Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 5 Port/Body Ported Common SUP Common EXH, Stations: 18 Stations, A B Port Size: -, P R Port Thread: -
Bore size(mfn) Standard stroke(mm) MGOftl Slide bearing MGor12, rc 10, 20, 30, 40, 50 MGOr2o,2s 20, 30, 40, 50, 75, 100 25, 50, 75, 100 MGOL Ball bush bearing MGOr32,40, 50, 63, 80,1OO . intermediate stroke As to intermediate stroke (5, 10, 15, 20, 30, 35 )' spacer of 5, 10' 15,20mm width will be used (Example) MGOM50-10 is produced by installing 1smm spacel in MGQM50'25 Consult factory when
N4-18 NCQ2, Series NCQT 200 PSI (14 kgf/cm') -20-150.F (-25 -65"C) 2 20 inch/sec (50-500mm/sec) FEATURES 1) The NCQT Series cylinder gives a shorter, lighter and more compact package for a given stroke. 2) The unique shape enables the use of rail-mounted switches without significantly increasing the overall length. .
PA07 . 17 4.6 Auto tuning modePr.PA08 . 18 4.7 Input signal automatic on selectionPD01 . 18 4.8 Parameter setting by MR Configurator2TM . 19 4.8.1 Parameter reading . 20 4.8.2 Parameter setting (Ex. Control mode change) . 20 5.
NO.ZK2-OM00801-B // ZK2-ZSV-A A 2 9 10 11 14 14 15 16 16 17 17 20 20 20 F0 22 F1 OUT1 23 F2 OUT2 25 F3 27 F4 28 F6 30 F11 31 F80 32 F81 33 F90 34 F96 36 F98 37 F99 39 40 B 43 44 45 51 52 52 -1NO.ZK2-OM00801-B (ISO/IEC)(JIS)1)2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems.
-2No.PS-OMV0008CN-E / *3) 1 1.5 3) 1 1 () [] -3No.PS-OMV0008CN-E () () () () -4No.PS-OMV0008CN-E () * UL UL1310 2 UL1585 2 30 Vrms(42.4 V ) (2 ) UL (1 20 ) (ISE7G-T-ZS-48-A) N G -5No.PS-OMV0008CN-E Al2O3(96)C3604+FKM () O 1 /min 16MPa () * FG (35 N () ,() *() 6 33 -6No.PS-OMV0008CN-E () () 20 m DC(-)() * () () CE -5~70-5~50(5 ) (FKM) Al2O3()C3604()( ) -7No.PS-OMV0008CN-E
Altitude Up to 3000 m This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
N4-18 NCQ2, Series NCQT 200 PSI (14 kgf/cm') -20-150.F (-25 -65"C) 2 20 inch/sec (50-500mm/sec) FEATURES 1) The NCQT Series cylinder gives a shorter, lighter and more compact package for a given stroke. 2) The unique shape enables the use of rail-mounted switches without significantly increasing the overall length. .
(Writing time: 10,000 times, Data duration: 20 years after power off) A ceramic diaphragm is used as the pressure sensor for this product. The ceramic diaphragm can be damaged by overpressure from hydraulic shock. This can be the result of several situations such as system fill or sudden changes in flow sometimes called water hammer.
Ce priphrique a galement t valu et dmontr conforme aux limites d'exposition aux RF d'IC dans des conditions d'exposition des appareils mobiles (antennes sont suprieures 20 cm partir du corps d'une personne). When product comply with IFETEL inquire below warming statement has to be contained in user manual.
Note 2) D-M9 and A9 type cannot be mounted on square groove of the CP96N series. 19 - Auto switch proper mounting position (Detection at stroke end) 20 - 3-4. Wiring method and examples of auto switches 21 - 4. Maintenance 4-1. Consumable parts Fig. 9 Replaceable seals 4-1-1. Seal kit Bore size (mm) Order No.
