10 20 Cooling system Natural air cooling Operating temperature range [C] Note 6) Screw mounting: 0 to 40 (No freezing) Screw mounting: 0 to 30 (No freezing) Operating humidity range [%RH] Note 7) 90 or less (No condensation) Insulation resistance [M] Between the housing and SG terminal: 50 (500 VDC) Weight (including batteries) [g] 410g (Screw mounting) 430g (DIN rail mounting) Note 1) Do
Do not disassemble the trunnion style. Seal kit includes a grease pack (40, 50: 10 g, 63, 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 39
Do not replace the bushings. The bushings are press-fit. To replace them, they must be replaced together with the cover assembly. 2. To replace a seal, apply grease to the new seal before installing it. If the cylinder is put into operation without applying grease to the seal, it could cause the seal to wear significantly, leading to premature air leakage. 3.
Do not replace the non-rotating guide. Since the non-rotating guide is press fitted, the entire cover assembly needs be replaced instead of a single part. 200
Do not replace the non-rotating guide. Since the non-rotating guide is press fitted, the entire cover assembly needs be replaced instead of a single part. 202
Do not disassemble the trunnion style. Seal kit includes a grease pack (40, 50: 10 g, 63, 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 35
CA2H100A-PS Do not disassemble the trunnion style. Seal kit includes !4, !5 and !6. Order the seal kit based on each bore size. Seal kit includes a grease pack (40, 50: 10 g, 63: 20 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 40
Piston seal NBR Cushion valve seal NBR O-ring MBW100-PS Cylinder tube gasket NBR Do not disassemble the trunnion style. Seal kit includes !2, !3, !4 and !6. Order the seal kit based on each bore size. Seal kit includes a grease pack (40, 50: 10 g, 63, 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed.
CA2WH100A-PS Do not disassemble the trunnion style. Seal kit includes !0, !1 and !2. Order the seal kit based on each bore size. Seal kit includes a grease pack (40, 50: 10 g, 63 or more: 20 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 41
Do not replace the bushings. The bushings are press-fit. To replace them, they must be replaced together with the cover assembly. 2. To replace a seal, apply grease to the new seal before installing it. If the cylinder is put into operation without applying grease to the seal, it could cause the seal to wear significantly, leading to premature air leakage. 3.
Do not replace the bushings. The bushings are press-fit. To replace them, they must be replaced together with the cover assembly. 2. To replace a seal, apply grease to the new seal before installing it. If the cylinder is put into operation without applying grease to the seal, it could cause the seal to wear significantly, leading to premature air leakage. 3.
Note 4) When using the D-M9lA(V) or Y7BA, do not use the steel set screws which are included with the above auto switch mounting brackets (BA7-lll, BA4lll). Order a stainless steel screw kit (BBA1) separately, and use the M4 x 6 L stainless steel set screws included in the BBA1. Note 5) There is a difference in the cylinder tube thickness depending on the cylinder model.
When washing the element, do not wipe it using a stiff brush or rag.
Additionally, do not put the tube end in the liquid. This may cause the back pressure to be applied, resulting in poor performance. 3.Liquids cannot be collected by the air. 1076 A
. * If the step motor and servo motors do not meet your specifications, also consider the AC servo specification (Page 46). 38 Model Selection LEF Series Step Motor (Servo/24 VDC) Servo Motor (24 VDC) Clean Room Specication For the LECPA, refer to page 40.
When this is done, take care that the coverings of the lead wires do not enter the core wire crimping area. Use special tool when crimping. (For the crimping tool, please consult with SMC.)
Do not use a tool when rotating the handle. When the handle is rotated with a tool, it may apply excessive torque to the handle or inside the valve body and it may cause damage. Rotate the handle by hand. 9. When locking the valve with LOTO feature in the closed position, use safety lockout hasp.
Do not use a tool when rotating the handle. When the handle is rotated with a tool, it may apply excessive torque to the handle or inside the valve body and it may cause damage. Rotate the handle by hand. 9. When locking the valve with LOTO feature in the closed position, use safety lockout hasp.
(To set the pressure, do so in the direction of pressure increase.) 2. Set the outlet pressure to 85% or less of the inlet pressure. Precautions Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 387 to 391 for Precautions on every series. Inlet pressure (MPa) Mounting/Adjustment Warning 1.
(To set the pressure, do so in the direction of pressure increase.) Pressure gauge and One-touch fittings 1. Both the pressure gauge and the One-touch fittings are a cassette type, so that it is possible to rotate them freely. Rotate them after confirming that there is no pressure inside and exhausting air completely. 714