SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-32-02-N3T"

Series VVX31/32/33 Normally Closed (N.C.), Normally Open (N.O.), Common (C.O.)

When demanding 32-bit data, specifying the lower 16-bit code No. and turning RYn8 to ON sets the lower 16-bit data to RWwn 5 and the upper 16-bit data to RWrn 6. Data is stored in the RXn8. RXn8 turns on at the same time.

DOUT1 ALARM CODE(Alternately displayed) Select the alarm No. to be allocated to Contact output signal 1 Setting rangeAL.01AL.32(Initial valueAL.01) HRR Series 2.4 Setting and checking 2-7 HRX-OM-W004 Chapter 2 Contact input/output communication Contact output signal 1 Select maintenance 11. Press the [] key.

OUT 28. 3 4. 99 10. 7 16. 3 3 6 3. 5 IN OUT 78. 5 16. 7 32. 4 48. 1 10 4 6. 9 IN OUT 201 45. 6 86.3 126 16 6 15 IN OUT 314 73 136 199 20 8 21 IN OUT 491 119 218 316 25 10 28 IN OUT 804 207 368 529 32 IN 12 34 Note) Prevent load from being applied to the piston rod when the piston rod is being retracted. d) Spring extended type [C(D)U(K)*-*T] (N ) Operating pressure Mpa Pressure receiving

Series S0700 Slim Compact Plug-in Manifold Bar Base kit (SerialTransmission) EX180 (For Output) SerialTransmission System S How to Order Manifold SS0751 08 C4 C8 Stations Symbol Stations Option 02 2 station Symbol Specifications None Nil D D0 Dl K Note 2) 32 Note) 32 stations With DIN rail (Rail length: Standard) Note) The maximum number of stations will be different depending on the wiring

When demanding 32-bit data, specifying the lower 16-bit code No. and turning RYn8 to ON sets the lower 16-bit data to RWwn 5 and the upper 16-bit data to RWrn 6. Data is stored in the RXn8. RXn8 turns on at the same time.

The models VX31/32/33 have been revised. For details, please refer to catalog no. ES70-26A. Similar updating for other VX series are scheduled to follow shortly. Series VX Solenoid Coil Assembly How to Order VX021 C 001 01 B Rated voltage (1) VX solenoid coil assembly 02 =+4 7> 01 =+4 7> Electrical option Application 03 =+4 7> Nil # 04 =+4 7> S 5 % * ,* -> -/& 05 ( !

Class attribute ID Access rule Description Value 2 Get Max Instance 32 6-2. Class common service Service code Description 0Eh Get_Attribute_Single 6-3.

5 x 1.5 t5 73.2 36 32 0.28 5t427fi( It_433?96(tR)0tMl.0[l 25.0 38 30 M27x3 t3.2 36 32 0.28 A dimensions in millimeters. Notes: 1. To be lsed wth non-button models on y. 2. Max mum sideoad angle is 30'. I 6ffi. Adjustable Hydraulic Series lmperial Accessories JAM NUT (JN) fttolog llo. P.rt trrbo/ ljlodel 0el) lA JI JH Wsighl [.rJ Jlllill0xl J?44?

The series is available in base mounted or body ported styles.Bar stock type manifold for SYJ3000 valves, Supply and exhaust ports common (20, 31, 32, 41 types), Valves individually wired, Maximum 20 stations available as standard, 5 port sizes available, "MFLD, 4/5 PORT SOLENOID VALVE

EX260-SPN1/2: SI unit with 32 outputs, EX260-SPN1 or EX260-SPN2 This SI unit can be used with both firmware version 1.0.0 and 2.1.1 1, but the MRP function is not available. EX260-SPN1/2 MRP: SI unit with 32 outputs and MRP function, EX260-SPN1 or EX260-SPN2 This SI unit can be used with firmware version 2.1.1 1. This SI unit cannot be used with firmware version 1.0.0.

DIN terminal: VKF334-D-01 Base mounted Grommet: VKF334-G-01 33.5 16.7 26 4 Manual override (Non-locking) A 12.7 20 10 18.5 20.5 3 32 71.5 MAX.10 2-4.3 (Mounting hole) Applicable cable O.D. 4 to 6.5 48.5 300 26 4 Pg.7 3 27 (Lead wire length) Manual override (Non-locking) A 20.5 18.5 mPm 3 32 59 68 78 70.5 43.5 12 7.5 P R 7.5 12 43.5 13.5 11 33.5 P R 13.5 11 Refer to grommet type for other

Grommet: VKF334-G-01 DIN terminal: VKF334-D-01 Base mounted type 33.5 16.7 26 4 Manual override (non-locking) A 12.7 20 10 18.5 20.5 3 32 71.5 Max. 10 2-4.3 (mounting holes) Applicable cord O.D. 4 to 6.5 48.5 Approx. 300 (lead wire length) 26 4 Pg.7 3 27 Manual override (non-locking) A 20.5 18.5 3 32 59 68 78 70.5 43.5 12 7.5 P R 13.5 11 33.5 7.5 12 43.5 P R 3-Rc(PT) 1/8 (ports P, A, R) 13.5

. -7No.EX-OMP0013-E Model Indication and How to Order EX260-SEN 1 Connector type, output specification 1 M12 connector, 32 outputs, PNP (negative common) / source 2 M12 connector, 32 outputs, NPN (positive common) / sink 3 M12 connector, 16 outputs, PNP (negative common) / source 4 M12 connector, 16 outputs, NPN (positive common) / sink Fieldbus EN EtherNet/IPTM -8No.EX-OMP0013-E Summary

No jump destination 32 No label found at the program designated jump destination. Nesting exceeded 33 Sub-routine nesting (calling a sub-routine from another sub-routine) exceeds 14 levels. No return destination 34 No return destination found for the RET command operation. Executing FOR 35 A forbidden command is found between FOR and NEXT.

(mm) 02 04 2 4 Nil -X19 With lock ring Without lock ring (10 or larger) 1 2 10 to 16 20 to 32 ZX 06 6 3 40, 50 ZR 08 8 Material 10 10 N S NBR Silicon rubber 13 13 ZM 16 16 Pad type U Urethane rubber 20 20 ZH F Fluoro rubber 25 25 U C Flat Flat with ribs GN Conductive NBR (2 to 16) 32 32 ZU GS Conductive silicon rubber (2 to 16) 40 40 D Deep 50 50 20 or large are manufactured upon receipt

Mounting bracket Minimum order quantity Bore size [mm] Contents 20 25 32 40 Mounting nut (M5, Rc1/8, NPT1/8) 1 1 JSN-020B JSN-032B JSN-040B 1 mounting nut Rod end nut 1 NT-02 NT-03 NT-04 1 rod end nut Refer to page 10 for dimensions. 1 Can be used for M and MZ only.

74 9.3 17 32 74 CRBU2 1.5 MPa Allowable surge pressure CRB1 Within 1 Backlash (2) + 4 0 MSU Tolerance in rotating angle Note 1) Output under the operating pressure of 0.5 MPa.

Symbol Graph (1) VND 02 D Pilot Pressure (N.O. type) Valve type Valve size N.C. N.O.

74 9.3 17 32 74 CRBU2 1.5 MPa Allowable surge pressure CRB1 Within 1 Backlash (2) + 4 0 MSU Tolerance in rotating angle Note 1) Output under the operating pressure of 0.5 MPa.