.CN4 . 21 6.1 . 21 1 - 6.2 . 21 6.3 . 22 . 23 7.CN3 . 24 8.CN1IF (CONT) . 25 8.1 . 25 8.2 . 27 9.CN2TB/PC . 28 9.1 . 28 10.LED . 29 10.1 LED . 29 10.2 IF LED . 29 11. . 30 11.1 . 30 11.2 . 30 11.3 . 30 11.4 . 32 12. . 33 12.1 . 33 12.1.1 . 39 12.2 IF ( ) . 40 12.3 (IO ) . 41 12.4 . 43 13.
Analogue output Output impedance approx. 1 k Output current (rated pressure range) 4 to 20 mA 2.5%F.S. 2.4 to 20 mA Current output 3 2.5%F.S. Linearity 1%F.S.
VP3185DZA1-X81 MAX.10 160.3 6 140 87.4 26.5 EXH.1 56 76 81 EXH.2 105 (Non-locking) Manual override Applicable cable O.D. 6 to 8 Pg9 Rc 1/4 Pilot EXH 2-Rc 1/8 (External pilot port) 2-13 Mounting hole EXH 243.1 250.7 PA PE 159 166 150 140 105 90 IN EXH OUT 62 52 25 (EXH port) Rc 2 118 41 41 2-Rc 1 1/4, 1 1/2, 2 (IN, OUT port) When B spec. of -X81 (N.O. spec.), VF3140 solenoid has to be positioned
, 30, 40, 50 20, 30, 40, 50, 75, 100 MGOL /tO, 50, 63, 80, 1OO 25, 50, 75, 100 As to inremedrale slroke (5, 10, 15,20,30 35.. .. ), spacer ol5, 10, 15 20mm wdth wllbe used (EEmple) MGQM5o lO s produced by instaling 15mn spacer in MGQ'!
Operating signal During operation: contact close, During stop: contact open Error signalDuring error: contact close, During stop: contact open Contact capacityRated load voltage: 240 VAC or less/24 VDC or less Max. load current: 5 A (Resistance load)/2 A (Induction load) Min. applicable load: 20 VDC, 3 mA Power supply voltage is applied to the remote operation contact.
SPECIFICATIONS Model AR20K-B AR25K-B AR30K-B AR40K-B AR40K-06-B AR50K-B AR60K-B Port size 1/81/4 1/43/8 1/43/8 1/43/81/2 3/4 3/41 1 1/8 Gauge port size Note1) Air Fluid Ambient and fluid -5 60 (Should be no freezing) temperature 1.5 MPa Proof pressure 1.0 MPa Max. operating pressure 0.05 0.85 MPa Set pressure range Note2) Relieving type Construction Mass kg 0.16 0.21 0.29 0.44 0.47 1.17
Conditi on Inlet Air Temperature 100 F (37.8C) Ambient Temperature 100 F (37.8C) Voltage 115V 60Hz Working Fluid Compressed Air Operating Range Inlet Air Temperature 41-122 F (5-50C) MIN.
R 3/8 32.9 32.9 39.4 KKA4P-02M 17 R 1/4 28.3 36.2 42.2 -03M 1/4 R 3/8 18.9 6.9 26.4 36.6 36.7 43.2 T A -04M 22 R 1/2 65.9 38.2 46.2 KKA6P-03M R 3/8 60.3 40.6 47.1 24 -04M 1/2 R 1/2 20.4 10.0 54.2 69.2 39.9 47.9 -06M 30 R 3/4 119.0 40.4 49.9 KKA7P-04M R 1/2 173.9 58.1 66.3 32 -06M 3/4 R 3/4 27.6 13.5 99.6 209.6 59.9 69.4 L2 H -10M 36 R 1 275.0 59.5 69.9 L1 KKA8P-06M R 3/4 362.8 73.4 82.9 41
SWITZERLAND (41) 052 396 31 31 Dorfstrasse 7, CH-8484, Weisslingen, Switzerland Diagnostic Step 3 Connection to PLC UNITED KINGDOM (44) 0845 121 5122 Note) Refer to the operation manual of the PLC manufacturer for connection to PLC and Configurator.