication (2-color display) 3-wire (PNP) 2-wire 12 V 3-wire (NPN) IC circuit 5 V, 12 V Water resistant (2-color indication) M9PA M9PAV 3-wire (PNP) M9BA M9BAV 2-wire 12 V Although it is possible to mount water resistant type auto switches, note that the rotary actuator itself is not of water resistant construction.

Meaning 1 +15 V 1 +15 V 2 2 Sensor input 3 GND 3 GND 4 Sensor input 4 Sensor input PCA-1557785 Pin No. Meaning Pin No. Meaning 1 +15 V 1 +15 V 2 Sensor input 2 Sensor input 3 GND 3 GND 4 Sensor input 4 Sensor input 5 Unused 5 Unused -11No.SFOD-OMS1007-A Operation details Power ON The power turns ON when the button is pressed.

Size Rated Rated Rated (to be onnected of leak current voltage current to the user's current equipment) Plug with ground HRSE012-A-10 3 cores x terminal (JIS C8303 Plug for the eceptacle for 15A and 125 V with dipole grounding electrodes) HRSE012-A-10-T 14AWG Shared 15mA 1-phase HRSE018-A-10 (3 cores x 2.0mm2) with 100 100V AC 15A 15A or V and 200 V (50/60Hz) 30mA (including HRSE018-A-10-

Port size D 1: Refer to the PF2A3 /PF2W3 operation manual for details of the flow monitor. 3: Load indicates analogue input equipment such as an ammeter.

Externally set input impedance 100 k or more Externally set input voltage 0 to 5 V 1 8 External potentiometer 10 k ( W or more): not provided Step response 0.06 s or less (1 A, 95%) Dither frequency adjustable range (DITHER) 120 to 180 Hz (140 Hz when delivered) 0 to 500 mA (0 mA when delivered) Zero adjustable range (NULL) 500 mA to 1 A for input voltage 5 V (1 A when delivered) Gain adjustable

Conduit Current Type 2-wire: 4-20mA Current Type 2-wire: DIN cuffir tp6 2-'n6 qr: rlplr .rsmr and por alpdy or {-2oln^l Voltage 3-wire: 0-5V,0-10V Input impedance: 30(KQ) Voltage 3-wire: Input signal oI 0-5,0-10(V) Power supply of 12-15(V) xPlease be sur !

(mm) Model Model Accessory TM-04 TM-06 TM-08 2 x 6 TM-04 TM-06 TM-08 TM-10 TM-12 4 6 8 10 12 2.6 x 8 4 TM-10 3 x 8 TM-12 Dimensions: Multi-tube Holder N x D (Pitch) N x holding part Cutting groove for separation N (No. of holding parts) Applicable tubing O.D.

Flame Resistant (Equivalent to UL-94 Standard V-0) FR Soft Nylon Tubing Series TRS Suitable for air and water piping in environments where sparks from spot welders, etc., may be a problem. Flame resistant tubing Model/Specifications 20 m roll 100 m reel TRS0603 TRS0805 TRS1065 TRS1208 Model Tubing O.D. (mm) 6 8 10 12 Tubing I.D.