MXS 6 MXS 8 MXS12 MXS16 MXS20 MXS25 4 5 5.5 6 10 13 0.9 0.9 2.1 4.4 4.4 7.4 M3 X 0.5 M3 X 0.5 M4 X 0.7 M5 X 0.8 M5 X 0.8 M6 X 1 Bottom screw Do not rotate Piston rod Precautions for Adjuster Option Stroke adjuster Do not damage. Caution eShock absorber is considered a consumable component. When energy absorption is decreased, replace it.

Do not service or attempt to remove product and machinery/equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.

The condition of the lock monitor and the detection signal from the lock unit auto switch do not directly confirm the locking condition at the piston rod, but confirm this indirectly from the position of the brake piston.

When locked, do not apply impact loads, stroke vibration or rotational force, etc. This may damage the locking mechanism, shorten the service life or cause unlocking malfunction. 6. When an air cushion is used, operate the cylinder to the stroke end.

Also, do not use the filter when these chemicals are present in the atmosphere. G !1Check valve Note 8) !2 Fitting (V port) Note 9) Nil K None Part no. Applicable tubing O.D.

Do not use the cylinder as a shock absorber. Using the cylinder as a shock absorber may cause damage. 2. Do not open the cushion valve beyond the stopper. As a retaining mechanism for the cushion valve, retaining ring is installed, and the cushion valve should not be opened beyond that point.

Do not use it in such a way that excessive external force or impact force could work on it. This could result in damage.

. * Products with tiny scratches, smears, or display color or brightness variations which do not affect the performance of the product are verified as conforming products.

(If you do not cycle the power, it does not register the data in the driver.) Note2) Selected Items Write: It writes the specific parameter values of the corresponding frame to the driver. Single Axis Write: It writes all of the parameters to the driver. Note3) Do not change For manufacturer setting parameters.

Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.

Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.

Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.

MHS2-32D MHS2-40D Q 11 12 RA 38 44 SA 4.5 5.5 FX 23 26.5 G 30.5 32 AA 44 47 NA 14 16 J 20 21 AB 41 44 L 2H9 3H9 B 56 62 DO 64 70 DC 56 62 EO 24 28 EC 16 20 CA 8 9 CB 16 17 FY 20.5 23.5 FZ 5 6 +0.025 0 +0.025 0 Model MHS2-32D MHS2-40D UA M5 x 0.8 M6 x 1 UB 10 12 VA VB 3 4 WA XA XB 3 4 SB 8 9.5 +0.025 0 +0.030 0 +0.025 0 +0.030 0 +0.062 0 +0.062 0 34H9 3H9 4H9 3H9 4H9 42H9 6 Series MHS 2

Do not drop, dent, or allow excessive impact to cylinder during handling. 5, Keep at least 20mm away from each other when 2 or more cylinders with high magnetic field resistance auto 3. switch are mounted in parallel. up, although the auto switch will function. Do not exceed specified current or the LED might be damaged and not functjon.

Do not connect. Do not connect. Connect to actuator power line (Yellow) Connect to actuator power line (Red) Connect to actuator power line (Blue) Connect to actuator power line (Orange) Connect to actuator power line (Black) Connect to actuator power line (White) When an alarm occurs, this signal turns off the alarm after the cause is resolved.

T-slots l Model Bolt Max. tightening torque Nm Max. screw-in depth (l mm) LXP M5 x 0.8 7.4 8.5 Use bolts at least 0.5mm shorter than the maximum screw-in depth, so they do not touch the body.

1 Q=226S P(P2+0.1013) Sonic flow : P1+0.1013 1.89(P2+0.1013) Do not use in an explosive environment. 2 Q=113S(P1+0.1013) Q : Flow rate [ /min(ANR)] S : Effective area (mm2) P : Differential pressure (P1-P2) [MPa] P1 : Upstream pressure [MPa] P2 : Downstream pressure [MPa] Do not use in locations subject to heavy vibration and/or shock.

Do not operate the CS1 series at twice the output. Applicable Series Series Description Note Vol. no.

Prevention of electric shock and fire Do not operate the switch with wet hands. Also, do not operate the Thermoelectric Bath with water or fluid left on it. 2. Action in the case of error If any error such as abnormal sounds, smoke, or bad smell occurs, cut off the power at once, and stop supplying facility water.